Akihiro C. Yamashita
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Akihiro C. Yamashita has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Niyazi Ercan
Yuksek Ihtisas Universitesi
7 shared publications Narumi Tomisawa
Department of Human and Environmental Science College of Engineering Shonan Institute of Technology Fujisawa Kanagawa Japan
6 shared publications- Hideki Kawanishi
Akane Foundation, Tsuchiya General Hospital, Hiroshima, Japan
4 shared publications Kakuji J. Tojo
Department of Biochemical Engineering and Science, Kyushu Institute of Technology, Fukuoka
3 shared publicationsMakoto Ishizaki
Eijinkai Hospital
3 shared publicationsMasahiko Nakamoto
Saiseikai Yahata General Hospital
3 shared publications
Latest Publications
- Open Access
- 15 June 2022
- Published by Springer Nature in Renal Replacement Therapy
- Vol. 8 (1) , 1
Retraction Note: Impact of the third wave of the COVID-19 pandemic and interventions to contain the virus on society and patients with kidney disease in Cambodia
[This retracts the article DOI: 10.1186/s41100-021-00372-6.].
- 15 June 2022
- Published by Springer Nature in Renal Replacement Therapy
- Vol. 8 (1) , 1
Open AccessRetraction Note: Impact of the third wave of the COVID-19 pandemic and interventions to contain the virus on society and patients with kidney disease in Cambodia
[This retracts the article DOI: 10.1186/s41100-021-00372-6.].
- 1 February 2013
- Published by S. Karger AG in Blood Purification
- Vol. 35 (Suppl. 1) , 29-33
Diafilters for Predilution and Postdilution On-Line Hemodiafiltration
When hemodiafiltration (HDF) is performed, we can choose the point on the blood circuit where the substitution fluid goes in, i.e. before the diafilter (predilution) or after the diafilter (postdilution). We must avoid unexpected loss of albumin; however, we should remove a certain amount of albumin in order to remove much larger solutes than β2-microglobulin and obtain better clinical outcomes. Previously, ultrafiltration experiments were performed in vitro using aqueous albumin solution and commercial diafilters. The results showed a high sieving coefficient for albumin right after starting the experiment that is identical to several clinical reports. Based on these results, a novel design of the diafilter was attempted for predilution and postdilution HDF. Diafilters for predilution HDF do not require much change in design specifications, employing hollow fibers with a slightly larger diameter in order to reduce high blood pressure caused by the high blood flow rate. Diafilters for postdilution HDF may require much change, including shortening the length in order to reduce the amount of internal filtration. Diafilters specifically designed for predilution or postdilution may be necessary to assure future success of clinical HDF treatment.
- 1 February 2013
- Published by S. Karger AG in Blood Purification
- Vol. 35 (Suppl. 1) , 29-33
Diafilters for Predilution and Postdilution On-Line Hemodiafiltration
When hemodiafiltration (HDF) is performed, we can choose the point on the blood circuit where the substitution fluid goes in, i.e. before the diafilter (predilution) or after the diafilter (postdilution). We must avoid unexpected loss of albumin; however, we should remove a certain amount of albumin in order to remove much larger solutes than β2-microglobulin and obtain better clinical outcomes. Previously, ultrafiltration experiments were performed in vitro using aqueous albumin solution and commercial diafilters. The results showed a high sieving coefficient for albumin right after starting the experiment that is identical to several clinical reports. Based on these results, a novel design of the diafilter was attempted for predilution and postdilution HDF. Diafilters for predilution HDF do not require much change in design specifications, employing hollow fibers with a slightly larger diameter in order to reduce high blood pressure caused by the high blood flow rate. Diafilters for postdilution HDF may require much change, including shortening the length in order to reduce the amount of internal filtration. Diafilters specifically designed for predilution or postdilution may be necessary to assure future success of clinical HDF treatment.
- 4 October 2012
- Published by Wiley in Hemodialysis International
- Vol. 16, S10-S14
Effect of sterilization on solute transport performances of super high-flux dialyzers
- 4 October 2012
- Published by Wiley in Hemodialysis International
- Vol. 16, S10-S14
Effect of sterilization on solute transport performances of super high-flux dialyzers
- 20 October 2011
- Published by Wiley in Hemodialysis International
- Vol. 15 (S1) , S15-S21
What is good about PD + HD combined therapy
It is known that β2-microglobulin (β2-MG) concentration in peritoneal dialysis (PD) patients is inversely correlated to the residual renal function (RRF). With decreasing RRF, some PD patients may necessarily be treated with hemodialysis (HD) once a week, not only for removing excess water and small solutes, but also for removing much larger solutes such as β2-MG. In this study, a kinetic model allowed us to show what is good about PD + HD combined therapy in long-term PD patients. A mathematical model was established based on a classic compartment theory for clinical use. Model validations were made by comparing calculated results with clinical data in order to specify what was good about PD + HD combined therapy (5-day PD + 1-HD/week). Time-averaged concentration (TAC) for urea and creatinine decreased by 20% on the average by introducing PD+HD combined therapy no matter which dialyzers were used. TAC for β2-MG in PD+HD combined therapy, however, was strongly dependent upon the dialyzer clearance, and when a low flux dialyzer (clearance for β2-MG = 10 mL/min under QB = 200, QD = 500 mL/min) was used, pre-dialysis β2-MG concentration may increase. Use of super high-flux dialyzers (clearance for β2-MG = 60 mL/min under the same conditions) should greatly reduce the β2-MG concentration from 30 to 8 mg/L in 4-hr treatment. Then, when PD+HD combined therapy is introduced to a PD patient with diminishing RRF, use of super high-flux dialyzers may be strongly recommended in order not to increase concentrations of pre-dialysis β2-MG and/or even greater solutes. Use of super high-flux dialyzers is a key to the success of PD+HD combined therapy that could prevent concentrations of large solutes from increasing.
- 20 October 2011
- Published by Wiley in Hemodialysis International
- Vol. 15 (S1) , S15-S21
What is good about PD + HD combined therapy
It is known that β2-microglobulin (β2-MG) concentration in peritoneal dialysis (PD) patients is inversely correlated to the residual renal function (RRF). With decreasing RRF, some PD patients may necessarily be treated with hemodialysis (HD) once a week, not only for removing excess water and small solutes, but also for removing much larger solutes such as β2-MG. In this study, a kinetic model allowed us to show what is good about PD + HD combined therapy in long-term PD patients. A mathematical model was established based on a classic compartment theory for clinical use. Model validations were made by comparing calculated results with clinical data in order to specify what was good about PD + HD combined therapy (5-day PD + 1-HD/week). Time-averaged concentration (TAC) for urea and creatinine decreased by 20% on the average by introducing PD+HD combined therapy no matter which dialyzers were used. TAC for β2-MG in PD+HD combined therapy, however, was strongly dependent upon the dialyzer clearance, and when a low flux dialyzer (clearance for β2-MG = 10 mL/min under QB = 200, QD = 500 mL/min) was used, pre-dialysis β2-MG concentration may increase. Use of super high-flux dialyzers (clearance for β2-MG = 60 mL/min under the same conditions) should greatly reduce the β2-MG concentration from 30 to 8 mg/L in 4-hr treatment. Then, when PD+HD combined therapy is introduced to a PD patient with diminishing RRF, use of super high-flux dialyzers may be strongly recommended in order not to increase concentrations of pre-dialysis β2-MG and/or even greater solutes. Use of super high-flux dialyzers is a key to the success of PD+HD combined therapy that could prevent concentrations of large solutes from increasing.
- Open Access
- 1 January 2011
- Published by S. Karger AG
- Vol. 173, 191-195
Commercially Available High-Performance Membrane Dialyzers and Several Special Kinds on the Japanese Market (as of April 30, 2011)
- 1 January 2011
- Published by S. Karger AG
- Vol. 173, 191-195
Open AccessCommercially Available High-Performance Membrane Dialyzers and Several Special Kinds on the Japanese Market (as of April 30, 2011)
- 6 October 2010
- Published by Wiley in Hemodialysis International
- Vol. 14 (s1) , S7-S13
Which solute removal mechanism dominates over others in dialyzers for continuous renal replacement therapy?
Selecting dialyzers is more important for blood purification in critical care because other therapeutic options (especially amount of dialysate) are usually limited. Adsorption is a major mechanism of removing toxic substances from patients in these treatments. Several commercial dialyzers designed for acute blood purification therapy were investigated by performing aqueous ultrafiltration experiments to demonstrate the adsorptive importance of membrane materials. Polymethylmethacrylate showed strong adsorptive characteristics to α‐chymotripsinogen A (MW 25,000) but showed much less adsorptive characteristics to cytochrome C (MW 12,400). On the contrary, polyacrylonitrile showed relatively lower affinity and polysulfone showed essentially no affinity to these proteins. Time‐dependent and concentration‐dependent characteristics of clearance for these solutes were also demonstrated in polymethylmethacrylate. Adsorption found in polymethylmethacrylate may be due to the occlusion of protein molecules into pores of the membrane. Choosing membrane materials is, therefore, important not only in removing inflammatory cytokines but also for accounting for the loss of albumin in acute and chronic treatments.
- 6 October 2010
- Published by Wiley in Hemodialysis International
- Vol. 14 (s1) , S7-S13
Which solute removal mechanism dominates over others in dialyzers for continuous renal replacement therapy?
Selecting dialyzers is more important for blood purification in critical care because other therapeutic options (especially amount of dialysate) are usually limited. Adsorption is a major mechanism of removing toxic substances from patients in these treatments. Several commercial dialyzers designed for acute blood purification therapy were investigated by performing aqueous ultrafiltration experiments to demonstrate the adsorptive importance of membrane materials. Polymethylmethacrylate showed strong adsorptive characteristics to α‐chymotripsinogen A (MW 25,000) but showed much less adsorptive characteristics to cytochrome C (MW 12,400). On the contrary, polyacrylonitrile showed relatively lower affinity and polysulfone showed essentially no affinity to these proteins. Time‐dependent and concentration‐dependent characteristics of clearance for these solutes were also demonstrated in polymethylmethacrylate. Adsorption found in polymethylmethacrylate may be due to the occlusion of protein molecules into pores of the membrane. Choosing membrane materials is, therefore, important not only in removing inflammatory cytokines but also for accounting for the loss of albumin in acute and chronic treatments.
- 1 January 2010
- Published by Taylor & Francis in JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
- Vol. 43 (6) , 521-528
Filtration and Adsorption of Albumin in Commercial Hemofilters
- 1 January 2010
- Published by Taylor & Francis in JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
- Vol. 43 (6) , 521-528
Filtration and Adsorption of Albumin in Commercial Hemofilters
- 22 September 2009
- Published by Wiley in Hemodialysis International
- Vol. 13 (s1) , S2-S7
Effect of packing density of hollow fibers on solute removal performances of dialyzers
Solute removal performances of dialyzers are dependent not only on the solute permeabilities of the membrane but also on the module design. We have investigated how the packing density of hollow fiber (PDF) affects the solute removal performances. A series of 4 polyester polymer alloy membrane test dialyzers were assembled with varying PDFs of 29.6%, 35.3%, 44.1%, and 53.1%. Clearances (CL) were measured in vitro for creatinine (MW113), vitamin B12 (MW1355), and chymotrypsin (MW25300) with various QB=100 to 400 and QD=350 to 650 mL/min in the absence of net ultrafiltration. When QB was ≤300 mL/min, no significant changes were found in creatinine CL with the increase of PDF up to 35.3%. A slightly greater increase was found in CL when QB=400 mL/min. Clearances for vitamin B12, however, increased with the increase of PDF in the range of 29.6% to 35.3%. The effects of PDF on CL were greater with larger QB. More importantly, an abrupt increase of CL was found when PDF was increased from 44.1% to 53.1%. According to a rigorous mathematical model, this may be caused by the internal filtration, which is reverse ultrafiltration occurring in a dialyzer at any given time. No significant increase was found in chymotrypsin CL when the PDF was ≤35.3%, which suggested that CL for large molecules was strongly dependent on the solute permeability rather than the conditions of flow patterns. A very steep increase was also found in CL for chymotrypsin when the PDF was >44.1%, which was also considered to be due to the internal filtration. Packing density of hollow fiber can be optimized in terms of solute removal performances when the target solute and therapeutic conditions are specified.
- 22 September 2009
- Published by Wiley in Hemodialysis International
- Vol. 13 (s1) , S2-S7
Effect of packing density of hollow fibers on solute removal performances of dialyzers
Solute removal performances of dialyzers are dependent not only on the solute permeabilities of the membrane but also on the module design. We have investigated how the packing density of hollow fiber (PDF) affects the solute removal performances. A series of 4 polyester polymer alloy membrane test dialyzers were assembled with varying PDFs of 29.6%, 35.3%, 44.1%, and 53.1%. Clearances (CL) were measured in vitro for creatinine (MW113), vitamin B12 (MW1355), and chymotrypsin (MW25300) with various QB=100 to 400 and QD=350 to 650 mL/min in the absence of net ultrafiltration. When QB was ≤300 mL/min, no significant changes were found in creatinine CL with the increase of PDF up to 35.3%. A slightly greater increase was found in CL when QB=400 mL/min. Clearances for vitamin B12, however, increased with the increase of PDF in the range of 29.6% to 35.3%. The effects of PDF on CL were greater with larger QB. More importantly, an abrupt increase of CL was found when PDF was increased from 44.1% to 53.1%. According to a rigorous mathematical model, this may be caused by the internal filtration, which is reverse ultrafiltration occurring in a dialyzer at any given time. No significant increase was found in chymotrypsin CL when the PDF was ≤35.3%, which suggested that CL for large molecules was strongly dependent on the solute permeability rather than the conditions of flow patterns. A very steep increase was also found in CL for chymotrypsin when the PDF was >44.1%, which was also considered to be due to the internal filtration. Packing density of hollow fiber can be optimized in terms of solute removal performances when the target solute and therapeutic conditions are specified.
- 19 September 2009
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 12 (3) , 194-199
Amount of adsorbed albumin loss by dialysis membranes with protein adsorption
Polymethylmethacrylate (PMMA) membrane is the first synthetic polymeric hollow fiber used in dialyzers that is known to adsorb β2-microglobulin. Polyester polymer alloy (PEPA), a blend of two polymers, i.e., polyarylate and polyethersulfone, is another dialysis membrane material with adsorption characteristics. In this study, the adsorption and permeation characteristics of BG-1.6PQ (PMMA) and FLX-15GW (PEPA) dialyzers were investigated by performing ultrafiltration experiments using chymotrypsinogen (molecular weight 25 000) and albumin (molecular weight 66 000) as test solutes. Although PMMA and PEPA had the same sieving coefficient for chymotrypsinogen at steady state, PMMA showed approximately 20% higher fractional adsorption than PEPA under the same initial concentrations. The fractional adsorption for albumin was approximately 20% in PEPA regardless of the ultrafiltration flow rate. The fractional adsorption for albumin in PMMA, however, increased as the ultrafiltration flow rate increased and reached 50%–60% after 10 h. Since PEPA has two skins, one inside and one outside the hollow fiber, proteins may have been adsorbed mainly by these two layers. However, since PMMA is a uniform membrane and since the higher the ultrafiltration flow rate, the higher the fractional adsorption found in PMMA, adsorption may be the result of the occlusion of the dense structure of the membrane. The amount of albumin loss is often clinically evaluated by measuring the amount of permeated albumin in the dialysate. However, when dialyzers with adsorption characteristics are examined, the loss by adsorption should also be taken into account.
- 19 September 2009
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 12 (3) , 194-199
Amount of adsorbed albumin loss by dialysis membranes with protein adsorption
Polymethylmethacrylate (PMMA) membrane is the first synthetic polymeric hollow fiber used in dialyzers that is known to adsorb β2-microglobulin. Polyester polymer alloy (PEPA), a blend of two polymers, i.e., polyarylate and polyethersulfone, is another dialysis membrane material with adsorption characteristics. In this study, the adsorption and permeation characteristics of BG-1.6PQ (PMMA) and FLX-15GW (PEPA) dialyzers were investigated by performing ultrafiltration experiments using chymotrypsinogen (molecular weight 25 000) and albumin (molecular weight 66 000) as test solutes. Although PMMA and PEPA had the same sieving coefficient for chymotrypsinogen at steady state, PMMA showed approximately 20% higher fractional adsorption than PEPA under the same initial concentrations. The fractional adsorption for albumin was approximately 20% in PEPA regardless of the ultrafiltration flow rate. The fractional adsorption for albumin in PMMA, however, increased as the ultrafiltration flow rate increased and reached 50%–60% after 10 h. Since PEPA has two skins, one inside and one outside the hollow fiber, proteins may have been adsorbed mainly by these two layers. However, since PMMA is a uniform membrane and since the higher the ultrafiltration flow rate, the higher the fractional adsorption found in PMMA, adsorption may be the result of the occlusion of the dense structure of the membrane. The amount of albumin loss is often clinically evaluated by measuring the amount of permeated albumin in the dialysate. However, when dialyzers with adsorption characteristics are examined, the loss by adsorption should also be taken into account.
- 1 June 2009
- Published by S. Karger AG in Blood Purification
- Vol. 27 (Suppl. 1) , 50-55
Central Online Hemodiafiltration in Japan: Management of Water Quality and Practice
Hemodiafiltration (HDF) includes a variety of technologies and preparation of ultrapure dialysis fluid has made it possible to perform online HDF and its extensive alternatives. According to current statistics, 5.8% of ESRD patients are treated with HDF in Japan. The majority of these HDF treatments are performed using the central dialysis fluid delivery system (CDDS), this is because most Japanese clinicians and researchers consider that with CDDS it is easier to prepare substitution fluid; moreover, CDDS has economical advantages against single-patient dialysis machine (SPDM)-based counterparts. The water quality at each patient station (dialysis console) is regularly validated by bacterial culture (colony-forming units) and by measuring endotoxin concentration (ET). Since ET measurement takes much less time than bacterial culture, ET is often used as an indicator to verify the water quality for online use. Dialysis fluid with ET below the detection level (usually <0.001 EU/ml) is used for online substitution. In CDDS online HDF, since dialysis clinics must prepare not only the dialysis fluid but also the substitution fluid, they need to satisfy almost the same requirements as pharmaceutical water treatment factories do. The Japanese Society for Dialysis Therapy (JSDT) together with the Japanese Society for Hemodiafiltration (JS-HDF) is now preparing guidelines to meet all these necessary requirements on a worldwide basis.
- 1 June 2009
- Published by S. Karger AG in Blood Purification
- Vol. 27 (Suppl. 1) , 50-55
Central Online Hemodiafiltration in Japan: Management of Water Quality and Practice
Hemodiafiltration (HDF) includes a variety of technologies and preparation of ultrapure dialysis fluid has made it possible to perform online HDF and its extensive alternatives. According to current statistics, 5.8% of ESRD patients are treated with HDF in Japan. The majority of these HDF treatments are performed using the central dialysis fluid delivery system (CDDS), this is because most Japanese clinicians and researchers consider that with CDDS it is easier to prepare substitution fluid; moreover, CDDS has economical advantages against single-patient dialysis machine (SPDM)-based counterparts. The water quality at each patient station (dialysis console) is regularly validated by bacterial culture (colony-forming units) and by measuring endotoxin concentration (ET). Since ET measurement takes much less time than bacterial culture, ET is often used as an indicator to verify the water quality for online use. Dialysis fluid with ET below the detection level (usually <0.001 EU/ml) is used for online substitution. In CDDS online HDF, since dialysis clinics must prepare not only the dialysis fluid but also the substitution fluid, they need to satisfy almost the same requirements as pharmaceutical water treatment factories do. The Japanese Society for Dialysis Therapy (JSDT) together with the Japanese Society for Hemodiafiltration (JS-HDF) is now preparing guidelines to meet all these necessary requirements on a worldwide basis.