Amount of adsorbed albumin loss by dialysis membranes with protein adsorption
- 19 September 2009
- journal article
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 12 (3) , 194-199
Abstract
Polymethylmethacrylate (PMMA) membrane is the first synthetic polymeric hollow fiber used in dialyzers that is known to adsorb β2-microglobulin. Polyester polymer alloy (PEPA), a blend of two polymers, i.e., polyarylate and polyethersulfone, is another dialysis membrane material with adsorption characteristics. In this study, the adsorption and permeation characteristics of BG-1.6PQ (PMMA) and FLX-15GW (PEPA) dialyzers were investigated by performing ultrafiltration experiments using chymotrypsinogen (molecular weight 25 000) and albumin (molecular weight 66 000) as test solutes. Although PMMA and PEPA had the same sieving coefficient for chymotrypsinogen at steady state, PMMA showed approximately 20% higher fractional adsorption than PEPA under the same initial concentrations. The fractional adsorption for albumin was approximately 20% in PEPA regardless of the ultrafiltration flow rate. The fractional adsorption for albumin in PMMA, however, increased as the ultrafiltration flow rate increased and reached 50%–60% after 10 h. Since PEPA has two skins, one inside and one outside the hollow fiber, proteins may have been adsorbed mainly by these two layers. However, since PMMA is a uniform membrane and since the higher the ultrafiltration flow rate, the higher the fractional adsorption found in PMMA, adsorption may be the result of the occlusion of the dense structure of the membrane. The amount of albumin loss is often clinically evaluated by measuring the amount of permeated albumin in the dialysate. However, when dialyzers with adsorption characteristics are examined, the loss by adsorption should also be taken into account.Keywords
This publication has 7 references indexed in Scilit:
- Continuous Hemodiafiltration with PMMA Hemofilter in the Treatment of Patients with Septic ShockMolecular Medicine, 2008
- Clinical significance of protein adsorbable membranes--Long-term clinical effects and analysis using a proteomic techniqueNephrology Dialysis Transplantation, 2007
- Continuous Hemodiafiltration with Cytokine-Adsorbing Hemofilter in the Treatment of Severe Sepsis and Septic Shock2007
- Membrane fouling and dialysate flow pattern in an internal filtration-enhancing dialyzerJournal of Artificial Organs, 2005
- Current Topics on Cytokine Removal TechnologiesTherapeutic Apheresis, 2001
- New polymer alloy dialysis membranes with varying permeabilities and sievings.1992
- A new form of amyloid protein associated with chronic hemodialysis was identified as β2-microglobulinBiochemical and Biophysical Research Communications, 1985