Performance evaluation of carbon quantum dots impregnated glass ionomer cement to avoid peri-implant disease
- 29 April 2024
- journal article
- research article
- Published by IOP Publishing in Biomedical Materials
- Vol. 19 (3) , 035040
Abstract
Dental cement residues exacerbate peri-implant tissue irritation and peri-implantitis. The present study aims to evaluate the cytotoxicity, physiochemical, optical, and rheological properties of carbon quantum dots (CQDs) impregnated glass ionomer cement (GIC). Surface passivated fluorescent CQDs were synthesized using citric acid via thermal decomposition and blended with GIC. Characterization studies and rheological measurements were made to evaluate their performance. 3D-printed dental implant models cemented with GIC and GIC-CQD were compared to analyze excess cement residues. MTT assay was performed with human dental pulp stem cells (hDPSCs) and statistically analyzed using ANOVA and Tukey’s test. CQDs with a particle dimension of ∼2 nm were synthesized. The amorphous property of GIC-CQD was confirmed through XRD. The fluorescence properties of GIC-CQD showed three times higher emission intensity than conventional GIC. GIC-CQD attained maturation with a setting time extended by 64 s than GIC. Cement residue of size 2 mm was detected with a UV light excitation at a distance between 5 to 10 cm. Biocompatibility at 0.125 mg ml−1 dilution concentrations of GIC-CQD showed viability greater than 80% to hDPSCs. For the first time, we report that CQDs-impregnated GIC is a unique and cost-effective strategy for in-situ detection of excess cement rapidly using a hand-held device. A novel in-situ rapid detection method enables the dentist to identify residual cement of size less than 2 mm during the implantation. Therefore, GIC-CQD would replace conventional GIC and help in the prevention of peri-implant diseases.Keywords
This publication has 40 references indexed in Scilit:
- A Comprehensive Review of Peri-implantitis Risk FactorsCurrent Oral Health Reports, 2020
- Current state‐of‐the‐art and future perspectives of the three main modern implant‐dentistry concerns: Aesthetic requirements, mechanical properties, and peri‐implantitis preventionJournal of Biomedical Materials Research Part A, 2019
- Peri‐implant healthJournal of Periodontology, 2018
- Molecular structural analysis of hydrated ethylene glycol accounting for the antifreeze effect by using infrared attenuated total reflection spectroscopyJournal of Molecular Liquids, 2016
- Laser fluorescence detection of subgingival calculus using the DIAGNOdent Classic versus periodontal probingLasers in Medical Science, 2016
- Cytotoxicity of modified glass ionomer cement on odontoblast cellsJournal of Materials Science: Materials in Medicine, 2016
- Radiographic detection and characteristic patterns of residual excess cement associated with cement-retained implant restorations: A clinical reportThe Journal of Prosthetic Dentistry, 2012
- Use of NIR light and upconversion phosphors in light-curable polymersDental Materials, 2012
- Measuring and interpreting point spread functions to determine confocal microscope resolution and ensure quality controlNature Protocols, 2011
- Preparation of new glass systems by the polymeric precursor method for dental applicationsJournal of Non-Crystalline Solids, 2004