DSF Energy Performance Assessment Considering Different Climatic Regions of Iran and Design Parameters
Authors:
- 1 June 2018
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Abstract
Buildings account for over 40% of total energy consumption throughout the world. In recent years, double skin façade (DSF) has gained attention as a solution for energy reduction. However, the performance of DSF varies according to climatic conditions and design parameters such as building orientation, cavity width and glazing type. DSF performance has not yet been fully studied for climatic conditions of Iran. In this regard, a three-story office building with an air-tight DSF is simulated in DesignBuilder software considering three different climatic regions of Iran, namely Tehran, Tabriz and Bandar Abas to assess the impact of orientation, cavity width and glazing types of inner and outer skins. It is found that heating demand of the building correlates strongly with the orientation while the cooling load differs slightly for all the regions under study. With increase in cavity width from 0.4 to 1.2m, heating load is dropped by 0.52 MWh/yr. for Tehran, 0.22 MWh/yr. for Tabriz and 0.2 MWh/yr. for Bandar Abas and the cooling load is reduced by 1.89, 1.48 and 0.08 MWh/yr. for Tehran, Tabriz and Bandar Abas, respectively. Moreover, the study shows that inner skin composition has no significant effect on heating load. Grey double glazing outer skin with the minimum cooling loads of 86.6 MWh/yr. for Tehran, 47.9 MWh/yr. for Tabriz and 154 MWh/yr. for Bandar Abas has the optimal performance.Keywords
This publication has 15 references indexed in Scilit:
- Energy conservation and renewable technologies for buildings to face the impact of the climate change and minimize the use of coolingSolar Energy, 2017
- On The Intrinsic Flexibility of the Double Skin Façade: A Comparative Thermal Comfort Investigation in Tropical and Temperate ClimatesEnergy Procedia, 2017
- Application of passive wall systems for improving the energy efficiency in buildings: A comprehensive reviewRenewable and Sustainable Energy Reviews, 2016
- Energy assessment and optimization of perforated metal sheet double skin façades through Design Builder; A case study in SpainEnergy and Buildings, 2016
- Thermal comfort in naturally ventilated buildings with double skin façade under tropical climate conditions: The influence of key design parametersEnergy and Buildings, 2015
- Life cycle energy and carbon assessment of double skin façades for office refurbishmentsEnergy and Buildings, 2015
- Geo-climatic applicability of natural ventilative cooling in the Mediterranean areaEnergy and Buildings, 2015
- The use of Dynamic Environmental Control Systems (DECS) in Cavities of Double Skin Facades for Energy SavingsProcedia Engineering, 2015
- Heat transfer and air movement behaviour in a double-skin façadeSustainable Cities and Society, 2014
- Investigation on energy performance of double skin façade in Hong KongEnergy and Buildings, 2009