End-Tidal CO2-Arterial CO2 Differences: A Useful Intraoperative Mortality Marker in Trauma Surgery
- 1 November 2003
- journal article
- research article
- Published by Wolters Kluwer Health
- Vol. 55 (5) , 892-897
Abstract
Objective The gradient of end-tidal CO2 to arterial CO2 (Pa-ET)CO2 has been identified as a predictor of mortality in patients undergoing emergency trauma surgery. In an effort to further elucidate this phenomena, we accumulated additional data on trauma patients undergoing emergency surgery. Methods Five-hundred and one patients undergoing emergent trauma surgery at an Urban Level I Trauma Center were used as a database. Data were obtained both prospectively and retrospectively. End-tidal and CO2 measurements were serially obtained during surgery. Data were arbitrarily placed in three categories: initial OR, post-resuscitation, and final OR. (Post-resuscitation was identified after bleeding controlled and vital signs normalizing). Correlation of the end-tidal CO2 with the PACO2 difference were correlated with various factors including survival. Results Overall mortality was 29%. Mean ISS was 22 ± 9.8. Mean emergency department systolic blood pressure was 81 mm Hg. Sixty-three people died in the operating room, 54 died within 24 hours post-op, and 30 patients died greater than 24 hours post-op. The average (Pa-ET)CO2 difference was 10 mm Hg in non-survivors in patients that died at all time intervals. Conclusion (Pa-ET)CO2 can be used as a predictor of mortality and may be useful as an intraoperative tool for assessing the physiologic conditions of the patient. This predictor of mortality was valid even in patients that died greater than 24 hours after surgery. This information is almost always already available and may be used to further guide the decisions regarding patient care, particularly in decisions regarding damage control surgery.Keywords
This publication has 13 references indexed in Scilit:
- End-Tidal CO2-Derived Values during Emergency Trauma Surgery Correlated with Outcome: A Prospective Study2002
- Intraoperative End-Tidal Carbon Dioxide Levels and Derived Calculations Correlated with Outcome in Trauma PatientsThe Journal of Trauma: Injury, Infection, and Critical Care, 1996
- End-tidal carbon dioxide during extremely low cardiac outputAnnals of Emergency Medicine, 1994
- The end‐tidal carbon dioxide detector Assessment of a new method to distinguish oesophageal from tracheal intubationAnaesthesia, 1990
- End-Tidal Carbon Dioxide Monitoring During Cardiopulmonary ResuscitationJAMA, 1989
- End-Tidal Carbon Dioxide Concentration during Cardiopulmonary ResuscitationNew England Journal of Medicine, 1988
- Esophageal IntubationAnesthesia & Analgesia, 1986
- Intraoperative events diagnosed by expired carbon dioxide monitoring in childrenCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1986
- THE EXPIRED CARBON DIOXIDE AS A CONTINUOUS GUIDE OF THE PULMONARY AND CIRCULATORY SYSTEMS DURING ANESTHESIA AND SURGERYThe Journal of Thoracic and Cardiovascular Surgery, 1961
- Respiratory dead space and arterial to end-tidal CO2 tension difference in anesthetized manJournal of Applied Physiology, 1960