JPJeff H. Pettey

Jeff H. Pettey

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jeff H. Pettey has a total of 146 co-authors. Here are the top co-authors by number of shared publications:

  • Randall J. Olson

    Department of Ophthalmology and Visual Sciences, John A Moran Eye Center, University of Utah, Salt Lake City, UT, USA

    13 shared publications
  • William R. Barlow

    Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA

    13 shared publications
  • Brian Zaugg

    Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, 65 Mario Capecchi Drive, Salt Lake City, Utah, 84132, USA

    8 shared publications
  • Brian Zaugg

    Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA

    8 shared publications
  • Randall J. Olson

    Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, USA

    7 shared publications
  • Ivan Cardenas

    Department of Ophthalmology and Visual Sciences, John A Moran Eye Center, University of Utah, Salt Lake City, UT, USA

    6 shared publications

Latest Publications

  • Open Access

    Comparing Post-Occlusion Surge at Decreasing Intraocular Pressures with Pressure Sensing Handpiece

    by Jessie A Montgomery, Coby Soule, Nathan Sherbotie, Ivan A Cardenas, Jenna L Jensen, Jacob A Bell, William R Barlow, Kolja Klug, Lincoln Wagner, Jeff H Pettey

    Purpose: To compare post-occlusion surge pressure at various intraocular pressures using the Active Sentry handpiece. Methods: This experimental (in vitro chamber) study used the Alcon Centurion platform and Active Sentry handpiece with balanced tips. Quad preset was used with settings: vacuum 500 mmHg, aspiration flow 50 mmHg, and IOPs of 30, 50, and 70 mmHg. A rubber disk was fixed within a sealed chamber fitted with an electric pressure sensor to monitor pressure changes. The phacoemulsification tip was inserted into the water-tight port of the pressure chamber, and the foot pedal was set to position two. The tip was put in contact with the disk to replicate tip occlusion and pulled from the disk to simulate occlusion break. Ten trials were performed at each IOP; pressure changes were recorded continuously. Results: At 70 mmHg IOP, average post-occlusion surge magnitude was 5.76 mmHg ± 0.54; average surge duration was 0.45 s ± 0.10. At 50 mmHg IOP, surge magnitude was 5.76 mmHg ± 1.15; surge duration surge was 0.52 s ± 0.23. At 30 mmHg IOP, surge magnitude was 10.46 mmHg ± 2.86; surge duration was 1.27 s ± 0.51. There was a statistically significant difference between surge magnitude and duration at 30 vs. 50 mmHg IOP (P < 0.05) and at 30 vs. 70 mmHg IOP (P < 0.05). Conclusion: When utilizing the Active Sentry handpiece, an increased surge risk was not observed when operative IOP was decreased from 70 mmHg to 50 mmHg. However, our data suggest that surge risk increases when operative IOP is decreased to 30 mmHg. The Active Sentry handpiece at 50 mmHg IOP would not introduce greater surge risk than at 70 mmHg IOP. Plain Language Summary: Cataracts are most frequently removed with a procedure called phacoemulsification. Though phacoemulsification is safe and effective, there are some serious risks, such as breakage of the eye’s back capsule. One of the events that can lead to this breakage is a post-occlusion surge, in which there is a drop in pressure after clearing of the blockage of the phaco probe. Because of this, it is important to use settings on the phacoemulsification machine that balance an “intraocular pressure” (pressure within the eye) that is high enough to decrease the risk of eye damage, but low enough to avoid excess internal eye inflammation. This study seeks to understand how a phacoemulsification handpiece that is designed to allow for tighter control of intraoperative intraocular pressure will impact post-occlusion surge when operating at lower intraocular pressures. Using a specially designed chamber, this handpiece was tested at different intraocular pressure settings: 30, 50, and 70 mmHg. We found that when using the handpiece at an intraocular pressure of 50 vs. 70 mmHg, there was no difference in post-occlusion surge. However, there was an increase in post-occlusion surge when using the handpiece at an intraocular pressure of 30 vs. 50 mmHg and 30 vs. 70 mmHg. This suggests that this handpiece can decrease post-occlusion surge down to an intraocular pressure of 50 mmHg, though it appears to lose this ability at an intraocular pressure between 30 and 50 mmHg.

  • Comparison of postocclusion surge between venturi and peristaltic phacoemulsification pump type

    by Coby Soule, Tyler Whitaker, Nathan Sherbotie, Jessie Montgomery, Kolja Klug, Lincoln Wagner, Jeff H. Pettey

    Purpose: To evaluate the postocclusion surge characteristics of venturi and peristaltic-generated vacuum levels. Setting: University setting, Salt Lake City, Utah. Design: Experimental study. Methods: The Johnson & Johnson Veritas machine and Ellips FX handpiece with standard pack tips, with variable peristaltic and venturi settings, were used. A standard quadrant removal preset had the settings: vacuum 450 mm Hg, aspiration 60 mm Hg, and bottle heights 41 cm and 81 cm. To monitor pressure changes, a rubber disk was fixed within a sealed chamber fitted with an electric sensor. The phacoemulsification tip was inserted through a small opening; the foot pedal was set to position 3. The tip was in contact with the disk to replicate tip occlusion and then pulled from the disk to simulate occlusion break. 10 trials were performed for each intraocular pressure and vacuum type. Results: A significant difference ( P < .01) was observed in postocclusion surge magnitude between venturi and peristaltic pumps at 41 cm and 81 cm bottle heights. No significant difference was observed in surge duration at either bottle height. Average duration of surge for venturi and peristaltic at 41 cm was 1.56 ± 0.75 seconds and 2.25 ± 0.40 seconds, respectively; at 81 cm 2.27 ± 1.41 seconds and 2.90 ± 1.10 seconds, respectively. Conclusions: Data suggest that at bottle heights of 41 cm and 81 cm, with indicated settings, venturi settings on the Veritas platform have a lower postocclusion surge magnitude compared with peristaltic settings. This indicates that there may be a platform-specific lower risk for posterior capsular tear when using venturi settings in the Veritas system during cataract surgery.


  • Open Access

    Energy Output Variability Among Phacoemulsification Tips Using Calorimetry

    by Ivan Cardenas, Reiker G Ricks, Jenna L Jensen, Tanner K Nelson, William Barlow, Randall J Olson, Jeff H Pettey

    Purpose: To determine if using different phacoemulsification (phaco) tips will impact thermal energy output utilizing calorimetry. Methods: The Alcon Centurion was used with the Infiniti OZil handpiece and balanced, hybrid, or MST Dewey A1 mini tip. Settings were 100% power, continuous torsional or longitudinal ultrasound, 0mmHg vacuum limit, and flow rate 12mL/min. Outflow tubing was removed from the handpiece and inflow tubing was manually occluded. The handpiece tip was placed into the calorimeter filled with 50mL of degassed deionized water and ultrasound was initiated for 1 minute. Temperature rise and cumulative dissipated energy (CDE) were recorded; ten trials were performed for each group. Results: Statistically significant differences in energy output, measured in Joules, were found between all three tips in both ultrasound modes. Balanced tips showed the highest output, Dewey tips had the lowest. Hybrid tips had significantly increased output in longitudinal mode, whereas Dewey tips had significantly decreased output in longitudinal mode. No significant differences were seen in CDE between tips in either ultrasound mode, but significant increases were seen in longitudinal mode within each tip. Conclusion: This study demonstrated differences in thermal energy production of three different phaco handpiece tips. This provides insight into how thermal injuries occur and what might cause these differences. Our methodology provides a novel way for accurate energy measurement at the tip, though it differs when compared to external energy production measurements. Surgeons should take into consideration the significant variability in thermal energy created by handpiece tips. Plain Language Summary: Modern cataract surgery employs phacoemulsification, a technique that breaks apart a cataract using ultrasonic energy. A rare but possible complication of this technology is thermal (heat) injury. Several factors contribute to energy generation during cataract fragmentation, such as friction at the incision site and impedance of flow rate. This study examines the thermal energy produced at the handpiece tip, where ultrasonic movement occurs. The energy delivered to the eye from the handpiece consists of mechanical energy in the form of kinetic and acoustic energy, leading to cavitation, mechanical disruption of the lens, and heat. It remains unclear how the design of phacoemulsification tips influences the energy transfer from piezoelectric crystals to the mechanical energy delivered to the eye. We used calorimetry to measure the thermal energy output, measured in Joules, between three different tips in longitudinal (forward and backward) and torsional (side to side) ultrasound modes, using the same settings, handpiece, and machine. The handpiece tip was submerged in the calorimetry chamber with water and operated for 60 seconds; a temperature probe measured the temperature change. The temperature changes were converted to energy and compared, and the energy measurement generated by the machine was recorded. We found significant differences in energy output between the three tips in both ultrasound modes, the Dewey tip demonstrated the lowest energy output and the balanced tip had the highest, in torsional and longitudinal mode. We found the measured energy differed significantly from the machine-generated measurement. These findings highlight the variability in energy output and expand on the potential contributing factors to energy generation and thermal injury in cataract surgery.

  • Effect of Interview Cap on Ophthalmology Residency Match: A San Francisco Match Analysis

    by Muhammad Jehanzeb Khan, Muhammad Ali, Sabit Ahmed, Malik Muhammad Hamza Khan, Laura K. Green, Alice Lorch, Jules Winokur, Jeff H. Pettey, R. Michael Siatkowski, Fasika Woreta


  • Evaluation of corneal endothelium damage with a new handheld fragmentation device

    by Liliana Werner, Neil Kelkar, Kevin Eid, Reiker G. Ricks, Emilie L Ungricht, Jeff H. Pettey

    Purpose: To quantify damage to corneal endothelial cells (CECs) from a new handheld lens fragmentation device and compare it with damage from a standard phacoemulsification device. Setting: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah. Design: Experimental study. Methods: 15 New Zealand white rabbits received bilateral surgery. Their eyes were divided into 3 groups (10 eyes/group): Intrepid Balanced Tip (Centurion Ozil handpiece), miCOR 700 half throttle (infusion/aspiration only), or full throttle (lens agitator engaged). After incision, the tip of each device was inserted into the anterior chamber and activated for 30 seconds. After euthanasia and enucleation, the corneas were removed, stained with trypan blue/alizarin red, and photographed in a standardized manner (5 ×400 magnification photographs from the center of each cornea). The ImageJ program was used to evaluate CEC damage and loss in the photographs. Results: The overall differences among the 3 groups regarding intact, damaged, and lost cells were statistically significant. However, by applying the Bonferroni correction, only the post hoc pairwise comparisons between groups 1 (phacoemulsification tip) and 2 (miCOR tip, half throttle, and without lens agitator engaged) were statistically significant regarding the 3 above-mentioned parameters. Conclusions: miCOR is a handheld, finger-controlled lens removal device with a blunt and rounded tip that vibrates at a low frequency, using mechanical agitation for nuclear disassembly. This acute rabbit study suggests CEC damage from the device, when the lens agitator is engaged is comparable with that of standard torsional phacoemulsification.

  • Open Access

    Comparison of Postocclusion Pressure Surge Between Pressure Sensing and Traditional Phacoemulsification Handpieces

    by Tyler Whitaker, Tanner K. Nelson, Reiker G. Ricks, Kolja Klug, Ivan A. Cardenas, Randall J. Olson, Jeff H. Pettey

    Purpose: To compare the Active Sentry and OZil handpieces regarding their ability to prevent postocclusion surge. Setting: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah. Design: Experimental study. Methods: This study used the Alcon Centurion surgical platform, with both OZil handpieces fitted with balanced tips. The quad preset was used with a vacuum of 500 mmHg, an aspiration flow of 50 mmHg, and an intraocular pressure (IOP) of 70 mmHg. A rubber disk was fixed within a sealed chamber fitted with an electric pressure sensor to monitor pressure changes. The phaco tip was inserted through a small opening, and the foot pedal was set to position two. The tip was put in contact with the fixed rubber disk to replicate tip occlusion and then pulled from the disk to simulate occlusion break. 10 trials were performed with each handpiece, and pressure changes were recorded electronically. Results: A significant difference ( p < 0.01) was found between the magnitude of postocclusion surge, as well as between the duration of postocclusion surge. Conclusion: The Active Sentry handpiece was found to have a decreased magnitude and shorter duration of postocclusion surge compared with the OZil, signifying that having the pressure sensor in the handpiece allows it to react to post‐occlusion surge more quickly and to decrease surge magnitude.


  • Open Access

    Comparison of Ultrasound Energy Delivered to the Anterior Segment Across Different Phacoemulsification Surgical Platforms

    by Tanner K Nelson, Reiker G Ricks, Ivan Cardenas, Tyler Whitaker, Jenna L Jensen, Randall J Olson, Jeff H Pettey

    Purpose: The aim of this study was to use calorimetry to understand the difference in energy transferred by three phacoemulsification surgical platforms to the eye. Patients and Methods: A phacoemulsification tip was lowered into a double-walled calorimeter filled with distilled water. The foot pedal was depressed for 30 seconds and the change in temperature of the water was measured by a temperature probe. Three phacoemulsification systems were compared: the Alcon Centurion, Johnson & Johnson Veritas and Oertli CataRhex 3. The following conditions remained constant across trials and platforms: continuous longitudinal ultrasound, flow rate 12mL/min, vacuum 0mmHg, and clamped inflow and outflow tubing. The different platforms were directly compared at 20%, 40%, 60%, 80% and 100% power. Results: A two-way ANOVA found a significant difference (P < 0.001) in overall energy output across all trials between the CataRhex 3, Centurion and Veritas with an F value of 63.97 and two degrees of freedom. Conclusion: Given identical settings, the amount of energy produced was significantly different across phacoemulsification platforms. This data can aid surgeons’ understanding of how power level by surgical platform can impact the amount of energy introduced into the anterior segment during cataract surgery. Plain Language Summary: Cataract surgery is one of the most commonly performed surgical procedures in the United States. The most common surgical technique used to remove cataracts is called phacoemulsification (phaco), which utilizes ultrasound energy to break up and remove cataracts. Utilizing phaco to emulsify cataracts is safe and effective; however, because of the delicate nature of the structures in the eye, the amount of ultrasound energy delivered during the surgery is an important consideration to avoid adverse outcomes. There are a variety of phaco platforms (machines) used for cataract surgery. While it is beneficial for surgeons to have many options of surgical platforms, proprietary engineering makes it difficult to know how these surgical platforms compare to one another, especially in important variables such as energy delivery to the eye. To date, it has been unknown how the amount of energy delivered by these phaco platforms differs, if at all, when using identical settings during surgery. We did this study to find out if there are energy differences. To do this research, our lab used calorimetry, which is a way of measuring energy transfer, to compare three different surgical platforms at the same settings. We found a statistically significant difference in amount of energy between these surgical platforms. These results are important because they may help surgeons to understand that the amount of energy delivered during cataract surgery will be different depending on which surgical platform they are using and help to prevent adverse outcomes caused by delivering too much energy to the eye.


  • Open Access

    Gender representation of presenters at American Academy of Ophthalmology conferences from 2004-2019

    by Eleanor Burton, Chase Paulson, Ayesha Patil, Ruby Garcia, Sydni Johnson, Josie White, Adriana Rush, Devin Eddington, Jeff H. Pettey, Rachel G. Simpson

    Importance: Gender equity is an important topic in medicine and accurate trends are essential to evaluate historical, current, and future trends. Objective: To describe changes in gender representation at American Academy of Ophthalmology (AAO) meetings from 2004 to 2019. Participants: Presenters at the American Academy of Ophthalmology meetings from 2004 to 2019. Design & Setting: This is a retrospective cross-sectional study. Data was extracted using AAO annual and subspecialty meeting archives for every third year between 2004 and 2019. Sessions were stratified by category and subspecialty. Poster sessions were excluded. Gender was considered binary and determined using pronouns or photographs from professional websites when available and the gender-api name tool when individual information was not available. Main outcome measures: Proportion of gender of the presenters at the American Academy of Ophthalmology within respective specialties with a focus on surgical vs clinical sessions. Results: The proportion of female presenters at AAO meetings increased between 2004 and 2019 from 13% to 29%. The largest changes were observed for oncology (net +28%, 1.85%/year increase, OR 1.09) and oculoplastics (+25%, 1.66%/year increase, OR 1.106). For surgical sessions, the increase in proportion of female speakers fell short of the overall increase in representation in comprehensive (+16% overall vs. +13% for surgical sessions), glaucoma (11% vs. 7%), and pediatrics (+17% vs. -1%). The increase in female representation among surgical session presenters did not exceed the overall increase for any subspecialty. For clinical sessions, the proportion of female leaders exceeded the overall increase in cornea (20% cornea vs. 13% overall), neuro-ophthalmology (15% vs. 9%), and pediatrics (35% vs. 17%). Conclusions: Female representation among presenters at the AAO annual and subspecialty meetings increased between 2004 and 2019 for all subspecialties. For many subspecialties, there was a proportionally slower rate of increase in female representation among surgical session presenters and faster rate of increase for clinical sessions.

  • Open Access

    Discrepancies in CDE and Measured Phaco Tip Energy: Comparison of Energy Produced in Longitudinal and Torsional Ultrasound Using Calorimetry

    by Reiker G Ricks, Ivan Cardenas, Jenna L Jensen, Tanner K Nelson, Randall J Olson, Jeff H Pettey

    Purpose: This study aims to investigate the differences between the heat energy produced during cataract surgery and Cumulative dissipated energy (CDE). CDE is often used as a medium for understanding the energy delivered to the eye during cataract surgery. However, the actual energy produced at the tip level of the tip is not well understood. We propose that a discrepancy may exist between the CDE reported by the surgical machine and the actual energy delivered to the eye. Methods: About 50 mL of distilled water were degassed and placed in an isobaric calorimeter. Using the Alcon Centurion and Ozil handpiece fitted with the balanced tip, an investigator immersed the phaco tip into the water and pressed the foot pedal to position 3. The device was set to 100% continuous power, vacuum to 0 mmHg, with aspiration 12 mL/min aspiration. To prevent system changes in the system within the calorimeter, the aspiration tubing was occluded. Temperature change recorded by another investigator was observed from 0 to 60 seconds. After 60 seconds the first researcher immediately released the pedal and removed the phaco tip from the water. Trials were performed 10 times using solely torsional or longitudinal settings and averaged. CDE also was recorded and averaged. Results: No significant difference was seen in the temperature change or energy calculated in Joules between ultrasound modalities, with torsional producing a magnitude of 163 J and longitudinal producing 172 J (P = 0.2). However, the CDE generated in the 60 seconds period was significantly different, with a magnitude of 61 for longitudinal compared to 24 for torsional (P < 0.001). Conclusion: Significantly more energy was generated using torsional ultrasound than longitudinal at the tip level of the tip. CDE did not appear to accurately reflect these differences. This suggests that other factors should be considered when evaluating CDE and surgical outcomes. Plain Language Summary: This study looked at possible differences between the energy generated during cataract surgery that is reported by the surgical device and the actual energy measured as thermal heat using different machine settings, namely longitudinal and torsional ultrasound. A common metric used for energy delivery to the eye is cumulative dissipated energy. The problem is that this measure accounts for the energy delivered to the eye where the surgical instrument passes through the cornea. Energy that is produced by the rest of the instrument that is inside the eye is less understood, although others have studied postoperative outcomes. We used a method called calorimetry to measure the thermal heat produced by the entire tip and compared this to what the machine reported as cumulative dissipated energy. Calorimetry calculates energy by measuring the change in temperature of liquids. The surgical instrument generated heat in a chamber containing water, and we used the change in temperature to calculate the energy produced by the surgical instrument. We found that longitudinal and torsional ultrasound produced similar heat energy, but the machine reported very different energy. Our results suggest that the machine may not be reporting all of the energy which the surgical instrument produces, and that surgeons may not be able to rely on cumulative dissipated energy to predict operative outcomes.