Lateral load behaviour of a rectangular precast shear wall involving vertical bolted connections
- 8 November 2018
- journal article
- research article
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 22 (5) , 1211-1224
Abstract
This article is concerned about precast reinforced concrete shear walls and the methods of assembling shear wall panels to form a reliable load transfer system. An assembling method is proposed using dry connection through an H-shaped steel connector (H-connector) and high-strength bolts. A preliminary design, including the H-connector design and bolt design, has been carried out based on the force analysis on the vertical connection in the wall assembly. On the basis of the finite element analysis verified by an experimental study, the preliminary design has been confirmed and a monolithic coefficient (ζ) has been used to evaluate the cooperative working performance of the two parallel shear walls. Then this article continues to carry out a finite element parametric study on the mechanical behaviour of the precast reinforced concrete shear walls with varying parameters, which includes the bolt specification, the frictional coefficient on the contact surface within the bolted connection and the thickness of the H-connector flange. The lateral load bearing capacity, lateral stiffness and cooperative working performance of the wall assemblies involving these varying parameters have been broadly analysed.Keywords
Funding Information
- Natural Science Foundation of Jiangsu Province (BK20170668)
- the Fundamental Research Funds for the Central Universities
- National Natural Science Foundation of China (51708107)
This publication has 25 references indexed in Scilit:
- Experimental study of L‐shaped precast RC shear walls with middle cast‐in‐situ jointThe Structural Design of Tall and Special Buildings, 2017
- An Experimental Study of Welded Bar Sleeve Wall Panel Connection under Tensile, Shear, and Flexural LoadsInternational Journal of Concrete Structures and Materials, 2017
- Experimental and analytical study on grouted duct connections in precast concrete constructionMaterials and Structures, 2017
- Shake-Table Test of a Full-Scale 4-Story Precast Concrete Building. II: Analytical StudiesJournal of Structural Engineering, 2017
- Cyclic Lateral Testing of Precast Concrete T-Walls in Fast Low-Rise ConstructionACI Structural Journal, 2016
- BEHAVIOR AND SIMPLIFIED MODELING OF MECHANICAL REINFORCING BAR SPLICESACI Structural Journal, 2015
- Development of a Precast Concrete Shear-Wall System Requiring Special Code AcceptancePCI Journal, 2007
- DUCTILE STEEL CONNECTIONS FOR SEISMIC RESISTANT PRECAST BUILDINGSJournal of Earthquake Engineering, 2003
- Plastic-Damage Model for Cyclic Loading of Concrete StructuresJournal of Engineering Mechanics, 1998
- A plastic-damage model for concreteInternational Journal of Solids and Structures, 1989