CSChase W. Smitterberg

Chase W. Smitterberg

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Chase W. Smitterberg has a total of 63 co-authors. Here are the top co-authors by number of shared publications:

  • Michael A. Mont

    The Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Maryland, United States

    18 shared publications
  • Ronald Emilio Delanois

    Department of Orthopaedic Surgery, Greater Baltimore Medical Center Inc, Towson, Maryland, United States

    8 shared publications
  • Giles R. Scuderi

    Northwell Health, Lenox Hill Hospital, United States

    5 shared publications
  • Amir H. Hoveidaei

    Department of Orthopaedic Surgery, LifeBridge Health Rubin Institute for Advanced Orthopedics, Baltimore, Maryland, United States

    4 shared publications
  • Amir Human Hoveidaei

    International Center for Limb Lengthening, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Schoeneman Building, 2nd Floor, 2401 West Belvedere Avenue, Baltimore, MD 21215, USA

    4 shared publications
  • James Nace

    Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, LifeBridge Health, Baltimore, Maryland, United States

    4 shared publications

Latest Publications

  • Open Access

    Correction: Robotic-arm assistance in revision total hip arthroplasty improves the accuracy of acetabular component positioning: a cadaver-based study

    by Kailey Fitzgerald, Ilya Borukhov, Varun Chandra, Chase Smitterberg, Michael A. Mont, Sally LiArno

  • Objective Quantification of Soft-Tissue Balance in Total Knee Arthroplasty: Expanded Validation of the Pendulum Knee Drop Test Across Multiple Surgeons

    by Kevin Abbruzzese, Michael A. Mont, Michael Dunbar, Jared Weir, Chase W. Smitterberg, Sally LiArno

    Despite increasing evidence showing major diversity in subjective balancing approaches, soft-tissue balance during total knee arthroplasty (TKA) remains primarily based upon empirical surgeon assessment. A quantitative technique for describing knee stiffness and laxity after TKA was previously introduced: the modified pendulum knee drop (PKD) test. This study expands upon prior validation work by evaluating the reproducibility of surgeon-directed balancing assessments compared with the modified PKD test across a larger cohort of arthroplasty surgeons. Robotic-assisted TKAs were performed on an advanced knee simulator model previously validated for ligament balancing investigations. After completing blinded polyethylene insert identification trials using manual balance assessments, eight high-volume arthroplasty surgeons underwent additional testing with the modified PKD test. During several testing cycles, polyethylene inserts ranging from 9 to 14 mm were randomly assigned and assessed. For both manual and PKD-assisted evaluations, accuracy, delta error, and intra- and interobserver reliability were computed. Stiffness and laxity behavior were described using oscillatory excursion measurements and logarithmic decrement values. Surgeons correctly identified polyethylene insert thickness manually in 60% of trials and within 1 mm in 84.2% of trials. In contrast, PKD-assisted balancing resulted in 97% correct insert identification (p < 0.001). The mean delta between surgeon-estimated and actual polyethylene thickness was 0.68 mm during manual assessment versus 0.05 mm with the PKD test (p < 0.001). Intraobserver reliability improved from a kappa of 0.61 during manual balancing to 0.96 with PKD assessment, while interobserver reliability improved from 0.38 to 0.97, respectively. The PKD test maintained highly reproducible thickness-independent stiffness ranking patterns across nearly all trials. High-volume arthroplasty surgeons demonstrated substantial variability during subjective soft-tissue balancing assessments, whereas the modified PKD test provided highly reproducible, objective biomechanical characterization of stiffness and laxity during TKA. These expanded findings further validate the PKD methodology as a reproducible tool to quantify soft-tissue knee laxity during robotic-assisted TKA.

  • Pulsed Electrical Stimulation for Knee Osteoarthritis: Reappraisal of a 21-Year Clinical Development Program

    by Michael A. Mont, Chase W. Smitterberg, Javad Parvizi, Thomas Zizic

    Knee osteoarthritis (OA) remains a leading cause of pain and disability, yet few nonoperative therapies have demonstrated durable clinical benefit or potential effects on structural disease progression. Pulsed electrical stimulation (PES) was investigated extensively over two decades, but this evidence has received little attention in the contemporary era of disease-modifying OA research. A structured evidence synthesis was performed of five principal prospective clinical investigations evaluating capacitively coupled PES for symptomatic knee OA. These included two randomized double-blind placebo-controlled trials, one multicenter phase IV investigation, one long-term observational study of arthroplasty deferral, and one histologic and radiographic study assessing structural cartilage changes. Collectively, the studies included 587 patients treated over more than 20 years. Clinical outcomes, functional improvement, medication utilization, safety, arthroplasty deferral, and structural findings were systematically reviewed and synthesized. Across investigations, PES consistently improved pain, physical function, physician and patient global assessments, and overall clinical status. Randomized controlled trials demonstrated significant improvements compared with placebo, while the multicenter phase IV study confirmed effectiveness in routine practice and identified a dose–response relationship, with superior outcomes following greater cumulative treatment exposure. Approximately 45% of patients reduced nonsteroidal anti-inflammatory drug use by at least 50%, and nearly 60% of compliant patients previously advised to undergo total knee arthroplasty deferred surgery for 4 years or longer. Tissue characterization in one patient, supported by radiographic observations in five additional patients, suggested hyaline-like cartilage formation and increased compartmental joint-space width. There were no serious device-related adverse events reported. More than two decades of prospective evidence suggest that PES improves pain, function, patient-reported outcomes, and clinical status while maintaining an excellent safety profile. These findings support a contemporary reappraisal of this technology as a nonoperative joint-preservation strategy for symptomatic knee OA.

  • Nontraumatic Osteonecrosis of the Femoral Head

    by Michael A. Mont, Chase W. Smitterberg, Lynne C. Jones, Stuart B. Goodman, Jay R. Lieberman, Javad Parvizi, Edward Y. Cheng

    ➢ Nontraumatic osteonecrosis of the femoral head should be suspected in patients who are <50 years of age who have persistent hip pain despite normal radiographs. ➢ Bilateral involvement is common; magnetic resonance imaging (MRI) of the contralateral hip is recommended. ➢ MRI is the most sensitive modality for detecting early disease. ➢ Femoral head sphericity is assessed on anteroposterior, lateral, and 30º view radiographs. ➢ Small pre-collapse lesions have the best prognosis. Large lateral lesions and subchondral collapse predict rapid progression. ➢ Systemic risk factors and multifocal disease should be actively evaluated. ➢ Joint-preserving procedures are most effective before structural collapse. ➢ Total hip arthroplasty remains the most reliable treatment after femoral head collapse.

  • Open Access

    Robotic-arm assistance in revision total hip arthroplasty improves the accuracy of acetabular component positioning: a cadaver-based study

    by Kailey Fitzgerald, Ilya Borukhov, Varun Chandra, Chase Smitterberg, Michael A. Mont, Sally LiArno

    Introduction Acetabular component positioning is a key factor for stability, impingement, wear, and biomechanics in revision total hip arthroplasty (THA). However, anatomic distortion and previous implants may complicate positioning. Although evidence on computed-tomography (CT)-based robotic assistance in revision THA is limited, its planning features and precision may improve surgical plan execution. This study aimed to measure the precision and accuracy of acetabular component positioning of revision robotic-arm assisted total hip arthroplasty (RA-THA) compared with a published manual primary total hip arthroplasty (M-THA) benchmark for: (a) acetabular inclination; (b) acetabular version; and (c) center of rotation (COR), with comparison by surgeon case volume. Materials and methods There were seven cadavers (nine hips) that previously underwent primary THA revised with RA-THA by independent surgeons with varying primary RA-THA case volumes, surgical approaches, and acetabular component types. Due to surgical protocol deviations, two hips were excluded leaving seven hips from six cadavers. Pre- and postoperative CT scans were compared to calculate absolute error for inclination, version, and COR; normality was established with the Anderson-Darling test and two-variance tests assessed differences in standard deviations (α = 0.05). Mean differences between cadaver-based revision RA-THA and published M-THA values were compared with Welch's t-test for superiority (α = 0.05). Effect sizes were reported as mean differences with 95% upper bounds and sensitivity analyses were performed given the fixed sample size. Results Revision RA-THA demonstrated significantly greater accuracy for acetabular inclination (2.5 ± 1.9° versus 7.2 ± 3.2°, P = 0.008) and version (2.2 ± 1.6° versus 7.8 ± 4.6°, P = 0.014), and significantly greater precision for acetabular version (P = 0.023) compared with M-THA. There was adirectionally lower error for COR compared with M-THA. Mean error reductions were 5.7° for version and 4.7º for inclination with 95% upper bounds of -1.9 for both version and inclination. Low RA-THA surgical volume corresponded with the highest absolute error for shell inclination (5.5º) and version (5.0º), though values remained below published M-THA averages. Conclusions Revision RA-THA reduced error in both acetabular inclination and acetabular version, and variability in acetabular version relative to the M-THA benchmark. Although these results relate only to technical performance, accurate acetabular positioning in clinical practice is an important factor in reducing the risk of malposition-related complications in revision THA.

  • Contemporary Management of Knee Chondral Defects

    by Chase W. Smitterberg, Giles R. Scuderi, Michael A. Mont

  • Contemporary Management of Knee Chondral Defects, Part II: Structural Cartilage Restoration with Focal Resurfacing Implants and Osteochondral Autograft Transfer

    by Chase W. Smitterberg, Giles R. Scuderi, Michael A. Mont

    Structural cartilage restoration strategies provide mechanical solutions for focal knee chondral defects in which biologic repair alone is unlikely to withstand load-bearing demands. These approaches are most applicable to discrete lesions in otherwise preserved joints where restoration of articular congruity and immediate mechanical stability are required. This review evaluates focal resurfacing implants and osteochondral autograft transfer system procedures as structural joint-preserving interventions. Contemporary metal and polymer-based focal implants demonstrate meaningful short- to mid-term improvements in pain and function. However, registry data and meta-analyses reveal variable survivorship and revision risk, frequently related to progressive osteoarthritis or implant-related complications. Outcomes are highly dependent on appropriate patient selection and precise implant positioning. Osteochondral autograft transfer system procedures and mosaicplasty restore mature hyaline cartilage and subchondral bone using autologous osteochondral plugs. Long-term series extending beyond a decade support durable outcomes in small, contained lesions. Donor-site morbidity, graft contouring limitations, and size constraints, however, restrict broader applicability. Comparative data highlight trade-offs between mechanical resurfacing and cartilage transfer. Implants avoid donor harvest, but introduce device survivorship concerns and complex revision pathways. Autograft transfer offers established durability with native tissue, but carries technical constraints and harvest-related morbidity. Structural restoration strategies occupy a defined position within the cartilage preservation continuum. Their success depends on alignment between defect characteristics, patient activity demands, and the surrounding joint environment. When applied within appropriate indications, these techniques can provide durable symptom relief, though none of them eliminates the risk of progression to arthroplasty.

  • Contemporary Management of Knee Chondral Defects, Part I: A Framework for Treatment Selection

    by Chase W. Smitterberg, Giles R. Scuderi, Michael A. Mont

    Focal chondral defects of the knee present a heterogeneous clinical problem with no universally applicable solution. Lesion size, containment, subchondral bone involvement, joint alignment, meniscal integrity, patient activity demands, and system-level constraints variably influence durability, yet outcomes are often interpreted without adequate contextualization. As a result, treatment comparisons frequently reflect differences in indication rather than superiority of technique. This review proposes a constraint-based framework to guide treatment selection in focal knee chondral defects. Cartilage restoration is conceptualized as a continuum of joint-preserving strategies, each occupying a defined role determined by mechanical demands, biologic plausibility, and practical feasibility. Available interventions are organized into five categories: structural resurfacing and transfer techniques, cell-based repair, marrow stimulation-based repair, scaffold-augmented repair, and osteochondral allograft transplantation. A structured decision algorithm is presented emphasizing sequential evaluation of the joint environment, defect characteristics, and patient-specific modifiers. The framework emphasizes that malalignment, instability, meniscal deficiency, and subchondral bone pathology must be addressed to optimize durability, and that lesion geometry and depth narrow the range of biologically and mechanically plausible options. Patient expectations and system constraints refine, but do not override, lesion-driven decision-making. Rather than positioning techniques hierarchically, this model highlights appropriate application boundaries and expected trade-offs. Durable symptom relief and delay of arthroplasty remain shared endpoints across modalities. By shifting emphasis from modality comparison to constraint matching, this framework provides a unified structure for interpreting the cartilage restoration literature and establishes the foundation for the modality-specific analyses presented in subsequent parts of this series.

  • Management Strategies for Tibial Periprosthetic Fractures After Total Knee Arthroplasty

    by Chase W. Smitterberg, Amir H. Hoveidaei, Ronald E. Delanois, Michael A. Mont

    Tibial periprosthetic fractures following total knee arthroplasty are relatively uncommon, but represent a complex and increasingly encountered complication given the growing volume of primary and revision arthroplasty procedures. These injuries present unique challenges due to compromised bone stock, implant-related constraints, and patient-specific factors such as advanced age and osteoporosis. The location of the fracture, implant stability, bone quality, and the functional needs of the patient all influence management tactics. While operative intervention is frequently necessary for displaced fractures or those linked to component loosening, nonoperative treatment may be suitable in certain individuals who have stable implants and slightly displaced fractures. Proximal tibial replacement in extreme situations, revision arthroplasty using stemmed components, and open reduction and internal fixation are surgical possibilities. This review summarizes current classification systems, treatment strategies, and outcomes, with an emphasis on practical decision-making. A treatment strategy centered first on implant stability and then on fracture pattern, bone stock, and patient factors provides the most useful framework for clinical decision-making.

  • Intraoperative Tibial Periprosthetic Fractures During Total Knee Arthroplasty: Incidence, Risk Factors, and Early Outcomes

    by Chase W. Smitterberg, Amir H. Hoveidaei, Ronald E. Delanois, Michael A. Mont

    Intraoperative tibial periprosthetic fractures during total knee arthroplasty (TKA) are uncommon, but clinically relevant complications with distinct mechanisms compared with postoperative fractures. This review summarizes the incidence, intraoperative risk factors and mechanisms, recognition, and early outcomes to provide a practical, procedure-based framework. In primary TKA, intraoperative tibial fractures occur in approximately 0.1 to 0.5% of cases, with higher rates reported in keeled tibial components and revision procedures, where incidence may approach 1.5%. These fractures occur at predictable high-force steps, most commonly during keel preparation and final component impaction, with 90 to 100% occurring at these stages across multiple series. The medial tibial plateau is particularly susceptible, and excessive insertion forces, implant size and geometry, and depth of tibial resection contribute to fracture risk. Recognition relies on intraoperative awareness of timing, tactile feedback, and subtle visual and mechanical cues. Audible cracking, sudden loss of resistance, abnormal component seating, and unexpected instability should prompt suspicion. Some fractures remain occult and are identified only on postoperative imaging, emphasizing the importance of vigilance during high-risk steps. Early outcomes are generally favorable when fractures are recognized and addressed at the time of surgery, with high rates of union and implant survivorship. Large series report survivorship free from tibial component revision exceeding 95% at up to a mean 6-year follow-up, although outcomes vary by fracture pattern. Intraoperative tibial periprosthetic fractures are predictable, mechanically driven complications that occur during specific steps of TKA. Understanding their timing, mechanisms, and presentation is essential to improve recognition and optimize outcomes.