DVDong Tran Van

Dong Tran Van

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dong Tran Van has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Feasibility and short-term outcomes of bioadaptor in bifurcation intervention using culotte technique: intravascular ultrasound analysis from a single-center experience

    by Van Hoang, Giang Tra Tran, Dung Tran Ngoc, Duong Nguyen Dang, Dong Tran Van, Cuong Pham Hung, Tien Tran Dinh

    Background: The DynamX bioadaptor is a novel coronary implant with three helical strands that unlock and separate to provide dynamic vessel support restoring natural vessel function. Evidence in complex bifurcation lesions requiring planned two-stent strategies is limited. This analysis evaluated the feasibility and short-term outcomes of culotte bioadaptor implantation using intravascular ultrasound (IVUS). Methods: Thirteen consecutive patients underwent bifurcation percutaneous coronary intervention using culotte technique with DynamX bioadaptor between February and October 2025. All procedures followed a standardized culotte protocol with lesion preparation, proximal optimization technique, rewiring, and final kissing balloon inflation, with IVUS used to assess bioadaptor expansion, apposition, and structural integrity. Results: Technical and procedural success was achieved in all patients (100%), with successful rewiring through bioadaptor struts in all attempts (26 of 26, 100%). IVUS demonstrated satisfactory expansion: main branch ostial expansion 94.9% ± 10.6%, side branch ostial expansion 90.2% ± 17.5%, and proximal expansion ratio 0.95 ± 0.16. No strut fractures or malapposition occurred. Conclusions: Early experience with bioadaptor implantation in culotte bifurcation stenting demonstrates feasibility, with favorable acute IVUS findings in selected patients.


  • Comparative Evaluation of Transthoracic Echocardiography and Multislice Computed Tomography in the Preoperative Assessment of Tetralogy of Fallot

    by Van Hoang, Giang Tran Tra, Dong Tran Van, Duong Nguyen Dang, Dung Tran Ngoc

    Tetralogy of Fallot (TOF) is the most common cyanotic congenital heart disease, requiring precise anatomical assessment for optimal surgical planning. Transthoracic echocardiography (TTE) and multislice computed tomography (MSCT) are widely used imaging modalities for TOF evaluation, yet their relative diagnostic value, particularly in infants, remains an area of active investigation. This study aims to compare the diagnostic performance of TTE and MSCT in assessing intracardiac and extracardiac abnormalities in infants with TOF, with surgical findings as the reference standard. A prospective, single-center study was conducted on 35 infants diagnosed with TOF who underwent both TTE and 128-slice MSCT before surgical repair. Imaging findings were compared with intraoperative measurements, evaluating the sensitivity, specificity, and agreement (Cohen's kappa) between modalities. TTE and MSCT demonstrated comparable accuracy in assessing intracardiac abnormalities, with TTE showing slightly better agreement with surgical findings for ventricular septal defect (VSD) localization (κ = 0.581) than MSCT (κ = 0.485). Both modalities underestimated VSD size compared with intraoperative measurements, with MSCT showing a greater degree of underestimation (p < 0.001). In contrast, MSCT exhibited superior sensitivity in detecting extracardiac abnormalities, including coronary artery anomalies (100 vs. 50%) and major aortopulmonary collateral arteries (90 vs. 25%). While higher-generation MSCT scanners offer improved image resolution, the use of a 128-slice MSCT scanner proved to be a feasible alternative when more advanced technology is unavailable. TTE remains a reliable imaging modality for intracardiac assessment and is not inferior to MSCT in evaluating cardiac deformities in TOF. However, MSCT provides superior anatomical delineation of extracardiac structures, making it valuable for comprehensive preoperative planning. Despite its operator dependency, TTE remains the preferred first-line imaging tool due to its noninvasiveness and real-time functional assessment, whereas MSCT serves as a complementary modality, particularly for extracardiac evaluation. Further multicenter studies with larger cohorts are warranted to refine imaging protocols and optimize TOF assessment strategies in infants.