The Real Issue with Wall Deposits in Closed Filter Cassettes—What's the Sample?
Authors:
- Michael J. BrissonMBMichael J. Brisson
- Melecita M. ArchuletaMAMelecita M. Archuleta
- 30 October 2009
- journal article
- review article
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 6 (12) , 783-788
Abstract
The measurement of aerosol dusts has long been utilized to assess the exposure of workers to metals. Tools used to sample and measure aerosol dusts have gone through many transitions over the past century. In particular, there have been several different techniques used to sample for beryllium, not all of which might be expected to produce the same result. Today, beryllium samples are generally collected using filters housed in holders of several different designs, some of which are expected to produce a sample that mimics the human capacity for dust inhalation. The presence of dust on the interior walls of cassettes used to hold filters during metals sampling has been discussed in the literature for a number of metals, including beryllium, with widely varying data. It appears that even in the best designs, particulates can enter the sampling cassette and deposit on the interior walls rather than on the sampling medium. The causes are not well understood but are believed to include particle bounce, electrostatic forces, particle size, particle density, and airflow turbulence. Historically, the filter catch has been considered to be the sample, but the presence of wall deposits, and the potential that the filter catch is not representative of the exposure to the worker, puts that historical position into question. This leads to a fundamental question: What is the sample? This article reviews the background behind the issue, poses the above-mentioned question, and discusses options and a possible path forward for addressing that question.Keywords
This publication has 25 references indexed in Scilit:
- A review of workplace aerosol sampling procedures and their relevance to the assessment of beryllium exposuresJournal of Environmental Monitoring, 2006
- Opportunities for Standardization of Beryllium Sampling and Analysis2006
- Design and Performance of a New Personal Aerosol MonitorAerosol Science and Technology, 1999
- Aerosol Instrumentation in Occupational Hygiene: An Historical PerspectiveAerosol Science and Technology, 1998
- Investigation into the impact of introducing workplace aerosol standards based on the inhalable fractionThe Analyst, 1996
- New aerosol sampler with low wind sensitivity and good filter collection uniformityAtmospheric Environment, 1995
- INTERNAL WALL LOSSES OF PHARMACEUTICAL DUCTS DURING CLOSED-FACE, 37-MM POLYSTYRENE CASSETTE SAMPLINGAIHA Journal, 1991
- AEROSOL EVALUATION DIFFICULTIES DUE TO PARTICLE DEPOSITION ON FILTER HOLDER INNER WALLSAnnals of Occupational Hygiene, 1990
- Sampling errors in blunt dust samplers arising from external wall loss effectsAtmospheric Environment (1967), 1981
- A comparison of aerosol sampling techniques: “open” versus “closed-face” filter cassettesAIHA Journal, 1980