A flexible electrochemical glucose sensing platform based on an electrospun PVA mat covered with in situ grown silver nanoparticles and a mixed self-assembled monolayer of glucose oxidase and ferrocene
- 26 June 2023
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 148 (16) , 3724-3729
Abstract
Electrochemical glucose sensor based on flexible materials is significant for wearable devices used for real-time health monitoring and diagnosis. However, applying flexible electrodes involves complex fabrication processes and might reduce detection sensitivity. To overcome these obstacles, we herein reported a novel strategy for preparing a highly flexible enzyme electrode based on electrospun poly(vinyl alcohol) (PVA) mat decorated by in-situ grown silver nanoparticles (nano-Ag) for electrochemical glucose sensing. Ferrocene (Fc) was selected as an electron acceptor for glucose oxidase (GOD) in order to minimize the influence of oxygen. Electron transfer between GOD and Fc was facilitated by confining them within a mixed self-assembled monolayer (SAM) formed on the thin layer of gold deposited on top of the PVA/nano-Ag film. Nano-Ag was found to significantly increase the surface area of the electrode and improve the stability of electrode conductivity during tensile deformation. Electrochemical glucose detection was performed by chronoamperometry in the electroactivity domain of ferrocene, and good linearity (R2=0.993) was obtained in the range of 0.2-7 mM with a detection limit of 0.038 mM and a relative standard deviation (RSD) of 1.45% (n=6). After being stuck to a bendable PDMS slice and bent, respectively, at 30° and 60° for 50 times, the electrode showed slight changes in detection results (<4.78%), which remained within 8% when the bending angle increased to 90°. With its high flexibility, good detection performance, and convenient fabrication process, the proposed enzyme electrode showed good potential as a flexible platform for wearable glucose sensing systems.Keywords
Funding Information
- Zhengzhou Tobacco Research Institute, China National Tobacco Corporation
- National Natural Science Foundation of China (32130083)
This publication has 41 references indexed in Scilit:
- Evaluation of a Minimally Invasive System for Measuring Glucose Area under the Curve during Oral Glucose Tolerance Tests: Usefulness of Sweat Monitoring for Precise MeasurementJournal of Diabetes Science and Technology, 2013
- Label-free and reagentless electrochemical detection of PCR fragments using self-assembled quinone derivative monolayer: Application to Mycobacterium tuberculosisBiosensors and Bioelectronics, 2012
- Glucose Biosensor Using Glucose Oxidase and Electrospun Mn2O3‐Ag NanofibersElectroanalysis, 2011
- Effect of Mediator Spacing on Electrochemical and Enzymatic Response of Ferrocene Redox PolymersThe Journal of Physical Chemistry C, 2010
- Nanometric Layers for Direct, Signal-On, Selective, and Sensitive Electrochemical Detection of Oligonucleotides HybridizationJournal of the American Chemical Society, 2008
- Electrochemically polymerised composites of multi-walled carbon nanotubes and poly(vinylferrocene) and their use as modified electrodes: Application to glucose sensingThe Analyst, 2006
- Development of a Carbon Film Electrode Ferrocene‐Mediated Glucose BiosensorAnalytical Letters, 2005
- Self-Assembled Monolayers of Thiolates on Metals as a Form of NanotechnologyChemical Reviews, 2005
- Layer-by-Layer Self-Assembly of Glucose Oxidase with a Poly(allylamine)ferrocene Redox MediatorLangmuir, 1997
- Glucose Oxidase as an Analytical ReagentCritical Reviews in Analytical Chemistry, 1995