Robotic-arm assistance in revision total hip arthroplasty improves the accuracy of acetabular component positioning: a cadaver-based study
Open Access
- 18 July 2026
- journal article
- research article
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 146 (1) , 262
Abstract
Introduction Acetabular component positioning is a key factor for stability, impingement, wear, and biomechanics in revision total hip arthroplasty (THA). However, anatomic distortion and previous implants may complicate positioning. Although evidence on computed-tomography (CT)-based robotic assistance in revision THA is limited, its planning features and precision may improve surgical plan execution. This study aimed to measure the precision and accuracy of acetabular component positioning of revision robotic-arm assisted total hip arthroplasty (RA-THA) compared with a published manual primary total hip arthroplasty (M-THA) benchmark for: (a) acetabular inclination; (b) acetabular version; and (c) center of rotation (COR), with comparison by surgeon case volume. Materials and methods There were seven cadavers (nine hips) that previously underwent primary THA revised with RA-THA by independent surgeons with varying primary RA-THA case volumes, surgical approaches, and acetabular component types. Due to surgical protocol deviations, two hips were excluded leaving seven hips from six cadavers. Pre- and postoperative CT scans were compared to calculate absolute error for inclination, version, and COR; normality was established with the Anderson-Darling test and two-variance tests assessed differences in standard deviations (α = 0.05). Mean differences between cadaver-based revision RA-THA and published M-THA values were compared with Welch's t-test for superiority (α = 0.05). Effect sizes were reported as mean differences with 95% upper bounds and sensitivity analyses were performed given the fixed sample size. Results Revision RA-THA demonstrated significantly greater accuracy for acetabular inclination (2.5 ± 1.9° versus 7.2 ± 3.2°, P = 0.008) and version (2.2 ± 1.6° versus 7.8 ± 4.6°, P = 0.014), and significantly greater precision for acetabular version (P = 0.023) compared with M-THA. There was adirectionally lower error for COR compared with M-THA. Mean error reductions were 5.7° for version and 4.7º for inclination with 95% upper bounds of -1.9 for both version and inclination. Low RA-THA surgical volume corresponded with the highest absolute error for shell inclination (5.5º) and version (5.0º), though values remained below published M-THA averages. Conclusions Revision RA-THA reduced error in both acetabular inclination and acetabular version, and variability in acetabular version relative to the M-THA benchmark. Although these results relate only to technical performance, accurate acetabular positioning in clinical practice is an important factor in reducing the risk of malposition-related complications in revision THA.Keywords
Funding Information
- Stryker
This publication has 34 references indexed in Scilit:
- Robotic Assistance is Associated With No Intraoperative Fluoroscopy or Radiation Exposure During Direct Anterior Total Hip ArthroplastyArthroplasty Today, 2025
- Mobility of the lumbo-pelvic-hip complex (spinopelvic mobility) and sagittal spinal alignment - implications for surgeons performing hip arthroplastyArchives of orthopaedic and trauma surgery, 2024
- Current and potential use of fresh frozen cadaver in surgical training and anatomical educationAnatomical Sciences Education, 2021
- Robots in the Operating Room During Hip and Knee ArthroplastyCurrent Reviews in Musculoskeletal Medicine, 2020
- Prevention of Dislocation After Total Hip ArthroplastyThe Journal of Arthroplasty, 2018
- The Impact of Spino-Pelvic Alignment on Total Hip Arthroplasty Outcomes: A Critical Analysis of Current EvidenceThe Journal of Arthroplasty, 2018
- Acetabular Component Position and the Risk of Dislocation Following Primary and Revision Total Hip Arthroplasty: A Matched Cohort AnalysisThe Journal of Arthroplasty, 2017
- Redefining the Acetabular Component Safe Zone for Posterior Approach Total Hip ArthroplastyThe Journal of Arthroplasty, 2016
- The effect of acetabular and femoral component version on dislocation in primary total hip arthroplastyInternational Orthopaedics, 2015
- What Safe Zone? The Vast Majority of Dislocated THAs Are Within the Lewinnek Safe Zone for Acetabular Component PositionClinical Orthopaedics and Related Research, 2015