Outcomes and feasibility of redo‐TAVR after Sapien 3 Ultra TAVR in extremely‐undersized versus nominally‐sized annuli
- 21 March 2022
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 99 (6) , 1935-1944
Abstract
Objectives: To compare outcomes in Sapien 3 Ultra (S3U) transcatheter aortic valve replacement (TAVR) with extreme annular undersizing (EAU) versus nominal annular sizing (NAS).Background: The Edwards S3U valve has reduced paravalvular leak (PVL) in TAVR but outcomes remain unknown in extremely undersized anatomy. Implanting a smaller S3U valve may facilitate future redo‐TAVR but risk compromising hemodynamics.Methods: From December 2019 to July 2021, 366 patients with native aortic stenosis underwent S3U TAVR. Patients with EAU (annular areas >430 mm2 for 23 mm or >546 mm2 for 26 mm) were compared to NAS (338–430 mm2 for 23 mm or 430–546 mm2 for 26 mm). In‐hospital and 30‐day outcomes, and redo‐TAVR feasibility were determined.Results: There were 79 (21.6%) EAU patients, with more bicuspid (p = 0.0014) and ≥moderate annular/left ventricular outflow tract calcification (p < 0.001). The EAU group had less annular oversizing than NAS group (23 mm: −8.2 ± 2.6% vs. 4.0 ± 7.0%, p < 0.001; 26 mm: −8.9 ± 2.2% vs. 6.7 ± 6.9%, p < 0.001), more balloon overfilling (71.3% vs. 11.6%, p < 0.001), and postdilatation (15.0% vs. 5.8%, p = 0.016). No differences were found in in‐hospital or 30‐day mortality and stroke (p > 0.05). Mild PVL (13.4% EAU vs. 11.5% NAS, p = 0.56) and mean gradients (23 mm: 13.0 ± 4.5 vs. 14.1 ± 5.4 mmHg, p = 0.40; 26 mm: 11.4 ± 4.1 vs. 11.5 ± 3.9 mmHg, p = 1.0) were similar at 30 days. Had the EAU group undergone NAS with the larger Sapien 3/S3U, by computed tomography analysis simulating 80:20 or 90:10 target implant depth, 33.3%–60.9% (vs. 4.3%–23.2%) would not be feasible for redo‐TAVR due to high risk of coronary obstruction.Conclusions: In this first report of EAU with S3U TAVR, similar excellent short‐term outcomes can be achieved compared to NAS, and may preserve future redo‐TAVR option.Keywords
This publication has 10 references indexed in Scilit:
- Valve Academic Research Consortium 3: Updated Endpoint Definitions for Aortic Valve Clinical ResearchJACC, 2021
- Outcomes 2 Years After Transcatheter Aortic Valve Replacement in Patients at Low Surgical RiskJACC, 2021
- Risk of Coronary Obstruction Due to Sinus Sequestration in Redo Transcatheter Aortic Valve ReplacementJACC: Cardiovascular Interventions, 2020
- Transcatheter Aortic Valve Replacement With Balloon-Expandable ValvesJACC: Cardiovascular Interventions, 2020
- Hemodynamic comparison of transcatheter aortic valve replacement with the SAPIEN 3 Ultra versus SAPIEN 3: The HomoSAPIEN registryCatheterization and Cardiovascular Interventions, 2020
- Mid-Term Outcomes of Transcatheter Aortic Valve Replacement in Extremely Large Annuli With Edwards SAPIEN 3 ValveJACC: Cardiovascular Interventions, 2020
- Feasibility of Repeat TAVR After SAPIEN 3 TAVRJACC: Cardiovascular Interventions, 2019
- Transcatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk PatientsNew England Journal of Medicine, 2019
- Impact of Aortic Root Anatomy and Geometry on Paravalvular Leak in Transcatheter Aortic Valve Replacement With Extremely Large Annuli Using the Edwards SAPIEN 3 ValveJACC: Cardiovascular Interventions, 2018
- Anatomical and Procedural Features Associated With Aortic Root Rupture During Balloon-Expandable Transcatheter Aortic Valve ReplacementCirculation, 2013