Measurement of Voltage distribution and Partial Discharge Position in Inverter-fed Rectangular Wire Motor
- 12 December 2021
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 570-573
Abstract
In inverter-fed motors, enough insulation film thickness is required to prevent partial discharge in the air gap between coils caused by high voltage. In this paper, for better insulation design of a motor, the behavior of surge voltage in the motor and position of partial discharge caused by surge voltage is discussed. The partial discharge occurrence position is evaluated by detection of the electromagnetic wave using multiple antennas when the voltage is applied to single phase coils of the motor. The comparison of voltage distribution and partial discharge point indicates the surge voltage waveform between coils due to resonance differs intricately for each coil. Moreover, partial discharge occurs in the part where the voltage value between coils is large.Keywords
This publication has 4 references indexed in Scilit:
- Analysis on Surge Voltage in Inverter-fed Motor Using Frequency Response Analysis2019
- Influence of Electromagnetic Sensor Location on Repetitive Partial Discharge Inception Voltage in Actual Stator Core of Inverter Fed Motor2018
- Propagation of inverter surge and voltage distribution in motor windingElectrical Engineering in Japan, 2007
- Surge propagation and overvoltages for PWM-inverter-driven motorsElectrical Engineering in Japan, 2000