Tomohiro Yamada
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tomohiro Yamada has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Kengo Takagi
SOKEN INC.,Japan
1 shared publication - Miho Fujieda
National Institute of Information and Communications Technology, Tokyo, Japan
1 shared publication - Tatsuhiko Yamada
Center for Advanced Materials, Forestry and Forest Products Research Institute (FFPRI), 1 Matsunosato, Tsukuba 305-8687, Japan
1 shared publication - Thi Thi Nge
Center for Advanced Materials, Forestry and Forest Products Research Institute (FFPRI), 1 Matsunosato, Tsukuba 305-8687, Japan
1 shared publication - Yasuhiko Hayashi
Graduate School of Natural Science and Technology, Okayama University, Okayama, Japan
1 shared publication - Yoshimitsu Takahashi
Department of Implementation Science in Public Health, Kyoto University School of Public Health, Kyoto, Japan
1 shared publication
Latest Publications
- Open Access
- 10 June 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (25) , 27610-27617
Acid-Catalyzed Solvolysis of Softwood in Caprylyl Glycol to Produce Lignin Derivatives
Glycol lignin (GL) is produced via the acid-catalyzed solvolysis of softwood meal using glycols such as polyethylene glycol. The physicochemical and thermal properties of GL are expected to be controllable by varying the glycol type. In this study, caprylyl glycol (CG), which is a biobased glycol derived from the caprylic acid component of coconut and palm oils, was used to investigate the effects on the acid-catalyzed solvolysis of softwood. The reactions were performed at 140, 150, and 160 °C for 30–120 min to obtain lignin derivatives (CG-lignin: CGL). The chemical and physical properties of CGLs were investigated. Two-dimensional heteronuclear single-quantum coherence nuclear magnetic resonance analysis suggested that CGL possesses an α-CG-β-O-4 structure as CG is grafted onto the lignin structure. CGLs prepared at higher reaction temperatures exhibited lower molecular weights. The thermomechanical analysis of CGL revealed a glass transition temperature of 89–96 °C and a viscous thermal flow temperature of 134–155 °C.
- 10 June 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (25) , 27610-27617
Open AccessAcid-Catalyzed Solvolysis of Softwood in Caprylyl Glycol to Produce Lignin Derivatives
Glycol lignin (GL) is produced via the acid-catalyzed solvolysis of softwood meal using glycols such as polyethylene glycol. The physicochemical and thermal properties of GL are expected to be controllable by varying the glycol type. In this study, caprylyl glycol (CG), which is a biobased glycol derived from the caprylic acid component of coconut and palm oils, was used to investigate the effects on the acid-catalyzed solvolysis of softwood. The reactions were performed at 140, 150, and 160 °C for 30–120 min to obtain lignin derivatives (CG-lignin: CGL). The chemical and physical properties of CGLs were investigated. Two-dimensional heteronuclear single-quantum coherence nuclear magnetic resonance analysis suggested that CGL possesses an α-CG-β-O-4 structure as CG is grafted onto the lignin structure. CGLs prepared at higher reaction temperatures exhibited lower molecular weights. The thermomechanical analysis of CGL revealed a glass transition temperature of 89–96 °C and a viscous thermal flow temperature of 134–155 °C.
- 12 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 570-573
Measurement of Voltage distribution and Partial Discharge Position in Inverter-fed Rectangular Wire Motor
In inverter-fed motors, enough insulation film thickness is required to prevent partial discharge in the air gap between coils caused by high voltage. In this paper, for better insulation design of a motor, the behavior of surge voltage in the motor and position of partial discharge caused by surge voltage is discussed. The partial discharge occurrence position is evaluated by detection of the electromagnetic wave using multiple antennas when the voltage is applied to single phase coils of the motor. The comparison of voltage distribution and partial discharge point indicates the surge voltage waveform between coils due to resonance differs intricately for each coil. Moreover, partial discharge occurs in the part where the voltage value between coils is large.
- 12 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 570-573
Measurement of Voltage distribution and Partial Discharge Position in Inverter-fed Rectangular Wire Motor
In inverter-fed motors, enough insulation film thickness is required to prevent partial discharge in the air gap between coils caused by high voltage. In this paper, for better insulation design of a motor, the behavior of surge voltage in the motor and position of partial discharge caused by surge voltage is discussed. The partial discharge occurrence position is evaluated by detection of the electromagnetic wave using multiple antennas when the voltage is applied to single phase coils of the motor. The comparison of voltage distribution and partial discharge point indicates the surge voltage waveform between coils due to resonance differs intricately for each coil. Moreover, partial discharge occurs in the part where the voltage value between coils is large.