Improved quantitative19F MR molecular imaging with flip angle calibration andB1-mapping compensation
- 25 November 2014
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 42 (2) , 488-494
Abstract
Purpose To improve 19F flip angle calibration and compensate for B1 inhomogeneities in quantitative 19F MRI of sparse molecular epitopes with perfluorocarbon (PFC) nanoparticle (NP) emulsion contrast agents. Materials and Methods Flip angle sweep experiments on PFC‐NP point source phantoms with three custom‐designed 19F/1H dual‐tuned coils revealed a difference in required power settings for 19F and 1H nuclei, which was used to calculate a calibration ratio specific for each coil. An image‐based correction technique was developed using B1‐field mapping on 1H to correct for 19F and 1H images in two phantom experiments. Results Optimized 19F peak power differed significantly from that of 1H power for each coil (P < 0.05). A ratio of 19F/1H power settings yielded a coil‐specific and spatially independent calibration value (surface: 1.48 ± 0.06; semicylindrical: 1.71 ± 0.02, single‐turn‐solenoid: 1.92 ± 0.03). 1H‐image‐based B1 correction equalized the signal intensity of 19F images for two identical 19F PFC‐NP samples placed in different parts of the field, which were offset significantly by ∼66% (P < 0.001), before correction. Conclusion 19F flip angle calibration and B1‐mapping compensations to the 19F images employing the more abundant 1H signal as a basis for correction resulted in a significant change in the quantification of sparse 19F MR signals from targeted PFC NP emulsions. J. Magn. Reson. Imaging 2015;42:488–494.Keywords
This publication has 28 references indexed in Scilit:
- Transmit field inhomogeneity and T1estimation errors in breast DCE‐MRI at 3 teslaJournal of Magnetic Resonance Imaging, 2013
- A generalized strategy for designing 19F/1H dual‐frequency MRI coil for small animal imaging at 4.7 TeslaJournal of Magnetic Resonance Imaging, 2011
- Simultaneous dual‐nuclei imaging for motion corrected detection and quantification of 19F imaging agentsMagnetic Resonance in Medicine, 2011
- Simultaneous Dual Frequency $^{1}{\rm H}$ and $^{19}{\rm F}$ Open Coil Imaging of Arthritic Rabbit Knee at 3TIEEE Transactions on Medical Imaging, 2010
- Three‐dimensional MR mapping of angiogenesis with α 5 β 1 (α v β 3 )‐targeted theranostic nanoparticles in the MDA‐MB‐435 xenograft mouse modelThe FASEB Journal, 2008
- Fluorine magnetic resonance in vivo: A powerful tool in the study of drug distribution and metabolismDrug Discovery Today, 2008
- Imaging of Vx‐2 rabbit tumors with ανβ3‐integrin‐targeted 111In nanoparticlesInternational Journal of Cancer, 2007
- Three‐dimensional radial ultrashort echo‐time imaging with T2 adapted samplingMagnetic Resonance in Medicine, 2006
- Iron oxide MR contrast agents for molecular and cellular imagingNMR in Biomedicine, 2004
- Targeted nanoparticles for quantitative imaging of sparse molecular epitopes with MRIMagnetic Resonance in Medicine, 2004