Usability of a Patch-Type Ultrasound System for Non-Invasive Hemodynamic Monitoring: A Simulation Study in Anesthesiologists
Open Access
- 7 April 2026
- journal article
- research article
- Published by MDPI AG in Healthcare
- Vol. 14 (7) , 971
Abstract
Background/Objectives: Non-invasive hemodynamic monitoring technologies are being developed to support clinical decisions while reducing risks from invasive procedures. Usability evaluation is essential to assess safety and effectiveness before commercial release. This study examined the usability of a novel patch-type ultrasound-based system (CW10) designed for continuous monitoring in perioperative settings. Methods: A summative evaluation was conducted following IEC 62366-1 with 15 anesthesiologists. Potential hazards were identified via the FDA MAUDE database (Code: DQK) to inform test scenarios. Participants were stratified by clinical experience (1–p > 0.05). The mean SUS score was 78.5, corresponding to a “Good” usability level. While some use errors occurred in tasks like probe orientation, root cause analysis suggested these were likely due to negative transfer from prior device experience rather than interface complexity. Conclusions: The results suggest the system demonstrates acceptable usability and consistent operation across experience levels. Integrated automated features and the patch design may contribute to reducing inter-user variability for continuous monitoring. This study provides usability evidence that may inform the development of similar non-invasive technologies.Keywords
Funding Information
- Korea Medical Device Development Fund (RS-2023-00243901)
This publication has 32 references indexed in Scilit:
- Hemodynamic monitoring strategies in cardiac surgery: an update systematic reviewJournal of Clinical Monitoring and Computing, 2026
- Non-invasive Cardiac Output Monitoring in Congenital Heart DiseaseCurrent Treatment Options in Pediatrics, 2023
- New Developments in Continuous Hemodynamic Monitoring of the Critically Ill PatientCanadian Journal of Cardiology, 2023
- A novel, hands-free ultrasound patch for continuous monitoring of quantitative Doppler in the carotid arteryScientific Reports, 2021
- Continuous noninvasive pulse wave analysis using finger cuff technologies for arterial blood pressure and cardiac output monitoring in perioperative and intensive care medicine: a systematic review and meta-analysisBritish Journal of Anaesthesia, 2020
- New Developments in Hemodynamic MonitoringJournal of Cardiothoracic and Vascular Anesthesia, 2019
- Less invasive hemodynamic monitoring in critically ill patientsIntensive Care Medicine, 2016
- Guidelines for Performing a Comprehensive Transesophageal Echocardiographic Examination: Recommendations from the American Society of Echocardiography and the Society of Cardiovascular AnesthesiologistsJournal of the American Society of Echocardiography, 2013
- The validity of trans-esophageal Doppler ultrasonography as a measure of cardiac output in critically ill adultsIntensive Care Medicine, 2004
- Utility of esophageal Doppler as a minimally invasive hemodynamic monitor: a reviewCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2002