Standard Automated Perimetry Before and After Extended Depth-of-Focus Intraocular Lens Implantation: Longitudinal Changes in Global Indices and Test Reliability
Authors:
- Wilson HidaWHWilson Hida
- Maira da SilvaMSMaira da Silva
- Bernardo MoscoviciBMBernardo Moscovici
- César VilarCVCésar Vilar
- Paulo CamposPCPaulo Campos
- Larissa GouveaLGLarissa Gouvea
- Michael ChowMCMichael Chow
- Patrick TzelikisPTPatrick Tzelikis
- Mario Augusto ChavesMCMario Augusto Chaves
- Antonio MottaAMAntonio Motta
- Andre de MedeirosAMAndre de Medeiros
- Jonathan LakeJLJonathan Lake
Open Access
- 1 February 2026
- journal article
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-8
Abstract
To describe changes in standard automated perimetry (SAP) parameters before and after extended depth-of-focus (EDOF) intraocular lens implantation (Symfony) in a longitudinal before–and–after design. Patients undergoing cataract surgery with EDOF IOL implantation were evaluated with SAP preoperatively (baseline) and postoperatively (6–12 months after surgery). Thirteen patients (23 eyes) completed both examinations. The right and left eyes were analyzed separately. Outcomes included foveal threshold, mean deviation (MD), pattern standard deviation (PSD), visual field index (VFI), and reliability indices (false-positive and false-negative rates). Data were summarized as mean ± standard deviation (SD) and compared between time points using paired tests. SAP was performed with the Humphrey Field Analyzer II using the SITA Standard 24–2 strategy. SAP outcomes showed small, non-significant changes from baseline to follow-up. MD improved slightly (right: −1.1 ± 1.2 to −0.8 ± 1.2 dB, p = 0.32; left: −1.9 ± 0.9 to −1.2 ± 1.1 dB, p = 0.12). VFI remained stable (right: 99.1% ± 1.1% to 98.8% ± 1.4%, p = 0.43; left: 98.0% ± 1.1% to 98.0% ± 2.1%, p = 1.00). Foveal threshold was unchanged (right: 35.1 ± 1.9 to 35.2 ± 0.9 dB, p = 0.86; left: 34.0 ± 1.0 to 34.5 ± 1.3 dB, p = 0.26). PSD showed no significant variation (right: 1.9 ± 0.9 to 1.7 ± 0.4 dB, p = 0.34; left: 1.8 ± 0.3 to 1.9 ± 1.2 dB, p = 0.73). Reliability indices were also stable: false positives (right: 1.9% ± 2.6% to 2.1% ± 1.4%, p = 0.75; left: 1.4% ± 2.5% to 0.5% ± 0.6%, p = 0.21) and false negatives (right: 1.6% ± 2.1% to 1.7% ± 3.1%, p = 0.91; left: 2.2% ± 2.9% to 1.1% ± 1.5%, p = 0.35). In this longitudinal before–and–after evaluation, EDOF IOL implantation was not associated with clinically meaningful changes in SAP outcomes, with stable global indices, foveal threshold, and reliability measures.Keywords
This publication has 30 references indexed in Scilit:
- Trifocal versus extended depth of focus (EDOF) intraocular lenses after cataract extractionCochrane Database of Systematic Reviews, 2024
- Peripheral Vision in Patients Following Intraocular Lens Implantation: A Systematic Review and Meta-AnalysisAmerican Journal of Ophthalmology, 2024
- Longitudinal evaluation of trifocal and extended depth of focus lenses implantation using standard automated perimetry parametersInternational Ophthalmology, 2023
- Extended Depth of Focus Versus Trifocal for Intraocular Lens Implantation: An Updated Systematic Review and Meta-AnalysisAmerican Journal of Ophthalmology, 2023
- Visual Outcomes and Optical Quality of Accommodative, Multifocal, Extended Depth-of-Focus, and Monofocal Intraocular Lenses in Presbyopia-Correcting Cataract SurgeryJAMA Ophthalmology, 2022
- Comparative analysis of visual outcomes, reading skills, contrast sensitivity, and patient satisfaction with two models of trifocal diffractive intraocular lenses and an extended range of vision intraocular lensGraefe's Archive for Clinical and Experimental Ophthalmology, 2018
- Influence of Multifocal Intraocular Lenses on Standard Automated Perimetry Test ResultsJAMA Ophthalmology, 2013
- Precision of higher-order aberration measurements with a new Placido-disk topographer and Hartmann-Shack wavefront sensorJournal of Cataract & Refractive Surgery, 2013
- Visual field changes after cataract extraction: The AGIS experienceAmerican Journal of Ophthalmology, 2004
- Test-Retest Variability in Glaucomatous Visual FieldsAmerican Journal of Ophthalmology, 1989