Influence of opacifiers on dimensional stability and detail reproduction of maxillofacial silicone elastomer
Open Access
- 1 January 2010
- journal article
- research article
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 9 (1) , 85
Abstract
We evaluated the influence of chemical disinfection and accelerated aging on the dimensional stability and detail reproduction of a silicone elastomer containing one of two opacifiers. A total of 90 samples were fabricated from Silastic MDX 4-4210 silicone and divided into groups (n = 10) according to opacifier content (barium sulfate or titanium dioxide) and disinfectant solution (neutral soap, Efferdent, or 4% chlorhexidine). The specimens were disinfected 3 times per week during 60 days and then subjected to accelerated aging for 1008 hours. Dimensional stability and detail reproduction tests were performed after specimens' fabrication (baseline), chemical disinfection and periodically during accelerated aging (252, 504, and 1008 hours). The results were analyzed using 3-way repeated-measures ANOVA and the Tukey HSD test (α = 0.05). All groups exhibited dimensional changes over time. The opacifier (p = .314), period (p < .0001) and their interactions (p = .0041) affected the dimensional stability of the silicone. Statistical significant dimensional differences occurred between groups with (0.071) and without opacifiers (0.053). Accelerated aging influenced the dimensional stability of the samples. All groups scored 2 in the detail reproduction tests, which represents the fully reproducing of three test grooves with accurate angles. Incorporation of opacifiers alters the dimensional stability of silicones used in facial prosthetics, but seems to have no influence on detail reproduction. Accelerated aging is responsible for most of the dimensional changes in Silastic MDX4 4210, but all dimensional changes measured in this study remained within the limits of stability necessary for this application.Keywords
This publication has 31 references indexed in Scilit:
- Influence of Pigments and Opacifiers on Color Stability of an Artificially Aged Facial SiliconeJournal of Prosthodontics, 2010
- Preoperative TRAM Free Flap Volume Estimation for Breast Reconstruction in Lean PatientsAnnals of Plastic Surgery, 2010
- Marginal Deterioration of the Silicone for Facial Prosthesis With Pigments After Effect of Storage Period and Chemical DisinfectionJournal of Craniofacial Surgery, 2010
- Photoelastic Analysis of Stress Distribution in Different Retention Systems for Facial ProsthesisJournal of Craniofacial Surgery, 2009
- Effect of Flasking and Polymerization Techniques on Tooth Movement in Complete Denture ProcessingJournal of Prosthodontics, 2009
- Synthesis of nano-particles of anatase-TiO2 and preparation of its optically transparent film in PVAMaterials Letters, 2007
- Effect of Disinfection on the Dimensional Stability of Polyether Impression MaterialsJournal of Prosthodontics, 2007
- Mechanical properties of carbon nanoparticle-reinforced elastomersComposites Science and Technology, 2003
- Peri-implant soft tissue maintenance in patients with craniofacial implant retained prosthesesInternational Journal of Oral and Maxillofacial Surgery, 2000
- Dimensional Stability of Elastomers for Maxillofacial ApplicationsJournal of Dental Research, 1979