Charge Collection in SOI Microdosimeters and Their Radiation Hardness
- 3 February 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (4) , 568-574
Abstract
A new batch of microdosimeters has been extensively studied for their charge collection efficiency (CCE) properties, as well as their radiation hardness for medical, space and accident applications. Silicon-on-insulator (SOI) microdosimeters with an active layer thickness of 10, 20 and 50 μm have been investigated and were characterized with a 24 MeV carbon ion beam as well as a Co-60 gamma source. A negative pulse was observed in addition to the positive pulses generated within the sensitive volumes (SVs) by incident ions which led to undesirable low energy events in the SOI microdosimeters response. To study this phenomenon, the microdosimeters were irradiated with gamma radiation from a Co-60 source with a total dose of 3 and 10 Mrad(Si). It was determined that the negative pulse was originating from the support wafer due to the displacement current phenomenon. Irradiation with the Co-60 source led to a disappearing of the negative pulse due to an increase in recombination within the support wafer while almost no changes in CCE were observed. A radiation hardness study was also performed on the 50 μm SOI microdosimeter with 16 SVs being irradiated with a fluence of ~ 10 8 12 C ions/cm 2 . A CCE deficit of approximately 2% was observed at an operation bias of 10V within the SVs. The findings of this work demonstrate that the SOI microdosimeters can be utilized in space and medical applications as they can handle typical levels of dose encountered in these applications. Additionally, evidence for SOI microdosimeter fabrication standards in terms of support wafer resistivity and buried oxide (BOX) thickness is shown.Keywords
Funding Information
- Australian Research Council (DP170102273)
- European Space Agency (ESA) Technology Research Program (4000133574/21/NL/CRS)
This publication has 23 references indexed in Scilit:
- The relative biological effectiveness for carbon, nitrogen, and oxygen ion beams using passive and scanning techniques evaluated with fully 3D silicon microdosimetersMedical Physics, 2018
- Characterization of proton pencil beam scanning and passive beam using a high spatial resolution solid‐state microdosimeterMedical Physics, 2017
- 3D cylindrical silicon microdosimeters: fabrication, simulation and charge collection studyJournal of Instrumentation, 2015
- Displacement Damage Effects in Irradiated Semiconductor DevicesIEEE Transactions on Nuclear Science, 2013
- A Review of Update Clinical Results of Carbon Ion RadiotherapyJapanese Journal of Clinical Oncology, 2012
- A Cylindrical Silicon-on-Insulator Microdosimeter: Charge Collection CharacteristicsIEEE Transactions on Nuclear Science, 2008
- Radiation damage in silicon detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003
- Charge collection in SOI capacitors and circuits and its effect on SEU hardnessIEEE Transactions on Nuclear Science, 2002
- Shuttle Radiation Dose Measurements in the International Space Station Orbits1Radiation Research, 2002
- Solid state microdosimetryNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2001