Effect of Nitrification and GAC Filtration on Copper and Lead Leaching in Home Plumbing Systems
- 1 July 2008
- journal article
- research article
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 134 (7) , 521-530
Abstract
Nitrification and granular activated carbon (GAC) filtration impact leaching of lead/copper to potable water under typical home plumbing configurations. GAC filters removed the disinfectant and caused rapid establishment of nitrification in chloraminated systems. The potential adverse consequences of whole house GAC filters deserve increased scrutiny in chloraminated systems. The lower pH values from nitrification and other microbes during overnight stagnation in pipes can markedly increase (up to 800%) lead and copper contamination of water.Keywords
This publication has 30 references indexed in Scilit:
- Unintended Consequences of Chloramine Hit HomeProceedings of the Water Environment Federation, 2005
- role of chlorine and chloramine in corrosion of lead‐bearing plumbing materialsJournal AWWA, 2004
- Effect of chlorine on corrosion in Drinking Water SystemsJournal AWWA, 2003
- Biocorrosion of Copper in Potable WaterJournal AWWA, 2001
- Role of temperature, chlorine, and organic matter in copper corrosion by-product release in soft waterWater Research, 2001
- Organic matter and copper corrosion by-product release: a mechanistic studyCorrosion Science, 2001
- The blue water phenomenonJournal AWWA, 2000
- Effects ofarthrobactersp.,acidovorax delafieldii, andbacillus megateriumcolonisation on copper solvency in a laboratory reactorBiofouling, 1996
- Accelerated Testing of Copper CorrosionJournal AWWA, 1993
- The corrosion of copper by chlorinated drinking watersWater Research, 1982