MPMarco Povoli

Marco Povoli

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Marco Povoli has a total of 201 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Improving UV Stability of SiO2/SiNx-Passivated Silicon Photodiodes Through Shallow Junction Implantation and Oxide Regrowth

    by Michael N. Getz, Ozhan Koybasi, Fredrik Edhborg, Ørnulf Nordseth, Steven Hesse, Tobias Pohl, Marco Povoli, Stefan Källberg, Lutz Werner, Erkki Ikonen, et al.

    Induced-junction silicon photodiodes based on SiO2/SiNx surface passivation are attractive for high-accuracy radiometry, but their use in the deep ultraviolet is limited by UV-induced degradation of the dielectric stack. In this work, we investigate the degradation of SiO2/SiNx-passivated p-type silicon photodiodes under UV irradiation and evaluate strategies for improving stability through shallow implanted junctions and oxide processing. Capacitance–voltage measurements on MIS capacitors and lifetime measurements on symmetrically passivated wafers show that UV exposure causes a rapid reduction in effective dielectric charge and carrier lifetime, followed by saturation at higher dose, consistent with filling of a finite population of electrically active trap states. Induced-junction photodiodes exhibit rapid photocurrent loss at 222 nm and, in some cases, eventual collapse, indicating that the remaining effective dielectric charge is insufficient to sustain the induced junction. To maintain junction functionality after UV exposure, shallow As- and Sb-implanted junctions are employed, resulting in an initial reduction during 222 nm exposure followed by stabilization at around 80–85% of the initial value up to the highest tested dose of 200 J/cm2. Further improvement is achieved by stripping and regrowing the implanted screen oxide before SiNx deposition, yielding nearly unchanged photocurrent after prolonged 222 nm exposure up to ca. 500 J/cm2. These results show that UV stability can be substantially improved by reducing device dependence on dielectric-induced inversion and by improving post-implantation interfacial oxide quality.

  • Open Access

    Solid State microdosimetry for particle therapy: 25 years of developments at Centre for Medical Radiation Physics

    by Linh T. Tran, Vladimir Pan, James Vohradsky, Marco Petasecca, Michael Lerch, Marco Povoli, Angela Kok, Dirk Wagenaar, Stefan Both, Taku Inaniwa, et al.

  • Investigation of Graphene as a Shielding Material for Space Environments

    by Abdelrahman M. BaniHani, Dylan Hill, Vladimir Pan, James Vohradsky, Daniel Bennett, David Bolst, Stefania Peracchi, Marco Povoli, Angela Kok, Sung Hyun Lee, et al.

    This work investigates the radiation shielding efficiency of High-Density Polyethylene (HDPE)/Graphene, carbon fibre, and polyethylene materials. The composite HDPE Graphene was studied both as a substitute layer in the ISS wall/Columbus shielding configuration and as an additional layer serving as intravehicular spacesuits for astronauts. The average quality factors (Q) for 12C, 40Ar, and 56Fe ion beams were evaluated using the Silicon-On-Insulator (SOI) Mushroom microdosimeter behind various realistic ISS Columbus wall configurations at the Heavy Ion Medical Accelerator in Chiba (HIMAC), Japan. Moreover, the individual dose equivalent, Hp(10), was calculated for astronaut personal monitoring. The SOI microdosimeter’s response to the monoenergetic ion beams behind these shielding configurations enabled comparison of the shielding efficiencies for the tested materials. The results indicate that the shielding efficiency of HDPE Graphene is similar to that of carbon fibre and Kevlar.

  • Open Access

    Microdosimetry of Very-High-Energy Heavy Ion Beams for Electronics Testing Using Silicon-on-Insulator Detectors

    by Andreas Waets, Natalia Emriskova, Ruben Garcia Alia, Karolina Klimek, Vladimir Pan, Anatoly Rosenfeld, Linh T. Tran, James Vohradsky, Angela Kok, Marco Povoli, et al.

    This paper explores the use of microdosimetry with a silicon-on-insulator (SOI) detector for characterizing very-high-energy (VHE), heavy ion beams used specifically for single event effect (SEE) testing of electronics. The detector was deployed at CERN’s heavy ion facility for radiation effects testing and exposed to lead ion beams in the 100 – 1000 MeV per nucleon kinetic energy range. The implications and possible benefits of using microdosimetry for SEE testing purposes are discussed.


  • Evidence of charge multiplication in thin 25 μm × 25 μm pitch 3D silicon sensors

    by A. Gentry, M. Boscardin, M. Hoeferkamp, M. Povoli, S. Seidel, J. Si, G.-F. Dalla Betta

    Characterization measurements of 25 μm × 25 μm pitch 3D silicon sensors are performed, for devices with active thickness of 150 μm. Evidence of charge multiplication caused by impact ionization below the breakdown voltage is observed in sensors operated at -45 ∘C. Small-pitch 3D silicon sensors have potential as high precision 4D tracking detectors that are also able to withstand radiation fluences beyond 1016 neq/cm2. This is applicable for use at future facilities such as the High-Luminosity Large Hadron Collider and the Future Circular Collider. Characteristics of these devices are compared to those of similar sensors of pitch 50 μm × 50 μm, showing comparable charge collection at low voltage, and acceptable leakage current, depletion voltage, breakdown voltage, and capacitance despite the extremely small cell size. The unirradiated 25 μm × 25 μm sensors exhibit charge multiplication above about 90 V reverse bias, while, as predicted, no multiplication is observed in the 50 μm × 50 μm sensors below their breakdown voltage. The maximum gain observed below breakdown is 1.33.


  • LURAD: Design study of a comprehensive radiation monitor package for the gateway and the lunar surface

    by C. Potiriadis, K. Karafasoulis, C. Papadimitropoulos, E. Papadomanolaki, A. Papangelis, I. Kazas, J. Vourvoulakis, G. Theodoratos, A. Kok, L.T. Tran, et al.


  • Open Access

    LURAD: Design Study of a Comprehensive Radiation Monitor Package for the Gateway and the Lunar Surface

    by C. Potiriadis, K. Karafasoulis, C. Papadimitropoulos, E. Papadomanolaki, A. Papangelis, I. Kazas, J. Vourvoulakis, G. Theodoratos, A. Kok, L. T. Tran, et al.

    Moon is an auspicious environment for the study of Galactic cosmic rays (GCR) and Solar particle events (SEP) due to the absence of magnetic field and atmosphere. The same characteristics raise the radiation risk for human presence in orbit around it or at the lunar surface. The secondary (albedo) radiation resulting from the interaction of the primary radiation with the lunar soil adds an extra risk factor, because neutrons are produced, but also it can be exploited to study the soil composition. In this paper, the design of a comprehensive radiation monitor package tailored to the lunar environment is presented. The detector, named LURAD, will perform spectroscopic measurements of protons, electrons, heavy ions, as well as gamma-rays, and neutrons. A microdosimetry monitor subsystem is foreseen which can provide measurements of LET(Si) spectra in a wide dynamic range of LET(Si) and flux for SPE and GCR, detection of neutrons and biological dose for radiation protection of astronauts. The LURAD design leverages on the following key enabling technologies: (a) Fully depleted Si monolithic active pixel sensors; (b) Scintillators read by silicon photomultipliers (SiPM); (c) Silicon on Insulator (SOI) microdosimetry sensors; These technologies promise miniaturization and mass reduction with state-of-the-art performance. The instrument's design is presented, and the Monte Carlo study of the feasibility of particle identification and kinetic energy determination is discussed

  • Open Access

    Gamma-radiation hardness and long-term stability of ALD-Al2O3 surface passivated Si

    by Michael N. Getz, Marco Povoli, Ozhan Koybasi, Tomas Slavicek, Eduard Monakhov

    Al2O3 has emerged as the surface passivation material of choice for p-type silicon in photovoltaics and has also become a candidate for passivating Si-based radiation sensors. However, the surface passivation of Al2O3 has been shown to degrade when exposed to gamma-radiation, making it of interest to determine methods of depositing Al2O3 that minimize the radiation-induced degradation on the surface passivation. In this study, we investigate the long-term stability and gamma-radiation hardness of Al2O3 prepared using the TMA+H2O+O3 precursor combination and how the pretreatment, the deposition temperature, and the film thickness affect the density of interface states, Dit, and fixed oxide charge, Qfix, before and after gamma-irradiation. We find that the surface saturation current density, J0s, of silicon passivated by Al2O3 increases after annealing but stabilizes over time depending on the Al2O3 thickness. Samples with thicknesses of 60 nm stabilize over days. J0s stabilizes at lower values with increased Al2O3 thickness. After exposure to 1 Mrad gamma-radiation, the samples still exhibit low Dit and high Qfix, with the best performing sample having a Dit of 1.5 × 1010 eV−1 cm−2 and a Qfix of −3.1 × 1012 cm−2. The deposition temperature appears to indirectly affect radiation hardness, owing to its impact on the hydrogen concentration in the film and at the Si–SiOx–Al2O3 interface. Lifetime measurements after irradiation indicate that Al2O3 still passivates the surface effectively. The carrier lifetime and Qfix can largely be recovered by annealing samples in O2 at 435 °C.


  • Charge Collection in SOI Microdosimeters and Their Radiation Hardness

    by V. A. Pan, L. T. Tran, Z. Pastuovic, D. Hill, J. Williams, A. Kok, M. Povoli, A. Pogossov, S. Peracchi, D. Boardman, et al.

    A new batch of microdosimeters has been extensively studied for their charge collection efficiency (CCE) properties, as well as their radiation hardness for medical, space and accident applications. Silicon-on-insulator (SOI) microdosimeters with an active layer thickness of 10, 20 and 50 μm have been investigated and were characterized with a 24 MeV carbon ion beam as well as a Co-60 gamma source. A negative pulse was observed in addition to the positive pulses generated within the sensitive volumes (SVs) by incident ions which led to undesirable low energy events in the SOI microdosimeters response. To study this phenomenon, the microdosimeters were irradiated with gamma radiation from a Co-60 source with a total dose of 3 and 10 Mrad(Si). It was determined that the negative pulse was originating from the support wafer due to the displacement current phenomenon. Irradiation with the Co-60 source led to a disappearing of the negative pulse due to an increase in recombination within the support wafer while almost no changes in CCE were observed. A radiation hardness study was also performed on the 50 μm SOI microdosimeter with 16 SVs being irradiated with a fluence of ~ 10 8 12 C ions/cm 2 . A CCE deficit of approximately 2% was observed at an operation bias of 10V within the SVs. The findings of this work demonstrate that the SOI microdosimeters can be utilized in space and medical applications as they can handle typical levels of dose encountered in these applications. Additionally, evidence for SOI microdosimeter fabrication standards in terms of support wafer resistivity and buried oxide (BOX) thickness is shown.


  • Open Access

    3D silicon detectors for neutron imaging applications

    by M. Povoli, A. Kok, O. Koybasi, M. Getz, G. O’nEill, D. Roehrich, E. Monakhov, H. Pedersen, J. Birch, A.H. Choolakkal, et al.

    Neutron detection is of great importance in many fields spanning from scientific research, to nuclear science, and to medical application. The development of silicon-based neutron detectors with enhanced neutron detection efficiency can offer several advantages such as spatial resolution, enhanced dynamic range and background discrimination. In this work, increased detection efficiency is pursued by fabricating high aspect ratio 3D micro-structures filled with neutron converting materials (B4C) on planar silicon detectors. An in-depth feasibility study was carried out in all aspects of the sensor fabrication technology. Passivation of the etched structures was studied in detail, to ensure good electrical performance. The conformal deposition of B4C with a newly developed process showed excellent results. Preliminary electrical characterisation of the completed devices is promising, and detectors have been mounted on dedicated boards in view of the upcoming tests with neutrons.