Deep learning for temporal super-resolution 4D Flow MRI
Open Access
- 25 March 2026
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. PP (02780062) , 1
Abstract
4D Flow Magnetic Resonance Imaging (4D Flow MRI) is a non-invasive technique for volumetric, time-resolved blood flow quantification. However, apparent trade-offs between acquisition time, image noise, and resolution limit clinical applicability. In particular, in regions of highly transient flow, coarse temporal resolution can hinder accurate capture of physiologically relevant flow variations. Deep learning-based post-processing techniques have shown promise in overcoming these issues using so-called super-resolution networks. However, while existing super-resolution research has primarily focused on spatial upsampling, temporal super-resolution remains largely unexplored. The aim of this study was therefore to implement and evaluate a residual data-driven network for temporal super-resolution 4D Flow MRI. To achieve this, an existing spatial network (4DFlowNet) was re-designed for temporal upsampling, adapting input dimensions, and optimizing internal layer structures. The model was trained and tested on synthetic 4D Flow MRI data derived from patient-specific in-silico models, followed by additional evaluation on clinically acquired in-vivo datasets. Overall, excellent performance was achieved with input velocities effectively denoised and temporally upsampled, with a mean absolute error (MAE) of 1.0 cm/s in an unseen in-silico setting, outperforming deterministic alternatives (linear interpolation MAE = 2.3 cm/s, sinc interpolation MAE = 2.6 cm/s). Further, the network synthesized high-resolution temporal information from unseen low-resolution in-vivo data, with strong correlation observed at peak flow frames. As such, our results highlight the potential of utilizing data-driven neural networks for temporal super-resolution 4D Flow MRI, enabling high-frame-rate flow quantification without extending acquisition times beyond clinically acceptable limits.Keywords
All Related Versions
Funding Information
- European Research Council (101075494)
This publication has 48 references indexed in Scilit:
- Blood flow imaging by optimal matching of computational fluid dynamics to 4D‐flow dataMagnetic Resonance in Medicine, 2020
- Sector‐wise golden‐angle phase contrast with high temporal resolution for evaluation of left ventricular diastolic dysfunctionMagnetic Resonance in Medicine, 2019
- Assessment of Reynolds stress components and turbulent pressure loss using 4D flow MRI with extended motion encodingMagnetic Resonance in Medicine, 2017
- Variability of 4D flow parameters when subjected to changes in MRI acquisition parameters using a realistic thoracic aortic phantomMagnetic Resonance in Medicine, 2017
- Efficient method for volumetric assessment of peak blood flow velocity using 4D flow MRIJournal of Magnetic Resonance Imaging, 2016
- Reproducibility and interobserver variability of systolic blood flow velocity and 3D wall shear stress derived from 4D flow MRI in the healthy aortaJournal of Magnetic Resonance Imaging, 2015
- Congenital heart disease assessment with 4D flow MRIJournal of Magnetic Resonance Imaging, 2015
- Reproducibility study of four‐dimensional flow MRI of arterial and portal venous liver hemodynamics: Influence of spatio‐temporal resolutionMagnetic Resonance in Medicine, 2013
- 4D flow MRIJournal of Magnetic Resonance Imaging, 2012
- Sparse MRI: The application of compressed sensing for rapid MR imagingMagnetic Resonance in Medicine, 2007