Elin Markarian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Elin Markarian has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Farivar Fazelpour
3 shared publications- Elie Azar
Civil and Environmental Engineering Dept, Carleton University, Ottawa, Canada
2 shared publications - Farivar Fazelpour
Department of Energy Systems Engineering, South Tehran Branch, Islamic Azad University, Tehran, Iran
2 shared publications - Nima Soltani
Young Researchers and Elite Club South Tehran Branch, Islamic Azad University Tehran Iran
2 shared publications - Bora Pulatsu
Department of Civil and Environmental Engineering, Carleton University, Ottawa, Canada
1 shared publication Burak Gunay
1 shared publication
Latest Publications
- Open Access
- 25 July 2026
- Published by Elsevier in Energy Policy
- Vol. 218
Impact of occupancy assumptions in international building codes and standards on building performance and energy conservation measures
- 25 July 2026
- Published by Elsevier in Energy Policy
- Vol. 218
Open AccessImpact of occupancy assumptions in international building codes and standards on building performance and energy conservation measures
- 1 March 2026
- Published by American Society of Civil Engineers (ASCE) in Journal of Computing in Civil Engineering
- Vol. 40 (2)
Machine Learning Surrogates for Unreinforced Masonry Tensile-Strength Prediction
- 1 March 2026
- Published by American Society of Civil Engineers (ASCE) in Journal of Computing in Civil Engineering
- Vol. 40 (2)
Machine Learning Surrogates for Unreinforced Masonry Tensile-Strength Prediction
- 1 October 2019
- Published by Elsevier in Solar Energy
- Vol. 191, 481-496
Multi-objective optimization of energy performance of a building considering different configurations and types of PCM
- 1 October 2019
- Published by Elsevier in Solar Energy
- Vol. 191, 481-496
Multi-objective optimization of energy performance of a building considering different configurations and types of PCM
- 18 March 2019
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 38 (5)
Optimization of wind farm layout considering wake effect and multiple parameters
The output power of wind farms in real world applications is lower than the theoretical output which is largely due to wake effect. So as to maximize the output power, the wake effect of upstream wind turbines on downstream ones should be attenuated. Thus, arrangement of wind turbines in a wind farm is an essential issue that needs to be tackled. This study pursues the aim of finding an optimal layout. Initially, Jensen wake model is applied to simulate the wake effect. Then, genetic algorithm is employed to optimize the wind farm layout considering multiple factors that include different hub heights, rotor diameters, variable induction factors, power and capacity factor curves. Three cases including constant wind–constant direction, constant wind–variable direction and variable wind–variable direction are studied and compared with previous studies. The results indicate that the efficiency of the wind farm for case 1 is 96.71% which is a high record comparing to the previous literature. For Case 2 and 3, the annual wind farm capacity factor (CF) is found to be 97.96 and 97.51%. The power output of Case 1, 2, and 3 are 5.6855 × 108 kWh, 5.6694 × 108 kWh, and 4.5572 × 108 kWh, respectively. © 2019 American Institute of Chemical Engineers Environ Prog, 38:e13146, 2019
- 18 March 2019
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 38 (5)
Optimization of wind farm layout considering wake effect and multiple parameters
The output power of wind farms in real world applications is lower than the theoretical output which is largely due to wake effect. So as to maximize the output power, the wake effect of upstream wind turbines on downstream ones should be attenuated. Thus, arrangement of wind turbines in a wind farm is an essential issue that needs to be tackled. This study pursues the aim of finding an optimal layout. Initially, Jensen wake model is applied to simulate the wake effect. Then, genetic algorithm is employed to optimize the wind farm layout considering multiple factors that include different hub heights, rotor diameters, variable induction factors, power and capacity factor curves. Three cases including constant wind–constant direction, constant wind–variable direction and variable wind–variable direction are studied and compared with previous studies. The results indicate that the efficiency of the wind farm for case 1 is 96.71% which is a high record comparing to the previous literature. For Case 2 and 3, the annual wind farm capacity factor (CF) is found to be 97.96 and 97.51%. The power output of Case 1, 2, and 3 are 5.6855 × 108 kWh, 5.6694 × 108 kWh, and 4.5572 × 108 kWh, respectively. © 2019 American Institute of Chemical Engineers Environ Prog, 38:e13146, 2019
- 29 November 2018
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 38 (2) , 741-749
Impact of building design parameters precision on heating and cooling load calculations
Energy efficiency of buildings is of paramount importance due to limited fossil resources, environmental issues, and increasing energy demand. Thus, in recent years building energy analysis using various programs has experienced a rapid growth. However, these programs are expensive and time consuming. In this study, mechanical engineering building of Tabriz University located in northwest of Iran is analyzed to attain a simplified building model that can reduce the computational time and effort. Therefore, 10 models are considered with distinctive design accuracies. EnergyPlus software has been employed to perform energy analysis of the building. The findings show that building materials, internal walls and zoning of the building are determining factors in thermal loads of the building. However, shadings, number of occupants, and electrical appliances have negligible impact. Thus, it can be concluded that the model in which a detailed envelope design is considered and interior walls, shades, electrical appliances, and duration of occupancy are omitted, has the optimum performance in terms of time saving and accuracy of load calculation. Moreover, to gain more reliable results, it is recommended to consider zones in model No.5. The difference between natural gas and electricity consumption of the first and last models is 20,302 m3 (2200$) and 1157 kWh (90$) that indicates the significance of proper HAVC sizing. It is worth mentioning that all monetary units are presented in 2018 U.S. dollar. © 2018 American Institute of Chemical Engineers Environ Prog, 38: 741–749, 2019
- 29 November 2018
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 38 (2) , 741-749
Impact of building design parameters precision on heating and cooling load calculations
Energy efficiency of buildings is of paramount importance due to limited fossil resources, environmental issues, and increasing energy demand. Thus, in recent years building energy analysis using various programs has experienced a rapid growth. However, these programs are expensive and time consuming. In this study, mechanical engineering building of Tabriz University located in northwest of Iran is analyzed to attain a simplified building model that can reduce the computational time and effort. Therefore, 10 models are considered with distinctive design accuracies. EnergyPlus software has been employed to perform energy analysis of the building. The findings show that building materials, internal walls and zoning of the building are determining factors in thermal loads of the building. However, shadings, number of occupants, and electrical appliances have negligible impact. Thus, it can be concluded that the model in which a detailed envelope design is considered and interior walls, shades, electrical appliances, and duration of occupancy are omitted, has the optimum performance in terms of time saving and accuracy of load calculation. Moreover, to gain more reliable results, it is recommended to consider zones in model No.5. The difference between natural gas and electricity consumption of the first and last models is 20,302 m3 (2200$) and 1157 kWh (90$) that indicates the significance of proper HAVC sizing. It is worth mentioning that all monetary units are presented in 2018 U.S. dollar. © 2018 American Institute of Chemical Engineers Environ Prog, 38: 741–749, 2019
- Open Access
- 13 November 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (23) , 1487
Impact of Multiple Parameters on Energy Performance of PV-DSF Buildings
Double Skin Façade (DSF) has been widely used in buildings to enhance energy efficiency and bring daylight and aesthetic benefits. Solar photovoltaic (PV) modules can be integrated in DSF to fully or partially meet the electricity demand. Therefore, in this study, the energy performance of a 3-storey PV-DSF building is analyzed for three cities of Iran with distinctive climates namely Tehran, Tabriz and Kish Island considering different orientations, cavity widths and different optical properties for the PV system. The results indicated that the south facing PV-DSF have the maximum electricity generation and the minimum net electricity consumption. With increase in cavity width from 0.4 to 1.2 m, the annual electricity consumption is reduced by 5.88, 5.19 and 7.49 MWh for Tehran, Tabriz and Kish, respectively. The cavity width tends to have negligible impact on electricity generation. The analysis of the outer PV skin showed that the glazing with lower Solar Heat Gain Coefficient (SHGC) offers more energy saving benefits for all the considered cities.
- 13 November 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (23) , 1487
Open AccessImpact of Multiple Parameters on Energy Performance of PV-DSF Buildings
Double Skin Façade (DSF) has been widely used in buildings to enhance energy efficiency and bring daylight and aesthetic benefits. Solar photovoltaic (PV) modules can be integrated in DSF to fully or partially meet the electricity demand. Therefore, in this study, the energy performance of a 3-storey PV-DSF building is analyzed for three cities of Iran with distinctive climates namely Tehran, Tabriz and Kish Island considering different orientations, cavity widths and different optical properties for the PV system. The results indicated that the south facing PV-DSF have the maximum electricity generation and the minimum net electricity consumption. With increase in cavity width from 0.4 to 1.2 m, the annual electricity consumption is reduced by 5.88, 5.19 and 7.49 MWh for Tehran, Tabriz and Kish, respectively. The cavity width tends to have negligible impact on electricity generation. The analysis of the outer PV skin showed that the glazing with lower Solar Heat Gain Coefficient (SHGC) offers more energy saving benefits for all the considered cities.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
DSF Energy Performance Assessment Considering Different Climatic Regions of Iran and Design Parameters
Buildings account for over 40% of total energy consumption throughout the world. In recent years, double skin façade (DSF) has gained attention as a solution for energy reduction. However, the performance of DSF varies according to climatic conditions and design parameters such as building orientation, cavity width and glazing type. DSF performance has not yet been fully studied for climatic conditions of Iran. In this regard, a three-story office building with an air-tight DSF is simulated in DesignBuilder software considering three different climatic regions of Iran, namely Tehran, Tabriz and Bandar Abas to assess the impact of orientation, cavity width and glazing types of inner and outer skins. It is found that heating demand of the building correlates strongly with the orientation while the cooling load differs slightly for all the regions under study. With increase in cavity width from 0.4 to 1.2m, heating load is dropped by 0.52 MWh/yr. for Tehran, 0.22 MWh/yr. for Tabriz and 0.2 MWh/yr. for Bandar Abas and the cooling load is reduced by 1.89, 1.48 and 0.08 MWh/yr. for Tehran, Tabriz and Bandar Abas, respectively. Moreover, the study shows that inner skin composition has no significant effect on heating load. Grey double glazing outer skin with the minimum cooling loads of 86.6 MWh/yr. for Tehran, 47.9 MWh/yr. for Tabriz and 154 MWh/yr. for Bandar Abas has the optimal performance.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
DSF Energy Performance Assessment Considering Different Climatic Regions of Iran and Design Parameters
Buildings account for over 40% of total energy consumption throughout the world. In recent years, double skin façade (DSF) has gained attention as a solution for energy reduction. However, the performance of DSF varies according to climatic conditions and design parameters such as building orientation, cavity width and glazing type. DSF performance has not yet been fully studied for climatic conditions of Iran. In this regard, a three-story office building with an air-tight DSF is simulated in DesignBuilder software considering three different climatic regions of Iran, namely Tehran, Tabriz and Bandar Abas to assess the impact of orientation, cavity width and glazing types of inner and outer skins. It is found that heating demand of the building correlates strongly with the orientation while the cooling load differs slightly for all the regions under study. With increase in cavity width from 0.4 to 1.2m, heating load is dropped by 0.52 MWh/yr. for Tehran, 0.22 MWh/yr. for Tabriz and 0.2 MWh/yr. for Bandar Abas and the cooling load is reduced by 1.89, 1.48 and 0.08 MWh/yr. for Tehran, Tabriz and Bandar Abas, respectively. Moreover, the study shows that inner skin composition has no significant effect on heating load. Grey double glazing outer skin with the minimum cooling loads of 86.6 MWh/yr. for Tehran, 47.9 MWh/yr. for Tabriz and 154 MWh/yr. for Bandar Abas has the optimal performance.
- 1 August 2017
- Published by Elsevier in Renewable Energy
- Vol. 109, 646-667
Wind energy potential and economic assessment of four locations in Sistan and Balouchestan province in Iran
- 1 August 2017
- Published by Elsevier in Renewable Energy
- Vol. 109, 646-667
Wind energy potential and economic assessment of four locations in Sistan and Balouchestan province in Iran