Intravascular Optical Coherence Tomography for Characterization of Atherosclerosis with a 1.7 Micron Swept-Source Laser
Open Access
- 6 November 2017
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-6
Abstract
The main cause of acute coronary events, such as thrombosis, is the rupture of atherosclerotic plaques. Typical intravascular optical coherence tomography (IVOCT) imaging systems that utilize a 1.3 μm swept source laser are often used for identifying fibrous cap thickness of plaques, yet cannot provide adequate depth penetration to resolve the size of the lipid pool. Here, we present a novel IVOCT system with a 1.7 μm center wavelength swept light source that can readily penetrate deeper into the tissue because of the longer wavelength and allows for better identification of plaques due to the lipid absorption spectrum at 1.7 μm. Using this system, we have imaged a human coronary artery to evaluate the performance of the novel OCT system and verified the results by hematoxylin and eosin (H&E) histology. The significantly improved imaging depth and better identification sensitivity suggest that the 1.7 μm OCT system holds great potential that can be further translated for in-vivo applications of atherosclerosis characterization.Keywords
This publication has 19 references indexed in Scilit:
- Fully integrated optical coherence tomography, ultrasound, and indocyanine green-based fluorescence tri-modality system for intravascular imagingBiomedical Optics Express, 2017
- Anatomically correct visualization of the human upper airway using a high-speed long range optical coherence tomography system with an integrated positioning sensorScientific Reports, 2016
- 3D mapping of elastic modulus using shear wave optical micro-elastographyScientific Reports, 2016
- Validating a bimodal intravascular ultrasound (IVUS) and near-infrared fluorescence (NIRF) catheter for atherosclerotic plaque detection in rabbitsBiomedical Optics Express, 2015
- Imaging and characterizing shear wave and shear modulus under orthogonal acoustic radiation force excitation using OCT Doppler variance methodOptics Letters, 2015
- Integrated intravascular optical coherence tomography ultrasound imaging systemJournal of Biomedical Optics, 2010
- From Vulnerable Plaque to Vulnerable PatientCirculation, 2003
- Quantification of Macrophage Content in Atherosclerotic Plaques by Optical Coherence TomographyCirculation, 2003
- Coronary Plaque DisruptionCirculation, 1995
- Angiographic progression of coronary artery disease and the development of myocardial infarctionJACC, 1988