DWDi Wu

Di Wu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Di Wu has a total of 62 co-authors. Here are the top co-authors by number of shared publications:

  • Bin Zheng

    School of Electrical and Computer Engineering, University of Oklahoma, 110 West Boyd Street, Norman, OK 73019, United States of America

    2 shared publications
  • Cheng Peng

    Mass Laboratory, National Institute of Metrology, Beijing, China

    2 shared publications
  • Hong Liu

    Advanced Medical Imaging Center and School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK 73019, USA

    2 shared publications
  • Jian Wang

    Mass Laboratory, National Institute of Metrology, Beijing, China

    2 shared publications
  • Laurie Fajardo

    Department Radiology and Imaging Sciences, University of Utah, 50N Medical Dr Salt Lake City, UT 84132, United States of America

    2 shared publications
  • Molly Donovan Wong

    School of Electrical and Computer Engineering, University of Oklahoma, 110 West Boyd Street, Norman, OK 73019, United States of America

    2 shared publications

Latest Publications

  • Final report on the CCM key comparison of kilogram realizations CCM.M-K8.2021

    by M Stock, P Conceição, H Fang, F Bielsa, A Kiss, L Nielsen, F Beaudoux, P Espel, M Thomas, D Ziane, et al.

    Main text: This report describes the second CCM key comparison of realizations of the kilogram definition based on the fixed numerical value of the Planck constant, which came into force on 20 May 2019. The objectives were to determine the level of agreement between realizations of the kilogram using Kibble and joule balances and the x-ray crystal density (XRCD) method and to provide input for the calculation of the second "consensus value" of the kilogram. The consensus value serves as the basis for an internationally coordinated dissemination of the kilogram and is updated after each new key comparison. Its use will continue until satisfactory agreement between realization experiments has been achieved. Another objective was the determination of the reproducibility of the realization experiments by comparing the new results with those of the first key comparison of kilogram realizations, CCM.M-K8.2019. The comparison was organized by the BIPM and had nine participants. The BIPM, LNE, METAS, NIST, NRC and UME operated Kibble balances, the NIM used a joule balance and the NMIJ and the PTB participated using 28Si spheres, the masses of which were determined with the XRCD method. These realization methods were used to calibrate 1 kg mass standards under vacuum or in air. The standards were sent to the BIPM where they were compared with each other and with BIPM Pt-Ir working standards. The latter were calibrated traceable to the International Prototype of the Kilogram (IPK), the mass of which served as the definition of the kilogram until 20 May 2019. The results of the weighings at the BIPM together with the measurement results communicated by the participants allowed comparison of the values attributed to 1 kg mass standards using the realization experiments of the participants. The level of agreement between mass determinations with the realization experiments and the BIPM as-maintained mass unit, traceable to the Planck constant through the mass of the International Prototype of the Kilogram, could also be deduced. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).


  • Open Access

    Research on the Computer Controlled Velocity Simulation Device for Continuous Totalizing Automatic Weighing Instruments

    by Ruilin Zhong, Di Wu, Jian Wang, Hanghang Chen, Changqing Cai, Manhong Hu, Kai Jiao, Jing’aN Ding

    Continuous totalizing automatic weighing instruments is widely used in many industries, and need to be tested under different conditions especially for different temperature, humidity and electrical disturbance. Usually this kind of weighing instruments are very large and can not be put into such test environments, thus a test sample without belt conveyor is needed. Due to the working principle of continuous totalizing automatic weighing instruments, the test sample may include not only essential part of weighing instruments such as load cell, indicator, and load receptor, but also a device to simulate the displacement of the belt. In the paper, a device that can simulate the velocity of the belt is researched, it can generate square pulse signals to the test sample, thus the sample can operate as normal belt weigher. The configuration of the device is discussed and example is given to show its effectiveness.


  • Open Access

    Impacts of Air Density Fluctuations Toward the Mass Measurements of a 1 kg Silicon Sphere

    by Cheng Peng, Jian Wang, Di Wu

    After the revision of the International System of Units (SI) in May 2019, the Planck constant h became the top of the dissemination system for the kilogram. However, the Planck constant is difficult or impractical to use in daily calibrations. Thus, in many applications, alternative physical artefacts are used as mass standards for dissemination. Mass measurements of silicon spheres for the determination of Avogadro and Planck constants have shown that silicon spheres possess stability with high accuracy, thus can be utilized as mass standards. However, the material and the geometry properties of silicon spheres are different from classic mass standards commonly used for the dissemination of the kilogram. It is therefore necessary to determine mass corrections of silicon spheres to improve mass measurements. The effect of air density fluctuations in air buoyancy correction of silicon spheres mass measurements is investigated in this paper. Six types of air density fluctuations for three different weighing processes are summarized. In addition, a method to minimize the impact of air density fluctuation by applying real-time air density data to estimate the air buoyancy correction is proposed. Mass comparisons using a 1 kg silicon sphere and classic mass standards in various materials were conducted for method verification. Results show that the improved method using the real-time air density of each alternative weighing process can reduce the measurement errors by 8.7 μg to 39.0 μg in the air buoyancy correction, which is not negligible when performing high accuracy mass measurements for the dissemination of the redefined SI mass unit using silicon spheres.


  • Open Access

    Quantitative investigation of the edge enhancement in in-line phase contrast projections and tomosynthesis provided by distributing microbubbles on the interface between two tissues: a phantom study

    by Di Wu, Molly Donovan Wong, Yuhua Li, Laurie Fajardo, Bin Zheng, Xizeng Wu, Hong Liu

    The objective of this study was to quantitatively investigate the ability to distribute microbubbles along the interface between two tissues, in an effort to improve the edge and/or boundary features in phase contrast imaging. The experiments were conducted by employing a custom designed tissue simulating phantom, which also simulated a clinical condition where the ligand-targeted microbubbles are self-aggregated on the endothelium of blood vessels surrounding malignant cells. Four different concentrations of microbubble suspensions were injected into the phantom: 0%, 0.1%, 0.2%, and 0.4%. A time delay of 5 min was implemented before image acquisition to allow the microbubbles to become distributed at the interface between the acrylic and the cavity simulating a blood vessel segment. For comparison purposes, images were acquired using three system configurations for both projection and tomosynthesis imaging with a fixed radiation dose delivery: conventional low-energy contact mode, low-energy in-line phase contrast and high-energy in-line phase contrast. The resultant images illustrate the edge feature enhancements in the in-line phase contrast imaging mode when the microbubble concentration is extremely low. The quantitative edge-enhancement-to-noise ratio calculations not only agree with the direct image observations, but also indicate that the edge feature enhancement can be improved by increasing the microbubble concentration. In addition, high-energy in-line phase contrast imaging provided better performance in detecting low-concentration microbubble distributions.