A comparison of non-magnetic and magnetic beads for measuring IgG antibodies against P. vivax antigens in a multiplexed bead-based assay using Luminex ® technology (Bio-Plex ® 200 or MAGPIX ® )
Authors:
- Ramin MazhariRMRamin Mazhari
- Jessica BrewsterJBJessica Brewster
- Caitlin BourkeCBCaitlin Bourke
- Zoe Sj LiuZLZoe Sj Liu
- Eizo TakashimaETEizo Takashima
- Takafumi TsuboiTTTakafumi Tsuboi
- Wai-Hong ThamWTWai-Hong Tham
- Matthias HarbersMHMatthias Harbers
- Chetan ChitnisCCChetan Chitnis
- Julie HealerJHJulie Healer
- Maria Ome-KaiusMOMaria Ome-Kaius
Preprint
Abstract
Multiplexed bead-based assays that use Luminex xMAP ® technology have become popular for measuring antibodies against proteins of interest in many fields, including malaria and more recently SARS-CoV-2/COVID-19. There are currently two formats that are widely used: non-magnetic beads or magnetic beads. Data is lacking regarding the comparability of results obtained using these two types of beads, and for assays run on different instruments. Whilst non-magnetic beads can only be run on flow-based instruments (such as the Luminex ® 100/200™ or Bio-Plex ® 200), magnetic beads can be run on both these and the newer MAGPIX ® instruments. In this study we utilized a panel of purified recombinant Plasmodium vivax proteins and samples from malaria-endemic areas to measure P. vivax -specific IgG responses using different combinations of beads and instruments. We directly compared: i) non-magnetic versus magnetic beads run on a Bio-Plex ® 200, ii) magnetic beads run on the Bio-Plex ® 200 versus MAGPIX ® and iii) non-magnetic beads run on a Bio-Plex ® 200 versus magnetic beads run on the MAGPIX ® . We also performed an external validation of our optimized assay. We observed that IgG antibody responses, measured against our panel of P. vivax proteins, were strongly correlated in all three of our comparisons, however higher amounts of protein were required for coupling to magnetic beads. Our external validation indicated that results generated in different laboratories using the same coupled beads are also highly comparable, particularly if a reference standard curve is used.Keywords
All Related Versions
- Published version: PLOS ONE, 15 (12), e0238010.
This publication has 19 references indexed in Scilit:
- Highly sensitive and specific multiplex antibody assays to quantify immunoglobulins M, A and G against SARS-CoV-2 antigensbioRxiv, 2020
- Distinct systems serology features in children, elderly and COVID patientsmedRxiv, 2020
- Development and validation of serological markers for detecting recent Plasmodium vivax infectionNature Medicine, 2020
- Serological signatures of SARS-CoV-2 infection: Implications for antibody-based diagnosticsmedRxiv, 2020
- Optimization of a magnetic bead-based assay (MAGPIX®-Luminex) for immune surveillance of exposure to malaria using multiple Plasmodium antigens and sera from different endemic settingsMalaria Journal, 2018
- Analysis of factors affecting the variability of a quantitative suspension bead array assay measuring IgG to multiple Plasmodium antigensPLOS ONE, 2018
- Optimization of incubation conditions of Plasmodium falciparum antibody multiplex assays to measure IgG, IgG1–4, IgM and IgE using standard and customized reference pools for sero-epidemiological and vaccine studiesMalaria Journal, 2018
- Asymptomatic Plasmodium vivax infections induce robust IgG responses to multiple blood-stage proteins in a low-transmission region of western ThailandMalaria Journal, 2017
- Multiplexed Microsphere Suspension Array-Based Immunoassays2015
- The Relationship between Anti-merozoite Antibodies and Incidence of Plasmodium falciparum Malaria: A Systematic Review and Meta-analysisPLOS Medicine, 2010