Quantitative investigation of the edge enhancement in in-line phase contrast projections and tomosynthesis provided by distributing microbubbles on the interface between two tissues: a phantom study
Authors:
Open Access
- 21 November 2017
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (24) , 9357-9376
Abstract
The objective of this study was to quantitatively investigate the ability to distribute microbubbles along the interface between two tissues, in an effort to improve the edge and/or boundary features in phase contrast imaging. The experiments were conducted by employing a custom designed tissue simulating phantom, which also simulated a clinical condition where the ligand-targeted microbubbles are self-aggregated on the endothelium of blood vessels surrounding malignant cells. Four different concentrations of microbubble suspensions were injected into the phantom: 0%, 0.1%, 0.2%, and 0.4%. A time delay of 5 min was implemented before image acquisition to allow the microbubbles to become distributed at the interface between the acrylic and the cavity simulating a blood vessel segment. For comparison purposes, images were acquired using three system configurations for both projection and tomosynthesis imaging with a fixed radiation dose delivery: conventional low-energy contact mode, low-energy in-line phase contrast and high-energy in-line phase contrast. The resultant images illustrate the edge feature enhancements in the in-line phase contrast imaging mode when the microbubble concentration is extremely low. The quantitative edge-enhancement-to-noise ratio calculations not only agree with the direct image observations, but also indicate that the edge feature enhancement can be improved by increasing the microbubble concentration. In addition, high-energy in-line phase contrast imaging provided better performance in detecting low-concentration microbubble distributions.Keywords
Funding Information
- Oklahoma Tobacco Settlement Endowment Trust
- Charles and Jean Smith Chair endowment fund
- National Institutes of Health (R01 CA193378)
This publication has 34 references indexed in Scilit:
- Quantification of microbubble concentration through x-ray phase contrast imagingApplied Physics Letters, 2013
- Quantitative wave-optical numerical analysis of the dark-field signal in grating-based X-ray interferometryEurophysics Letters, 2012
- Microbubbles as contrast agent for in-line x-ray phase-contrast imagingApplied Physics Letters, 2011
- Microbubble-based synchrotron radiation phase contrast imaging: basic study and angiography applicationsPhysics in Medicine & Biology, 2011
- Molecular Imaging of Vascular Phenotype in Cardiovascular Disease: New Diagnostic Opportunities on the HorizonJournal of the American Society of Echocardiography, 2010
- Microbubbles as x-ray scattering contrast agents using analyzer-based imagingPhysics in Medicine & Biology, 2010
- Digital tomosynthesis with an on-board kilovoltage imaging deviceInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- Quantitative comparison between two phase contrast techniques: diffraction enhanced imaging and phase propagation imagingPhysics in Medicine & Biology, 2005
- An experimental method of determining relative phase‐contrast factor for x‐ray imaging systemsMedical Physics, 2004
- Practical cone-beam algorithmJournal of the Optical Society of America A, 1984