Evaluation of corneal endothelium damage with a new handheld fragmentation device
- 1 July 2025
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (7) , 612-617
Abstract
Purpose: To quantify damage to corneal endothelial cells (CECs) from a new handheld lens fragmentation device and compare it with damage from a standard phacoemulsification device. Setting: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah. Design: Experimental study. Methods: 15 New Zealand white rabbits received bilateral surgery. Their eyes were divided into 3 groups (10 eyes/group): Intrepid Balanced Tip (Centurion Ozil handpiece), miCOR 700 half throttle (infusion/aspiration only), or full throttle (lens agitator engaged). After incision, the tip of each device was inserted into the anterior chamber and activated for 30 seconds. After euthanasia and enucleation, the corneas were removed, stained with trypan blue/alizarin red, and photographed in a standardized manner (5 ×400 magnification photographs from the center of each cornea). The ImageJ program was used to evaluate CEC damage and loss in the photographs. Results: The overall differences among the 3 groups regarding intact, damaged, and lost cells were statistically significant. However, by applying the Bonferroni correction, only the post hoc pairwise comparisons between groups 1 (phacoemulsification tip) and 2 (miCOR tip, half throttle, and without lens agitator engaged) were statistically significant regarding the 3 above-mentioned parameters. Conclusions: miCOR is a handheld, finger-controlled lens removal device with a blunt and rounded tip that vibrates at a low frequency, using mechanical agitation for nuclear disassembly. This acute rabbit study suggests CEC damage from the device, when the lens agitator is engaged is comparable with that of standard torsional phacoemulsification.Keywords
This publication has 15 references indexed in Scilit:
- Finger-controlled nonultrasonic lens extractorJournal of Cataract & Refractive Surgery, 2025
- First in-human clinical performance of a new non-cavitating handheld lensectomy system in 665 consecutive cataract surgeriesJournal of Cataract & Refractive Surgery, 2024
- Corneal endothelium protection provided by ophthalmic viscosurgical devices during phacoemulsification: experimental study in rabbit eyesJournal of Cataract & Refractive Surgery, 2022
- Effect of simulated lenticular debris on corneal endothelial cells: experimental study in rabbit eyesJournal of Cataract & Refractive Surgery, 2022
- Effect of longitudinal and torsional ultrasound on corneal endothelial cells: experimental study in rabbit eyesJournal of Cataract & Refractive Surgery, 2022
- Effect of phacoemulsification fluid flow on the corneal endothelium: experimental study in rabbit eyesJournal of Cataract & Refractive Surgery, 2021
- Carbon footprint and cost–effectiveness of cataract surgeryCurrent Opinion in Ophthalmology, 2016
- Microincisions in cataract surgeryJournal of Cataract & Refractive Surgery, 2014
- Increasing incidence of cataract surgery: Population-based studyJournal of Cataract & Refractive Surgery, 2013
- Effectiveness and safety of femtosecond laser–assisted lens fragmentation and anterior capsulotomy versus the manual technique in cataract surgeryJournal of Cataract & Refractive Surgery, 2013