Imaging assessment of bioresorbable vascular scaffolds
- 1 August 2017
- journal article
- review article
- Published by Springer Nature in Cardiovascular Intervention and Therapeutics
- Vol. 33 (1) , 11-22
Abstract
Vascular reparative therapy has become a reality with bioresorbable scaffolds (BRSs). To assess acute and long-term performance of the device, multimodality imaging would be essential. Radiopacity of metal hinders the imaging assessment, whereas radiolucent polymeric scaffolds allow for a precise imaging assessment with either invasive or non-invasive modality at baseline and at follow-up, which is one of the advantages of polymeric BRSs. Recent large trials evaluating clinical results of the first-generation BRS technology raised concerns about the safety and efficacy of these devices, namely, scaffold thrombosis. Intensive research with multimodality imaging in the field is being conducted to have in-depth understanding of the issues, which will facilitate the improvement of implantation techniques and the development of the next-generation BRSs. The current review focuses on the clinical application of the imaging modalities to assess the short- and long-term performance of the Absorb BVS.Keywords
This publication has 62 references indexed in Scilit:
- Automated tissue characterization of in vivo atherosclerotic plaques by intravascular optical coherence tomography imagesBiomedical Optics Express, 2013
- Role of Endothelial Shear Stress in Stent Restenosis and ThrombosisJACC, 2012
- From metallic cages to transient bioresorbable scaffolds: change in paradigm of coronary revascularization in the upcoming decade?European Heart Journal, 2011
- Temporal changes of coronary artery plaque located behind the struts of the everolimus eluting bioresorbable vascular scaffoldThe International Journal of Cardiovascular Imaging, 2010
- Atherosclerotic tissue characterization in vivo by optical coherence tomography attenuation imagingJournal of Biomedical Optics, 2010
- Hemodynamically Driven Stent Strut DesignAnnals of Biomedical Engineering, 2009
- Evaluation of the effect of stent strut profile on shear stress distribution using statistical momentsBioMedical Engineering OnLine, 2009
- Assessment of the absorption process following bioabsorbable everolimus-eluting stent implantation: temporal changes in strain values and tissue composition using intravascular ultrasound radiofrequency data analysis A substudy of the ABSORB clinical trialEuroIntervention, 2009
- Vascular bed origin dictates flow pattern regulation of endothelial adhesion molecule expressionAmerican Journal of Physiology-Heart and Circulatory Physiology, 2007
- Characterizing Vulnerable Plaque Features With Intravascular ElastographyCirculation, 2003