Optimizing variable flip angles in magnetization‐prepared gradient‐echo sequences for efficient 3D‐T1ρ mapping
- 8 June 2023
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (4) , 1465-1483
Abstract
Purpose: To optimize the choice of the flip angles of magnetization‐prepared gradient‐echo sequences for improved accuracy, precision, and speed of 3D‐T1ρ mapping.Methods: We propose a new optimization approach for finding variable flip‐angle values that improve magnetization‐prepared gradient‐echo sequences used for 3D‐T1ρ mapping. This new approach can improve the accuracy and SNR, while reducing filtering effects. We demonstrate the concept in the three different versions of the magnetization‐prepared gradient‐echo sequences that are typically used for 3D‐T1ρ mapping and evaluate their performance in model agarose phantoms (n = 4) and healthy volunteers (n = 5) for knee joint imaging. We also tested the optimization with sequence parameters targeting faster acquisitions.Results: Our results show that optimized variable flip angle can improve the accuracy and the precision of the sequences, seen as a reduction of the mean of normalized absolute difference from about 5%–6% to 3%–4% in model phantoms and from 15%–16% to 11%–13% in the knee joint, and improving SNR from about 12–28 to 22–32 in agarose phantoms and about 7–14 to 13–17 in healthy volunteers. The optimization can also compensate for the loss in quality caused by making the sequence faster. This results in sequence configurations that acquire more data per unit of time with SNR and mean of normalized absolute difference measurements close to its slower versions.Conclusion: The optimization of the variable flip angle can be used to increase accuracy and precision, and to improve the speed of the typical imaging sequences used for quantitative 3D‐T1ρ mapping of the knee joint.Keywords
All Related Versions
Funding Information
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (R01‐AR076328‐01A1, R01‐AR076985‐01A1, R01‐AR078308‐01A1, R21‐AR075259‐01A1)
- National Institute of Biomedical Imaging and Bioengineering (P41‐EB017183)
- Center for Advanced Imaging Innovation and Research
This publication has 46 references indexed in Scilit:
- Ultrafast imaging: Principles, pitfalls, solutions, and applicationsJournal of Magnetic Resonance Imaging, 2010
- T1ρ‐prepared balanced gradient echo for rapid 3D T1ρ MRIJournal of Magnetic Resonance Imaging, 2008
- In vivo T1ρ mapping in cartilage using 3D magnetization‐prepared angle‐modulated partitioned k‐space spoiled gradient echo snapshots (3D MAPSS)Magnetic Resonance in Medicine, 2008
- 3D magnetization prepared elliptical centric fast gradient echo imagingMagnetic Resonance in Medicine, 2008
- Sparse MRI: The application of compressed sensing for rapid MR imagingMagnetic Resonance in Medicine, 2007
- MP‐SAGE: A new MP‐RAGE sequence with enhanced SNR and CNR for brain imaging utilizing square‐spiral phase encoding and variable flip anglesMagnetic Resonance in Medicine, 2006
- Encoding and reconstruction in parallel MRINMR in Biomedicine, 2006
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Phase‐Modulated binomial RF pulses for fast spectrally‐selective musculoskeletal imagingMagnetic Resonance in Medicine, 1996
- Three‐dimensional magnetization‐prepared rapid gradient‐echo imaging (3D MP RAGE)Magnetic Resonance in Medicine, 1990