Abstract
The paper addresses the issue of optimizing the parallel operation of two identical hydropower aggregates equipped with Crossflow turbines under variable water flow conditions. The objective of the study is to determine the optimal distribution of the plant total flow between the aggregates that maximizes the capacity at a given flow rate. The optimization is formulated using the method of Lagrange multipliers, with the objective function proportional to the hydraulic capacity under constant head conditions. It is shown that when the plant flow does not exceed the nominal flow of one aggregate, the maximum capacity is achieved by operating only one turbine, and no dispatching control is required. In the range of parallel operation of two aggregates, a nontrivial optimization problem arises. Numerical analysis based on manufacturer performance curves of Crossflow turbines demonstrates that the maximum total capacity in this operating zone is achieved when the flow is evenly distributed between the two aggregates. The reduction in efficiency observed for strongly asymmetric flow distributions is explained by the sharp decrease in turbine efficiency at low relative flows, which is characteristic of Crossflow turbines. The obtained results provide a theoretical justification for practical operating rules of small hydropower plants with Crossflow turbines and can be applied in the design and operation of control systems for such facilities.