MHMatthias Harbers

Matthias Harbers

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Matthias Harbers has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Easy Synthesis of Complex Biomolecular Assemblies: Wheat Germ Cell-Free Protein Expression in Structural Biology

    by Marie-Laure Fogeron, Lauriane Lecoq, Laura Cole, Matthias Harbers, Anja Böckmann

    Cell-free protein synthesis (CFPS) systems are gaining more importance as universal tools for basic research, applied sciences, and product development with new technologies emerging for their application. Huge progress was made in the field of synthetic biology using CFPS to develop new proteins for technical applications and therapy. Out of the available CFPS systems, wheat germ cell-free protein synthesis (WG-CFPS) merges the highest yields with the use of a eukaryotic ribosome, making it an excellent approach for the synthesis of complex eukaryotic proteins including, for example, protein complexes and membrane proteins. Separating the translation reaction from other cellular processes, CFPS offers a flexible means to adapt translation reactions to protein needs. There is a large demand for such potent, easy-to-use, rapid protein expression systems, which are optimally serving protein requirements to drive biochemical and structural biology research. We summarize here a general workflow for a wheat germ system providing examples from the literature, as well as applications used for our own studies in structural biology. With this review, we want to highlight the tremendous potential of the rapidly evolving and highly versatile CFPS systems, making them more widely used as common tools to recombinantly prepare particularly challenging recombinant eukaryotic proteins.


  • Open Access

    A comparison of non-magnetic and magnetic beads for measuring IgG antibodies against P. vivax antigens in a multiplexed bead-based assay using Luminex ® technology (Bio-Plex ® 200 or MAGPIX ® )

    by Ramin Mazhari, Jessica Brewster, Rich Fong, Caitlin Bourke, Zoe Sj Liu, Eizo Takashima, Takafumi Tsuboi, Wai-Hong Tham, Matthias Harbers, Chetan Chitnis, et al.

    Multiplexed bead-based assays that use Luminex xMAP ® technology have become popular for measuring antibodies against proteins of interest in many fields, including malaria and more recently SARS-CoV-2/COVID-19. There are currently two formats that are widely used: non-magnetic beads or magnetic beads. Data is lacking regarding the comparability of results obtained using these two types of beads, and for assays run on different instruments. Whilst non-magnetic beads can only be run on flow-based instruments (such as the Luminex ® 100/200™ or Bio-Plex ® 200), magnetic beads can be run on both these and the newer MAGPIX ® instruments. In this study we utilized a panel of purified recombinant Plasmodium vivax proteins and samples from malaria-endemic areas to measure P. vivax -specific IgG responses using different combinations of beads and instruments. We directly compared: i) non-magnetic versus magnetic beads run on a Bio-Plex ® 200, ii) magnetic beads run on the Bio-Plex ® 200 versus MAGPIX ® and iii) non-magnetic beads run on a Bio-Plex ® 200 versus magnetic beads run on the MAGPIX ® . We also performed an external validation of our optimized assay. We observed that IgG antibody responses, measured against our panel of P. vivax proteins, were strongly correlated in all three of our comparisons, however higher amounts of protein were required for coupling to magnetic beads. Our external validation indicated that results generated in different laboratories using the same coupled beads are also highly comparable, particularly if a reference standard curve is used.


  • Open Access

    IgG antibody responses are preferential compared to IgM for use as serological markers for detecting recent exposure to Plasmodium vivax infection

    by Rhea J Longley, Michael T White, Jessica Brewster, Zoe Sj Liu, Caitlin Bourke, Eizo Takashima, Matthias Harbers, Wai-Hong Tham, Julie Healer, Chetan E Chitnis, et al.

    To achieve malaria elimination, new tools are required to explicitly target Plasmodium vivax . Recently, a novel panel of P. vivax proteins were identified and validated as serological markers for detecting recent exposure to P. vivax within the last 9 months. In order to improve the sensitivity and specificity of these markers, IgM in addition to IgG antibody responses were assessed to a down-selected panel of 20 P. vivax proteins. IgM was tested using archival plasma samples from observational cohort studies conducted in malaria-endemic regions of Thailand and Brazil. IgM responses to these proteins generally had poorer classification performance than IgG.

  • Open Access

    Development and validation of serological markers for detecting recent exposure to Plasmodium vivax infection

    by Rhea Jessica Longley, Michael T. White, Eizo Takashima, Jessica Brewster, Masayuki Morita, Matthias Harbers, Leanne J. Robinson, Fumie Matsuura, Shih-Jung (Zoe) Liu, Connie S. N. Li-Wai-Suen, et al.

    In order to accelerate towards malaria elimination, improved targeting of limited resources is essential. A major gap in our elimination toolkit for Plasmodium vivax malaria is the identification of individuals carrying arrested liver stages, called hypnozoites. These clinically silent but frequently relapsing hypnozoites are key to P. vivax persistence. Whilst hypnozoites cannot be directly detected, individuals who have had recent exposure to P. vivax and have not been treated are likely to harbor these parasites. By measuring IgG antibody responses to over 300 P. vivax proteins, a panel of serological markers capable of detecting exposure to P. vivax infections in the prior 9-month period was identified and validated. Using antibody responses to 8 P. vivax proteins, 80% sensitivity and specificity for detecting recent infections were achieved in three independent studies conducted in Thailand, Brazil and the Solomon Islands. As these individuals have a high likelihood of harboring hypnozoites, the suite of these 8 antibody responses can serve as biomarkers for the identification of individuals who should be targeted for treatment with liver-stage drugs such as primaquine and tafenoquine in mass drug administration programs aimed at controlling and eliminating P. vivax malaria. One Sentence Summary: The manuscript describes identification and validation of a novel panel of P. vivax proteins that can be used to detect recent exposure to P. vivax infections within the prior 9 months.