Latest Publications
- Open Access
- 1 March 2013
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 106, S344
PO-0889: Clinical use of an add electron MLC in radiotherapy of skin and breast cancer
- 1 March 2013
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 106, S344
Open AccessPO-0889: Clinical use of an add electron MLC in radiotherapy of skin and breast cancer
- Open Access
Approximated segmentation considering technical and dosimetric constraints in intensity-modulated radiation therapy with electrons
In intensity-modulated radiation therapy, optimal intensity distributions of incoming beams are decomposed into linear combinations of leaf openings of a multileaf collimator (segments). In order to avoid inefficient dose delivery, the decomposition should satisfy a number of dosimetric constraints due to suboptimal dose characteristics of small segments. However, exact decomposition with dosimetric constraints is only in limited cases possible. The present work introduces new heuristic segmentation algorithms for the following optimization problem: Find a segmentation of an approximated matrix using only allowed fields and minimize the approximation error. Finally, the decomposition algorithms were implemented into an optimization programme in order to examine the assumptions of the algorithms for a clinical example. As a result, identical dose distributions with much fewer segments and a significantly smaller number of monitor units could be achieved using dosimetric constraints. Consequently, the dose delivery is more efficient and less time consuming.
Open AccessApproximated segmentation considering technical and dosimetric constraints in intensity-modulated radiation therapy with electrons
In intensity-modulated radiation therapy, optimal intensity distributions of incoming beams are decomposed into linear combinations of leaf openings of a multileaf collimator (segments). In order to avoid inefficient dose delivery, the decomposition should satisfy a number of dosimetric constraints due to suboptimal dose characteristics of small segments. However, exact decomposition with dosimetric constraints is only in limited cases possible. The present work introduces new heuristic segmentation algorithms for the following optimization problem: Find a segmentation of an approximated matrix using only allowed fields and minimize the approximation error. Finally, the decomposition algorithms were implemented into an optimization programme in order to examine the assumptions of the algorithms for a clinical example. As a result, identical dose distributions with much fewer segments and a significantly smaller number of monitor units could be achieved using dosimetric constraints. Consequently, the dose delivery is more efficient and less time consuming.
- 31 March 2010
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 94 (3) , 313-318
Comparison of electron IMRT to helical photon IMRT and conventional photon irradiation for treatment of breast and chest wall tumours
- 31 March 2010
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 94 (3) , 313-318
Comparison of electron IMRT to helical photon IMRT and conventional photon irradiation for treatment of breast and chest wall tumours
- 1 February 2008
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 53 (4) , 1071-1085
Characterization of an add-on multileaf collimator for electron beam therapy
An add-on multileaf collimator for electrons (eMLC) has been developed that provides computer-controlled beam collimation and isocentric dose delivery. The design parameters result from the design study by Gauer et al (2006 Phys. Med. Biol. 51 5987-6003) and were configured such that a compact and light-weight eMLC with motorized leaves can be industrially manufactured and stably mounted on a conventional linear accelerator. In the present study, the efficiency of an initial computer-controlled prototype was examined according to the design goals and the performance of energy- and intensity-modulated treatment techniques. This study concentrates on the attachment and gantry stability as well as the dosimetric characteristics of central-axis and off-axis dose, field size dependence, collimator scatter, field abutment, radiation leakage and the setting of the accelerator jaws. To provide isocentric irradiation, the eMLC can be placed either 16 or 28 cm above the isocentre through interchangeable holders. The mechanical implementation of this feature results in a maximum field displacement of less than 0.6 mm at 90 degrees and 270 degrees gantry angles. Compared to a 10 x 10 cm applicator at 6-14 MeV, the beam penumbra of the eMLC at a 16 cm collimator-to-isocentre distance is 0.8-0.4 cm greater and the depth-dose curves show a larger build-up effect. Due to the loss in energy dependence of the therapeutic range and the much lower dose output at small beam sizes, a minimum beam size of 3 x 3 cm is necessary to avoid suboptimal dose delivery. Dose output and beam symmetry are not affected by collimator scatter when the central axis is blocked. As a consequence of the broader beam penumbra, uniform dose distributions were measured in the junction region of adjacent beams at perpendicular and oblique beam incidence. However, adjacent beams with a high difference in a beam energy of 6 to 14 MeV generate cold and hot spots of approximately 15% in the abutting region. In order to improve uniformity, the energy of adjacent beams must be limited to 6 to 10 MeV and 10 to 14 MeV respectively. At the maximum available beam energy of 14 MeV, radiation leakage results mainly from the intraleaf leakage of approximately 2.5% relative dose which could be effectively eliminated at off-axis distances remote from the field edge by adjusting the jaw field size to the respective opening of the eMLC. Additionally, the interleaf and leaf-end leakage could be reduced by using a tongue-and-groove leaf shape and adjoining the leaf-ends off-axis respectively.
- 1 February 2008
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 53 (4) , 1071-1085
Characterization of an add-on multileaf collimator for electron beam therapy
An add-on multileaf collimator for electrons (eMLC) has been developed that provides computer-controlled beam collimation and isocentric dose delivery. The design parameters result from the design study by Gauer et al (2006 Phys. Med. Biol. 51 5987-6003) and were configured such that a compact and light-weight eMLC with motorized leaves can be industrially manufactured and stably mounted on a conventional linear accelerator. In the present study, the efficiency of an initial computer-controlled prototype was examined according to the design goals and the performance of energy- and intensity-modulated treatment techniques. This study concentrates on the attachment and gantry stability as well as the dosimetric characteristics of central-axis and off-axis dose, field size dependence, collimator scatter, field abutment, radiation leakage and the setting of the accelerator jaws. To provide isocentric irradiation, the eMLC can be placed either 16 or 28 cm above the isocentre through interchangeable holders. The mechanical implementation of this feature results in a maximum field displacement of less than 0.6 mm at 90 degrees and 270 degrees gantry angles. Compared to a 10 x 10 cm applicator at 6-14 MeV, the beam penumbra of the eMLC at a 16 cm collimator-to-isocentre distance is 0.8-0.4 cm greater and the depth-dose curves show a larger build-up effect. Due to the loss in energy dependence of the therapeutic range and the much lower dose output at small beam sizes, a minimum beam size of 3 x 3 cm is necessary to avoid suboptimal dose delivery. Dose output and beam symmetry are not affected by collimator scatter when the central axis is blocked. As a consequence of the broader beam penumbra, uniform dose distributions were measured in the junction region of adjacent beams at perpendicular and oblique beam incidence. However, adjacent beams with a high difference in a beam energy of 6 to 14 MeV generate cold and hot spots of approximately 15% in the abutting region. In order to improve uniformity, the energy of adjacent beams must be limited to 6 to 10 MeV and 10 to 14 MeV respectively. At the maximum available beam energy of 14 MeV, radiation leakage results mainly from the intraleaf leakage of approximately 2.5% relative dose which could be effectively eliminated at off-axis distances remote from the field edge by adjusting the jaw field size to the respective opening of the eMLC. Additionally, the interleaf and leaf-end leakage could be reduced by using a tongue-and-groove leaf shape and adjoining the leaf-ends off-axis respectively.
- 11 June 2007
- Published by Wiley in Medical Physics
- Vol. 34 (6Part9) , 2436
SU-FF-T-153: Development of An Electron Multileaf Collimator Performing Computer-Controlled Beam Collimation and Isocentric Dose Delivery with Electrons
- 11 June 2007
- Published by Wiley in Medical Physics
- Vol. 34 (6Part9) , 2436
SU-FF-T-153: Development of An Electron Multileaf Collimator Performing Computer-Controlled Beam Collimation and Isocentric Dose Delivery with Electrons
- 30 October 2006
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 51 (23) , 5987-6003
Design of a computer-controlled multileaf collimator for advanced electron radiotherapy
A multileaf collimator for electrons (eMLC) has been designed that fulfils the technical requirements for providing advanced irradiation techniques with electrons. In the present work, the basic design parameters of leaf material, leaf height, leaf width and number of leaves as well as leaf overtravel and leaf shape were determined such that an eMLC with motorized leaves can be manufactured by a company specialized in MLC technology. For this purpose, a manually driven eMLC with variable source-to-collimator distance (SCD) was used to evaluate the chosen leaf specification and investigate the impact of the SCD on the off-axis dose distribution. In order to select the final SCD of the eMLC, a compromise had to be found between maximum field size, minimum beam penumbra and necessary distance between eMLC and isocentre to eliminate patient realignments during gantry rotation. As a result, the eMLC is placed according to the target position at 72 and 84 cm SCD, respectively. This feature will be achieved by interchangeable distance holders. At these SCDs, the corresponding maximum field sizes at 100 cm source-to-isocentre distance are 20 x 20 cm and 17 x 17 cm, respectively. Finally, the off-axis dose distribution at the maximum opening of the eMLC was improved by fine-tuning the settings of the accelerator jaws and introducing trimmer bars above the eMLC. Following this optimization, a prototype eMLC consisting of 2 x 24 computer-controlled brass leaves is manufactured by 3D Line Medical Systems.
- 30 October 2006
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 51 (23) , 5987-6003
Design of a computer-controlled multileaf collimator for advanced electron radiotherapy
A multileaf collimator for electrons (eMLC) has been designed that fulfils the technical requirements for providing advanced irradiation techniques with electrons. In the present work, the basic design parameters of leaf material, leaf height, leaf width and number of leaves as well as leaf overtravel and leaf shape were determined such that an eMLC with motorized leaves can be manufactured by a company specialized in MLC technology. For this purpose, a manually driven eMLC with variable source-to-collimator distance (SCD) was used to evaluate the chosen leaf specification and investigate the impact of the SCD on the off-axis dose distribution. In order to select the final SCD of the eMLC, a compromise had to be found between maximum field size, minimum beam penumbra and necessary distance between eMLC and isocentre to eliminate patient realignments during gantry rotation. As a result, the eMLC is placed according to the target position at 72 and 84 cm SCD, respectively. This feature will be achieved by interchangeable distance holders. At these SCDs, the corresponding maximum field sizes at 100 cm source-to-isocentre distance are 20 x 20 cm and 17 x 17 cm, respectively. Finally, the off-axis dose distribution at the maximum opening of the eMLC was improved by fine-tuning the settings of the accelerator jaws and introducing trimmer bars above the eMLC. Following this optimization, a prototype eMLC consisting of 2 x 24 computer-controlled brass leaves is manufactured by 3D Line Medical Systems.