Recommendations for Setting a Criterion and Assessing Commutability of Sample Materials Used in External Quality Assessment/Proficiency Testing Schemes
- 19 September 2023
- journal article
- research article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 69 (11) , 1227-1237
Abstract
It is important for external quality assessment materials (EQAMs) to be commutable with clinical samples; i.e., they should behave like clinical samples when measured using end-user clinical laboratory in vitro diagnostic medical devices (IVD-MDs). Using commutable EQAMs makes it possible to evaluate metrological traceability and/or equivalence of results between IVD-MDs. The criterion for assessing commutability of an EQAM between 2 IVD-MDs is that its result should be within the prediction interval limits based on the statistical distribution of the clinical sample results from the 2 IVD-MDs being compared. The width of the prediction interval is, among other things, dependent on the analytical performance characteristics of the IVD-MDs. A presupposition for using this criterion is that the differences in nonselectivity between the 2 IVD-MDs being compared are acceptable. An acceptable difference in nonselectivity should be small relative to the analytical performance specifications used in the external quality assessment scheme. The acceptable difference in nonselectivity is used to modify the prediction interval criterion for commutability assessment. The present report provides recommendations on how to establish a criterion for acceptable commutability for EQAMS, establish the difference in nonselectivity that can be accepted between IVD-MDs, and perform a commutability assessment. The report also contains examples for performing a commutability assessment of EQAMs.Keywords
This publication has 9 references indexed in Scilit:
- Recommendations for Setting a Criterion for Assessing Commutability of Secondary Calibrator Certified Reference MaterialsClinical Chemistry, 2023
- Interpreting EQA—Understanding Why Commutability of Materials MattersClinical Chemistry, 2022
- The role of external quality assessment in the verification of in vitro medical diagnostics in the traceability eraClinical Biochemistry, 2018
- IFCC Working Group Recommendations for Assessing Commutability Part 2: Using the Difference in Bias between a Reference Material and Clinical SamplesClinical Chemistry, 2018
- IFCC Working Group Recommendations for Assessing Commutability Part 1: General Experimental DesignClinical Chemistry, 2018
- IFCC Working Group Recommendations for Assessing Commutability Part 3: Using the Calibration Effectiveness of a Reference MaterialClinical Chemistry, 2018
- Proof of Safety vs Proof of Hazard1987
- Measurement Error Models1987
- Percentage Points for a Generalized ESD Many-Outlier ProcedureTechnometrics, 1983