Design of a computer-controlled multileaf collimator for advanced electron radiotherapy
Authors:
- T GauerTGT Gauer
- D AlbersDAD Albers
- F CremersFCF Cremers
- R HarmansaRHR Harmansa
- R PellegriniRPR Pellegrini
- R SchmidtRSR Schmidt
- 30 October 2006
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 51 (23) , 5987-6003
Abstract
A multileaf collimator for electrons (eMLC) has been designed that fulfils the technical requirements for providing advanced irradiation techniques with electrons. In the present work, the basic design parameters of leaf material, leaf height, leaf width and number of leaves as well as leaf overtravel and leaf shape were determined such that an eMLC with motorized leaves can be manufactured by a company specialized in MLC technology. For this purpose, a manually driven eMLC with variable source-to-collimator distance (SCD) was used to evaluate the chosen leaf specification and investigate the impact of the SCD on the off-axis dose distribution. In order to select the final SCD of the eMLC, a compromise had to be found between maximum field size, minimum beam penumbra and necessary distance between eMLC and isocentre to eliminate patient realignments during gantry rotation. As a result, the eMLC is placed according to the target position at 72 and 84 cm SCD, respectively. This feature will be achieved by interchangeable distance holders. At these SCDs, the corresponding maximum field sizes at 100 cm source-to-isocentre distance are 20 x 20 cm and 17 x 17 cm, respectively. Finally, the off-axis dose distribution at the maximum opening of the eMLC was improved by fine-tuning the settings of the accelerator jaws and introducing trimmer bars above the eMLC. Following this optimization, a prototype eMLC consisting of 2 x 24 computer-controlled brass leaves is manufactured by 3D Line Medical Systems.Keywords
This publication has 16 references indexed in Scilit:
- Energy modulated electron therapy using a few leaf electron collimator in combination with IMRT and 3D‐CRT: Monte Carlo‐based planning and dosimetric evaluationMedical Physics, 2005
- Monte Carlo based modulated electron beam treatment planning using a few-leaf electron collimator—feasibility studyPhysics in Medicine & Biology, 2005
- Effect of processing time delay on the dose response of Kodak EDR2 filmMedical Physics, 2004
- A preliminary study of the role of modulated electron beams in intensity modulated radiotherapy, using automated beam orientation and modality selectionInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2004
- Dosimetry of a prototype retractable eMLC for fixed-beam electron therapyMedical Physics, 2004
- Monte Carlo based treatment planning for modulated electron beam radiation therapyPhysics in Medicine & Biology, 2001
- Monte Carlo and experimental investigations of multileaf collimated electron beams for modulated electron radiation therapyMedical Physics, 2000
- Possibilities for tailoring dose distributions through the manipulation of electron beam characteristicsPhysics in Medicine & Biology, 1997
- Optimization of 3D conformal electron beam therapy in inhomogeneous media by concomitant fluence and energy modulationPhysics in Medicine & Biology, 1997
- Optimization of conformal electron beam therapy using energy‐ and fluence‐modulated beamsMedical Physics, 1996