Abstract
Background: The DynamX bioadaptor is a novel coronary implant with three helical strands that unlock and separate to provide dynamic vessel support restoring natural vessel function. Evidence in complex bifurcation lesions requiring planned two-stent strategies is limited. This analysis evaluated the feasibility and short-term outcomes of culotte bioadaptor implantation using intravascular ultrasound (IVUS). Methods: Thirteen consecutive patients underwent bifurcation percutaneous coronary intervention using culotte technique with DynamX bioadaptor between February and October 2025. All procedures followed a standardized culotte protocol with lesion preparation, proximal optimization technique, rewiring, and final kissing balloon inflation, with IVUS used to assess bioadaptor expansion, apposition, and structural integrity. Results: Technical and procedural success was achieved in all patients (100%), with successful rewiring through bioadaptor struts in all attempts (26 of 26, 100%). IVUS demonstrated satisfactory expansion: main branch ostial expansion 94.9% ± 10.6%, side branch ostial expansion 90.2% ± 17.5%, and proximal expansion ratio 0.95 ± 0.16. No strut fractures or malapposition occurred. Conclusions: Early experience with bioadaptor implantation in culotte bifurcation stenting demonstrates feasibility, with favorable acute IVUS findings in selected patients.Keywords
All Related Versions
This publication has 38 references indexed in Scilit:
- First randomised controlled trial comparing the sirolimus-eluting bioadaptor with the zotarolimus-eluting drug-eluting stent in patients with de novo coronary artery lesions: 12-month clinical and imaging data from the multi-centre, international, BIODAPTOR-RCTeClinicalMedicine, 2023
- 24-Month Clinical Follow-Up and Mechanistic Insights From Intravascular Imaging Following Coronary Implantation of the Novel DynamX Bioadaptor PlatformCardiovascular Revascularization Medicine, 2022
- Ultrathin Bioresorbable Polymer Sirolimus-Eluting Stents Versus Thin Durable Polymer Everolimus-Eluting StentsJACC, 2018
- Fourth Universal Definition of Myocardial Infarction (2018)JACC, 2018
- Kissing Balloon or Sequential Dilation of the Side Branch and Main Vessel for Provisional Stenting of BifurcationsJACC: Cardiovascular Interventions, 2012
- The Pathology of Neoatherosclerosis in Human Coronary ImplantsJACC, 2011
- Developments in metallic biodegradable stents☆Acta Biomaterialia, 2010
- The evolution of cardiovascular stent materials and surfaces in response to clinical drivers: A reviewActa Biomaterialia, 2009
- Role of Endothelial Shear Stress in the Natural History of Coronary Atherosclerosis and Vascular RemodelingJACC, 2007
- Pathology of Drug-Eluting Stents in HumansJACC, 2006