WJWonseuk Jang

Wonseuk Jang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Wonseuk Jang has a total of 76 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Perceived Barriers to Home-Based Telemedicine and Facilitators of Public Health Center-Based Telemedicine Among Digitally Capable Community-Dwelling Older Adults: A Cross-Sectional Scenario-Based Survey

    by Seung-Kwon Ji, Wonseuk Jang

    Background/Objectives: Home-based telemedicine requires patients to perform technical tasks independently, whereas assisted public health center (PHC)-based telemedicine transfers some of these tasks to on-site personnel. This study describes model-specific perceptions and estimates the difference in intention to use between the two scenarios among relatively digitally capable, community-dwelling older adults. Methods: A cross-sectional, fixed-order, scenario-based online survey was completed by 300 adults aged 65 years or older in South Korea. Home-based barriers and PHC-based facilitators were analyzed as non-equivalent descriptive domains. The primary paired comparison used three conceptually matched intention items. Internal consistency, exploratory factor evidence, 95% confidence intervals (CIs), Pearson and Spearman correlations, and multivariable linear regressions with HC3 robust standard errors were reported. Results: The seven-item home-based barrier score was 2.80 (SD 0.76; 95% CI 2.71–2.89), and the seven-item PHC facilitator score was 3.58 (SD 0.58; 95% CI 3.52–3.65). Intention scores were 3.91 (SD 0.64) for home-based and 3.88 (SD 0.66) for PHC-based telemedicine. The paired mean difference (PHC minus home) was −0.030 (95% CI −0.107 to 0.047; p = 0.441; Cohen’s dz = −0.045, bootstrap 95% CI −0.155 to 0.071). Preferences were home-based 42.7% (95% CI 37.2–48.3%), PHC-based 41.3% (95% CI 35.9–47.0%), and unsure 16.0% (95% CI 12.3–20.6%). After adjustment, digital literacy remained positively associated with both intention outcomes. Conclusions: No statistically detectable difference in intention to use was observed between the two hypothetical scenarios; this finding does not establish equivalence. The item-level results generate a hypothesis that staff-supported PHC delivery may be useful for some older adults, but actual uptake, effectiveness, accessibility, and equity require evaluation in real-world studies that include less digitally capable and more vulnerable populations.

  • Open Access

    Digital Literacy and Interpersonal Trust as Predictors of Willingness to Share Patient-Generated Health Data Among Korean Internet Users: Cross-Sectional Study Using Privacy Calculus and Communication Privacy Management Theories

    by Dongsu Lee, Wonseuk Jang

    Background: The proliferation of wearable devices and advances in data analytics are accelerating the adoption of personalized digital health care, relying heavily on patient-generated health data (PGHD). However, the sensitive nature of this data creates significant privacy boundaries. While previous research has focused on rational cost-benefit trade-offs, there is a limited understanding of how social and cognitive factors—specifically interpersonal trust and digital literacy (DL)—shape the data-sharing decisions of the general public. Objective: This study aims to identify the factors predicting individuals’ willingness to share health data (WS) by integrating privacy calculus and communication privacy management theories. It specifically examines the comparative influence of DL, interpersonal trust, and moral motivation on data-sharing decisions. Methods: We analyzed data from the 2023 Korea Panel Survey on the Digital Society (n=4518), a nationwide representative sample of internet users. Survey-weighted structural equation modeling with weighted least squares mean and variance adjusted estimation was used to examine the relationships among perceived risk (PR), perceived benefit (PB), DL, interpersonal trust, and WS. Results: PR was the strongest negative predictor of WS (standardized coefficient [std β ]=−0.189, P <.001), whereas PB was the strongest positive predictor (std β =0.076, P =.009), followed by moral motivation (std β =0.062, P =.03) and interpersonal trust. DL showed a significant negative direct association with willingness to share (std β = −0.060, P <.001). However, subdimension analysis revealed heterogeneous mechanisms: the “understanding” dimension was associated with lower PR and indirectly promoted sharing, whereas use and engagement were associated with higher PR. Age-stratified analyses suggested potential heterogeneity in these relationships, although the overall interaction was not statistically significant. Conclusions: PBs and risks were the strongest determinants of PGHD sharing, with benefits increasing and risks decreasing willingness to share. Beyond this risk-benefit balance, DL (particularly understanding) and interpersonal trust also played important roles, highlighting the need for trust-based and user-centric strategies to promote PGHD sharing and support the expansion of digital health care.


  • Open Access

    Usability of a Patch-Type Ultrasound System for Non-Invasive Hemodynamic Monitoring: A Simulation Study in Anesthesiologists

    by Soyeon Noh, Hyungmin Kim, Hyeonkyeong Choi, Wonseuk Jang

    Background/Objectives: Non-invasive hemodynamic monitoring technologies are being developed to support clinical decisions while reducing risks from invasive procedures. Usability evaluation is essential to assess safety and effectiveness before commercial release. This study examined the usability of a novel patch-type ultrasound-based system (CW10) designed for continuous monitoring in perioperative settings. Methods: A summative evaluation was conducted following IEC 62366-1 with 15 anesthesiologists. Potential hazards were identified via the FDA MAUDE database (Code: DQK) to inform test scenarios. Participants were stratified by clinical experience (1–p > 0.05). The mean SUS score was 78.5, corresponding to a “Good” usability level. While some use errors occurred in tasks like probe orientation, root cause analysis suggested these were likely due to negative transfer from prior device experience rather than interface complexity. Conclusions: The results suggest the system demonstrates acceptable usability and consistent operation across experience levels. Integrated automated features and the patch design may contribute to reducing inter-user variability for continuous monitoring. This study provides usability evidence that may inform the development of similar non-invasive technologies.

  • Open Access

    Effectiveness Assessment of a Multi-Functional Neonatal Incubator in the NICU

    by Hyeonkyeong Choi, Wonseuk Jang

    Background/Objectives: Preterm and critically ill neonates in neonatal intensive care units (NICUs) require multiple medical devices, including incubators, radiant warmers, phototherapy systems, and patient monitors. The coexistence of standalone devices without interoperability increases cognitive and operational burdens for healthcare providers and leads to spatial inefficiency. This study aimed to develop and evaluate a multi-functional neonatal incubator integrating these core functions into a single platform, using user-centered design (UCD) and usability engineering principles. Methods: By synthesizing and analyzing international standards (ISO 13485, IEC 62366-1, IEC 62366-2, and ISO 9241-210), a four-phase design process was established. Following the development of the monitoring system, the design was iteratively refined and validated through repeated formative usability evaluations. A summative usability evaluation was then conducted with 20 NICU clinicians in a simulated NICU environment, using 13 scenarios comprising 39 tasks. Outcome measures included task success rate, the After-Scenario Questionnaire (ASQ), the NASA Task Load Index (NASA-TLX), and the System Usability Scale (SUS). Results: The overall task success rate was 95.64%. When analyzed by function, success rates were 94.63% for incubator-related tasks, 98.33% for patient monitoring, 96.67% for radiant warmer tasks, and 98.33% for phototherapy tasks. The mean SUS score was 78.63, exceeding the benchmark score of 68 that indicates good usability. In addition, no statistically significant differences were observed in workload (NASA-TLX) or usability (SUS) scores according to clinical role or length of clinical experience. Conclusions: The multi-functional neonatal incubator developed in this study demonstrated high usability despite the integration of multiple medical device functions. The findings suggest that this integrated system has the potential to enhance clinical workflow efficiency, optimize spatial utilization, and improve patient safety in NICU settings.

  • Open Access

    Usability Validation of an Integrated Hemodynamic and Pulmonary Monitoring System Using Eye-Tracking Analysis

    by Hyunju Jeong, Hyeonkyeong Choi, Hyungmin Kim, Wonseuk Jang

    Background/Objectives: Hemodynamic monitoring is essential for guiding appropriate treatment by assessing cardiac output and volume status, as well as for preventing complications associated with excessive fluid administration. The EdgeFlow CW10 Plus is a device that extends conventional hemodynamic monitoring by incorporating pulmonary abnormality surveillance through B-line detection. This study aimed to evaluate whether the hemodynamic monitoring and pulmonary monitoring functions are well integrated, and verify the usability and efficiency of the system. Methods: A usability test was conducted with a panel of 15 medical professionals from diverse specialties and varying levels of clinical experience. Data from satisfaction surveys, heat maps, the System Usability Scale (SUS), and the NASA-TLX were analyzed to determine whether usability differences existed based on the duration of clinical experience. Results: The device demonstrated a high overall task success rate, averaging 93.2%. Regarding eye-tracking analysis based on clinical experience, it was observed that participants with more years of experience either failed to direct their gaze toward task-relevant user interface (UI) elements as effectively as those with fewer years of experience or showed similar patterns. Conclusions: The usability evaluation confirmed that the hemodynamic and pulmonary monitoring functions of the EdgeFlow CW 10 PLUS are well integrated, with the device demonstrating high usability and satisfaction. This integration is expected to support medical professionals in monitoring cardiac output and fluid status, facilitating timely therapeutic interventions while preventing complications related to fluid overload.

  • Open Access

    Usability Evaluation of a Central Monitoring System with AI-Based Cardiac Arrest Prediction in the ICU

    by Jiyoon Oh, Yourim Kim, Wonseuk Jang

    Background/Objectives: The incidence of cardiac arrest among critically ill patients has been increasing, with many patients experiencing clinical exacerbation prior to the event. Early detection and rapid treatment are essential to reduce the risks associated with cardiac arrest; however, difficulties such as limited ICU resources and inadequate monitoring of vital signs reduce the effectiveness of treatment. Various cardiac arrest prediction systems have been developed to overcome these issues. This study performed a summative evaluation of a Central Monitoring System with AI-based Cardiac Arrest Prediction. Methods: A summative usability evaluation was conducted in a simulated ICU environment with 22 ICU nurses experienced in using patient monitoring devices. Participants completed tasks based on the device workflow and then filled out the System Usability Scale (SUS) and satisfaction surveys, with task performance and survey responses analyzed to assess usability. Results: The usability test achieved a task success rate of 90%, with critical tasks achieving success rates ranging from 73% to 100%. The SUS score was 67.3 (“OK”), and the satisfaction survey showed an average score of 4.5, indicating generally positive user perception. Conclusions: Participants generally rated the system as acceptable, although some tasks showed lower success rates due to design issues such as poor button visibility. Further studies in clinical settings are needed to evaluate the system’s effectiveness, user experience, and contribution to the timely detection of cardiac arrest.

  • Open Access

    Reducing False Alarm Rates and Workload in ICUs by Improving Arrhythmia Detection Algorithms of Patient Monitoring Systems

    by Jiyoon Oh, You Rim Kim, Yong Ju Lee, Dae Keun Jeon, Ji Soo Choi, Jae-Sun Uhm, Chul-Min Ahn, Won Seuk Jang

    BACKGROUND Patient monitoring systems are widely used in intensive care units (ICUs) to monitor patient's conditions. A high false alarm rate can lead to alarm fatigue among nurses, increasing workload and stress. This study aimed to improve the accuracy of arrhythmia detection by enhancing the noise detection algorithm in patient monitoring systems and to determine whether false alarm rate and workload decreased through clinical trials. MATERIAL AND METHODS Trials were conducted on adult patients in the ICU at Yongin Severance Hospital who required continuous electrocardiogram (ECG) monitoring for at least 2 days. After the first trial, the noise detection algorithm of the M50 (investigational device) was improved, and a second trial was conducted to evaluate its performance. Both trials followed the same study design. During the study period, M50 and MX700 (comparator device) were applied simultaneously for 3 days. Arrhythmia alarms were reviewed by an independent evaluator who assessed false alarms by comparing them with the ECG signals. False alarm rates were compared between trials using the chi-square (χ²) test. RESULTS The clinical trial was conducted through 2 separate trials, with 17 and 11 participants, respectively. A comparative analysis of false alarm rates of the investigational device demonstrated a reduction from 71.75% to 27.61%. Statistical analysis using the chi-square test indicated a P value of 0.000 (<0.001), confirming a statistically significant difference. CONCLUSIONS The results of 2 trials demonstrated reductions in false alarm rate and NASA-TLX score. These findings suggest that enhancing the noise detection algorithm in the patient monitoring system improved arrhythmia detection accuracy and helped reduce nurses' workload.


  • Open Access

    Assessing the Usability of a Prescription-Based Mobile App for Patients With Panic Disorder and Its Management Console for Clinicians: Controlled User Study

    by Yujin Ko, Jeemin Lee, Kyunghee Ham, Yesol Cho, Yu-Bin Shin, Choongki Min, Kyungnam Kim, Wonseuk Jang, Hayeon Jung, Jae-Jin Kim

    Background: Panic disorder is characterized by sudden panic attacks and persistent anticipatory anxiety. While pharmacotherapy remains effective, patients with panic disorder often experience residual symptoms and functional impairments. Lifestyle factors influence symptom severity but are often unaddressed in routine psychiatric care. Most current digital therapeutics for panic disorder have a limited scope, lack integration with clinicians, and fail to consider behavioral patterns. To address these limitations, our research team developed a prescription-based app that supports structured cognitive behavioral therapy practice, real-life symptom management, and lifestyle modifications for patients with panic disorder, and a management console—a web-based platform that allows clinicians to monitor the patients’ engagement and progress as well as determine therapeutic options if necessary. Objective: This study aimed to test the usability of the app and management console by evaluating their interface, functionality, and user experience. The primary goal was to identify the strengths and areas for further improvement of these software devices and to develop a list of modifications to improve the user experience and clinical applicability in updates to refine the devices for a future clinical trial. Methods: Usability data were collected by investigators at a medical device usability research center without the involvement of the development research team, and the participants were 15 patients with panic disorder and 15 psychiatrists. Each group completed experimental use of the app or management console and scored the convenience and safety of its modules, questionnaire evaluations for the acceptability, and presentation of verbal subjective feedback on areas for improvement. Based on the participants’ suggestions, a list of items that need to be modified to improve functionality and ease of use for each device was created. Results: Patients completed 155 assigned tasks for the app with more than 98% success, and psychiatrists completed 34 tasks for the management console with more than 86% success. The convenience and safety scores for the app and management console exceeded the neutral threshold (mean >4.5). For all statements about the acceptability, both patients and psychiatrists responded at the level of agreeing with a score exceeding 3 (mean: 3.6~4.3 and 4~4.7, respectively). There were 38 suggestions for app improvements and 66 suggestions for management console improvements, most of which were incorporated in the modification list. Conclusions: Patients reported that the app might be easy to use and help manage anxiety, and psychiatrists found the management console practical and well-suited for outpatients. By combining patient-facing therapeutic tools with clinician-driven prescription and monitoring, the devices offer a solution aligned with clinically integrated, real-world psychiatric care. Modified devices based on the improvement suggestions presented in this study will be evaluated in future clinical trials for their impact on engagement and treatment outcomes.


  • Open Access

    Enhancing the Usability of Patient Monitoring Devices in Intensive Care Units: Usability Engineering Processes for Early Warning System (EWS) Evaluation and Design

    by Hyeonkyeong Choi, Yourim Kim, Wonseuk Jang

    Background/Objectives: This study aimed to enhance the usability of patient monitoring systems by integrating the Early Warning Score (EWS) function and improving user interface elements. The EWS function is expected to enable the early detection of acute deterioration and prompt medical intervention, while the optimized design supports rapid decision-making by nursing staff. Methods: Two formative usability evaluations were conducted to identify user requirements and improve the device design. A simulated usability test involved five ICU medical staff members, followed by a user preference survey with 72 ICU staff members in a real clinical setting. After incorporating feedback, a summative usability test with 23 ICU nurses was performed to evaluate the revised device. Results: Issues related to unfamiliar parameter terminology and alarm message positioning were identified, and the need for the EWS function was emphasized. The summative evaluation showed an increase in task success rate from 86% to 90% and a significant improvement in user satisfaction from 74.85 (SD: 0.88) to 89.55 (SD: 0.75) (p < 0.05). Conclusions: The integration of the EWS function and interface improvements significantly enhanced the usability of patient monitoring system. These advancements are expected to enable rapid detection of patient deterioration and support timely clinical decision-making by ICU staff.