Joseph C. Jing
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Joseph C. Jing has a total of 76 co-authors. Here are the top co-authors by number of shared publications:
- Zhongping Chen
Beckman Laser Institute, University of California Irvine 1 , Irvine, California 92612
9 shared publications - Qifa Zhou
Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, USA
4 shared publications Jagat Narula
Univ. of California, Irvine Medical Ctr. (United States)
3 shared publicationsJiechen Yin
Univ. of California, Irvine Medical Ctr. (United States)
3 shared publications- Koping Kirk Shung
Department of Biomedical Engineering, University of Southern California, Los Angeles, CA 90089, USA
3 shared publications - Lihong Victory Wang
Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
3 shared publications
Latest Publications
- Open Access
- 1 October 2024
- Published by SPIE-Intl Soc Optical Eng in Biophotonics Discovery
- Vol. 1 (03) , 035002-11
Optical coherence tomography to identify upper airway obstruction sites in an apneic patient
Obstructive sleep apnea (OSA) affects 9% to 38% of the adult population,1 and the corresponding economic impact can be up to $150 billion annually.2 If inadequately diagnosed or treated, OSA can lead to severe health complications such as cardiovascular events, neurocognitive effects, and depression.3 The gold standard diagnostic tool for OSA is polysomnograms, which measure important parameters such as the apnea–hypopnea index, percutaneous oxygen content, rapid eye movement sleep, and limb movements.4 However, polysomnograms cannot provide information regarding the structure and anatomical collapse of the airway. The upper airway is a complex anatomical structure that undergoes dynamic geometric changes over the respiratory cycle. These structural changes can cause airway compromise at many locations, including the palate, base of the tongue, pharyngeal wall, epiglottis, and larynx. The accurate identification of the sites of airway obstruction during sleep is essential for determining the ideal medical or surgical management. Drug-induced sleep endoscopy (DISE)5 is an emerging method to identify the obstruction sites during sleep and is now widely implemented in surgical practice. However, the interpretation of DISE can be subjective with interobserver disagreement in the location of airway obstruction.6 Despite best efforts utilizing multiple diagnostic approaches, a large number of sleep patients (55% to 57%)7 still fail to adequately respond to surgical interventions. As such, the fields of sleep medicine and sleep surgery are in need of better diagnostic tools for the evaluation of upper airway collapse during sleep.
- 1 October 2024
- Published by SPIE-Intl Soc Optical Eng in Biophotonics Discovery
- Vol. 1 (03) , 035002-11
Open AccessOptical coherence tomography to identify upper airway obstruction sites in an apneic patient
Obstructive sleep apnea (OSA) affects 9% to 38% of the adult population,1 and the corresponding economic impact can be up to $150 billion annually.2 If inadequately diagnosed or treated, OSA can lead to severe health complications such as cardiovascular events, neurocognitive effects, and depression.3 The gold standard diagnostic tool for OSA is polysomnograms, which measure important parameters such as the apnea–hypopnea index, percutaneous oxygen content, rapid eye movement sleep, and limb movements.4 However, polysomnograms cannot provide information regarding the structure and anatomical collapse of the airway. The upper airway is a complex anatomical structure that undergoes dynamic geometric changes over the respiratory cycle. These structural changes can cause airway compromise at many locations, including the palate, base of the tongue, pharyngeal wall, epiglottis, and larynx. The accurate identification of the sites of airway obstruction during sleep is essential for determining the ideal medical or surgical management. Drug-induced sleep endoscopy (DISE)5 is an emerging method to identify the obstruction sites during sleep and is now widely implemented in surgical practice. However, the interpretation of DISE can be subjective with interobserver disagreement in the location of airway obstruction.6 Despite best efforts utilizing multiple diagnostic approaches, a large number of sleep patients (55% to 57%)7 still fail to adequately respond to surgical interventions. As such, the fields of sleep medicine and sleep surgery are in need of better diagnostic tools for the evaluation of upper airway collapse during sleep.
- Open Access
- 6 September 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-12
Ultrafast and hypersensitive phase imaging of propagating internodal current flows in myelinated axons and electromagnetic pulses in dielectrics
Many ultrafast phenomena in biology and physics are fundamental to our scientific understanding but have not yet been visualized owing to the extreme speed and sensitivity requirements in imaging modalities. Two examples are the propagation of passive current flows through myelinated axons and electromagnetic pulses through dielectrics, which are both key to information processing in living organisms and electronic devices. Here, we demonstrate differentially enhanced compressed ultrafast photography (Diff-CUP) to directly visualize propagations of passive current flows at approximately 100 m/s along internodes, i.e., continuous myelinated axons between nodes of Ranvier, from Xenopus laevis sciatic nerves and of electromagnetic pulses at approximately 5 × 107 m/s through lithium niobate. The spatiotemporal dynamics of both propagation processes are consistent with the results from computational models, demonstrating that Diff-CUP can span these two extreme timescales while maintaining high phase sensitivity. With its ultrahigh speed (picosecond resolution), high sensitivity, and noninvasiveness, Diff-CUP provides a powerful tool for investigating ultrafast biological and physical phenomena.
- 6 September 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-12
Open AccessUltrafast and hypersensitive phase imaging of propagating internodal current flows in myelinated axons and electromagnetic pulses in dielectrics
Many ultrafast phenomena in biology and physics are fundamental to our scientific understanding but have not yet been visualized owing to the extreme speed and sensitivity requirements in imaging modalities. Two examples are the propagation of passive current flows through myelinated axons and electromagnetic pulses through dielectrics, which are both key to information processing in living organisms and electronic devices. Here, we demonstrate differentially enhanced compressed ultrafast photography (Diff-CUP) to directly visualize propagations of passive current flows at approximately 100 m/s along internodes, i.e., continuous myelinated axons between nodes of Ranvier, from Xenopus laevis sciatic nerves and of electromagnetic pulses at approximately 5 × 107 m/s through lithium niobate. The spatiotemporal dynamics of both propagation processes are consistent with the results from computational models, demonstrating that Diff-CUP can span these two extreme timescales while maintaining high phase sensitivity. With its ultrahigh speed (picosecond resolution), high sensitivity, and noninvasiveness, Diff-CUP provides a powerful tool for investigating ultrafast biological and physical phenomena.
- Open Access
- 28 April 2020
- Published by Springer Nature in Nature Communications
- Vol. 11 (1) , 1-9
Spatio-temporal-spectral imaging of non-repeatable dissipative soliton dynamics
Dissipative solitons (DSs) are multi-dimensionally localized waves that arise from complex dynamical balances in far-from-equilibrium nonlinear systems and widely exist in physics, chemistry and biology. Real-time observations of DS dynamics across many dimensions thus have a broad impact on unveiling various nonlinear complexities in different fields. However, these observations are challenging as DS transitions are stochastic, non-repeatable and often strongly coupled across spatio-temporal-spectral (STS) domains. Here we report multi-dimensional (space xy + discrete time t + wavelength λ) DS dynamics imaged by STS compressed ultrafast photography, enabling imaging at up to trillions of frames per second. Various transient and random phenomena of multimode DSs are revealed, highlighting the importance of real-time multi-dimensional observation without the need for event repetition in decomposing the complexities of DSs.
- 28 April 2020
- Published by Springer Nature in Nature Communications
- Vol. 11 (1) , 1-9
Open AccessSpatio-temporal-spectral imaging of non-repeatable dissipative soliton dynamics
Dissipative solitons (DSs) are multi-dimensionally localized waves that arise from complex dynamical balances in far-from-equilibrium nonlinear systems and widely exist in physics, chemistry and biology. Real-time observations of DS dynamics across many dimensions thus have a broad impact on unveiling various nonlinear complexities in different fields. However, these observations are challenging as DS transitions are stochastic, non-repeatable and often strongly coupled across spatio-temporal-spectral (STS) domains. Here we report multi-dimensional (space xy + discrete time t + wavelength λ) DS dynamics imaged by STS compressed ultrafast photography, enabling imaging at up to trillions of frames per second. Various transient and random phenomena of multimode DSs are revealed, highlighting the importance of real-time multi-dimensional observation without the need for event repetition in decomposing the complexities of DSs.
- Open Access
- 21 February 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 6 (8) , eaay1192
Real-time frequency-encoded spatiotemporal focusing through scattering media using a programmable 2D ultrafine optical frequency comb
A frequency-encoded spatiotemporal focusing technology enables real-time optical wavefront shaping through thick scattering media.
- 21 February 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 6 (8) , eaay1192
Open AccessReal-time frequency-encoded spatiotemporal focusing through scattering media using a programmable 2D ultrafine optical frequency comb
A frequency-encoded spatiotemporal focusing technology enables real-time optical wavefront shaping through thick scattering media.
- Open Access
- 13 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 25 (1) , 1-5
High-Speed Integrated Endoscopic Photoacoustic and Ultrasound Imaging System
Endoscopic integrated photoacoustic and ultrasound imaging has the potential for early detection of cancer in the gastrointestinal tract. Currently, a slow imaging speed is one of the limitations for clinical translation. Here, we developed a high-speed integrated endoscopic PA and US imaging system, which is able to perform PA and US imaging simultaneously up to 50 frames per second. Using this system, the architectural morphology and vasculature of the rectum wall were visualized from a Sprague Dawley rat in vivo.
- 13 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 25 (1) , 1-5
Open AccessHigh-Speed Integrated Endoscopic Photoacoustic and Ultrasound Imaging System
Endoscopic integrated photoacoustic and ultrasound imaging has the potential for early detection of cancer in the gastrointestinal tract. Currently, a slow imaging speed is one of the limitations for clinical translation. Here, we developed a high-speed integrated endoscopic PA and US imaging system, which is able to perform PA and US imaging simultaneously up to 50 frames per second. Using this system, the architectural morphology and vasculature of the rectum wall were visualized from a Sprague Dawley rat in vivo.
- Open Access
- 7 June 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 8713
Automated 3D segmentation of methyl isocyanate-exposed rat trachea using an ultra-thin, fully fiber optic optical coherence endoscopic probe
Development of effective rescue countermeasures for toxic inhalational industrial chemicals, such as methyl isocyanate (MIC), has been an emerging interest. Nonetheless, current methods for studying toxin-induced airway injuries are limited by cost, labor time, or accuracy, and only provide indirect or localized information. Optical Coherence Tomography (OCT) endoscopic probes have previously been used to visualize the 3-D airway structure. However, gathering such information in small animal models, such as rat airways after toxic gas exposure, remains a challenge due to the required probe size necessary for accessing the small, narrow, and partially obstructed tracheas. In this study, we have designed a 0.4 mm miniature endoscopic probe and investigated the structural changes in rat trachea after MIC inhalation. An automated 3D segmentation algorithm was implemented so that anatomical changes, such as tracheal lumen volume and cross-sectional areas, could be quantified. The tracheal region of rats exposed to MIC by inhalation showed significant airway narrowing, especially within the upper trachea, as a result of epithelial detachment and extravascular coagulation within the airway. This imaging and automated reconstruction technique is capable of rapid and minimally-invasive identification of airway obstruction. This method can be applied to large-scale quantitative analysis of in vivo animal models.
- 7 June 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 8713
Open AccessAutomated 3D segmentation of methyl isocyanate-exposed rat trachea using an ultra-thin, fully fiber optic optical coherence endoscopic probe
Development of effective rescue countermeasures for toxic inhalational industrial chemicals, such as methyl isocyanate (MIC), has been an emerging interest. Nonetheless, current methods for studying toxin-induced airway injuries are limited by cost, labor time, or accuracy, and only provide indirect or localized information. Optical Coherence Tomography (OCT) endoscopic probes have previously been used to visualize the 3-D airway structure. However, gathering such information in small animal models, such as rat airways after toxic gas exposure, remains a challenge due to the required probe size necessary for accessing the small, narrow, and partially obstructed tracheas. In this study, we have designed a 0.4 mm miniature endoscopic probe and investigated the structural changes in rat trachea after MIC inhalation. An automated 3D segmentation algorithm was implemented so that anatomical changes, such as tracheal lumen volume and cross-sectional areas, could be quantified. The tracheal region of rats exposed to MIC by inhalation showed significant airway narrowing, especially within the upper trachea, as a result of epithelial detachment and extravascular coagulation within the airway. This imaging and automated reconstruction technique is capable of rapid and minimally-invasive identification of airway obstruction. This method can be applied to large-scale quantitative analysis of in vivo animal models.
- Open Access
- 6 November 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-6
Intravascular Optical Coherence Tomography for Characterization of Atherosclerosis with a 1.7 Micron Swept-Source Laser
The main cause of acute coronary events, such as thrombosis, is the rupture of atherosclerotic plaques. Typical intravascular optical coherence tomography (IVOCT) imaging systems that utilize a 1.3 μm swept source laser are often used for identifying fibrous cap thickness of plaques, yet cannot provide adequate depth penetration to resolve the size of the lipid pool. Here, we present a novel IVOCT system with a 1.7 μm center wavelength swept light source that can readily penetrate deeper into the tissue because of the longer wavelength and allows for better identification of plaques due to the lipid absorption spectrum at 1.7 μm. Using this system, we have imaged a human coronary artery to evaluate the performance of the novel OCT system and verified the results by hematoxylin and eosin (H&E) histology. The significantly improved imaging depth and better identification sensitivity suggest that the 1.7 μm OCT system holds great potential that can be further translated for in-vivo applications of atherosclerosis characterization.
- 6 November 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-6
Open AccessIntravascular Optical Coherence Tomography for Characterization of Atherosclerosis with a 1.7 Micron Swept-Source Laser
The main cause of acute coronary events, such as thrombosis, is the rupture of atherosclerotic plaques. Typical intravascular optical coherence tomography (IVOCT) imaging systems that utilize a 1.3 μm swept source laser are often used for identifying fibrous cap thickness of plaques, yet cannot provide adequate depth penetration to resolve the size of the lipid pool. Here, we present a novel IVOCT system with a 1.7 μm center wavelength swept light source that can readily penetrate deeper into the tissue because of the longer wavelength and allows for better identification of plaques due to the lipid absorption spectrum at 1.7 μm. Using this system, we have imaged a human coronary artery to evaluate the performance of the novel OCT system and verified the results by hematoxylin and eosin (H&E) histology. The significantly improved imaging depth and better identification sensitivity suggest that the 1.7 μm OCT system holds great potential that can be further translated for in-vivo applications of atherosclerosis characterization.
- Open Access
- 17 August 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-11
Visualization and Detection of Ciliary Beating Pattern and Frequency in the Upper Airway using Phase Resolved Doppler Optical Coherence Tomography
Ciliary motion plays a critical role in the overall respiratory health of the upper airway. These cilia beat at a native frequency and in a synchronized pattern to continuously transport foreign particulate trapped in a layer of mucous out of the upper airway. Disruption of ciliary motion can lead to severe respiratory diseases and compromised respiratory function. Currently, the study of cilia requires expensive high speed cameras and high powered microscopes which is unsuitable for in vivo imaging and diagnosis. Doppler based optical coherence tomography has the potential to visualize the microscopic motion of cilia during their beating cycle. We demonstrate the development of a high-speed Doppler optical coherence tomography system that not only can rapidly determine the cilia beat frequency, but also simultaneously visualize the temporal cilia beating pattern which plays critical roles in cilia function.
- 17 August 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-11
Open AccessVisualization and Detection of Ciliary Beating Pattern and Frequency in the Upper Airway using Phase Resolved Doppler Optical Coherence Tomography
Ciliary motion plays a critical role in the overall respiratory health of the upper airway. These cilia beat at a native frequency and in a synchronized pattern to continuously transport foreign particulate trapped in a layer of mucous out of the upper airway. Disruption of ciliary motion can lead to severe respiratory diseases and compromised respiratory function. Currently, the study of cilia requires expensive high speed cameras and high powered microscopes which is unsuitable for in vivo imaging and diagnosis. Doppler based optical coherence tomography has the potential to visualize the microscopic motion of cilia during their beating cycle. We demonstrate the development of a high-speed Doppler optical coherence tomography system that not only can rapidly determine the cilia beat frequency, but also simultaneously visualize the temporal cilia beating pattern which plays critical roles in cilia function.
- 1 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 20 (2) , 196-203
Integrated IVUS-OCT Imaging for Atherosclerotic Plaque Characterization
For the diagnosis of atherosclerosis, biomedical imaging techniques such as intravascular ultrasound (IVUS) and optical coherence tomography (OCT) have been developed. The combined use of IVUS and OCT is hypothesized to remarkably increase diagnostic accuracy of vulnerable plaques. We have developed an integrated IVUS-OCT imaging apparatus, which includes the integrated catheter, motor drive unit, and imaging system. The dual-function imaging catheter has the same diameter of current clinical standard. The imaging system is capable for simultaneous IVUS and OCT imaging in real time. Ex vivo and in vivo experiments on rabbits with atherosclerosis were conducted to demonstrate the feasibility and superiority of the integrated intravascular imaging modality.
- 1 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 20 (2) , 196-203
Integrated IVUS-OCT Imaging for Atherosclerotic Plaque Characterization
For the diagnosis of atherosclerosis, biomedical imaging techniques such as intravascular ultrasound (IVUS) and optical coherence tomography (OCT) have been developed. The combined use of IVUS and OCT is hypothesized to remarkably increase diagnostic accuracy of vulnerable plaques. We have developed an integrated IVUS-OCT imaging apparatus, which includes the integrated catheter, motor drive unit, and imaging system. The dual-function imaging catheter has the same diameter of current clinical standard. The imaging system is capable for simultaneous IVUS and OCT imaging in real time. Ex vivo and in vivo experiments on rabbits with atherosclerosis were conducted to demonstrate the feasibility and superiority of the integrated intravascular imaging modality.