Toward miniaturized analysis of chemical identity and purity of radiopharmaceuticals via microchip electrophoresis
- 22 February 2018
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 410 (9) , 2423-2436
Abstract
Miniaturized synthesis of positron emission tomography (PET) tracers is poised to offer numerous advantages including reduced tracer production costs and increased availability of diverse tracers. While many steps of the tracer production process have been miniaturized, there has been relatively little development of microscale systems for the quality control (QC) testing process that is required by regulatory agencies to ensure purity, identity, and biological safety of the radiotracer before use in human subjects. Every batch must be tested, and in contrast with ordinary pharmaceuticals, the whole set of tests of radiopharmaceuticals must be completed within a short-period of time to minimize losses due to radioactive decay. By replacing conventional techniques with microscale analytical ones, it may be possible to significantly reduce instrument cost, conserve lab space, shorten analysis times, and streamline this aspect of PET tracer production. We focus in this work on miniaturizing the subset of QC tests for chemical identity and purity. These tests generally require high-resolution chromatographic separation prior to detection to enable the approach to be applied to many different tracers (and their impurities), and have not yet, to the best of our knowledge, been tackled in microfluidic systems. Toward this end, we previously explored the feasibility of using the technique of capillary electrophoresis (CE) as a replacement for the “gold standard” approach of using high-performance liquid chromatography (HPLC) since CE offers similar separating power, flexibility, and sensitivity, but can readily be implemented in a microchip format. Using a conventional CE system, we previously demonstrated the successful separation of non-radioactive version of a clinical PET tracer, 3′-deoxy-3′-fluorothymidine (FLT), from its known by-products, and the separation of the PET tracer 1-(2′-deoxy-2′-fluoro-β-D-arabinofuranosyl)-cytosine (D-FAC) from its α-isomer, with sensitivity nearly as good as HPLC. Building on this feasibility study, in this paper, we describe the first effort to miniaturize the chemical identity and purity tests by using microchip electrophoresis (MCE). The fully automated proof-of-concept system comprises a chip for sample injection, a separation capillary, and an optical detection chip. Using the same model compound (FLT and its known by-products), we demonstrate that samples can be injected, separated, and detected, and show the potential to match the performance of HPLC. Addition of a radiation detector in the future would enable analysis of radiochemical identity and purity in the same device. We envision that eventually this MCE method could be combined with other miniaturized QC tests into a compact integrated system for automated routine QC testing of radiopharmaceuticals in the future. Miniaturized quality control (QC) testing of batches of radiopharmaceuticals via microfluidic analysis. The proof-of-concept hybrid microchip electrophoresis (MCE) device demonstrated the feasibility of achieving comparable performance to conventional analytical instruments (HPLC or CE) for chemical purity testing.Keywords
Funding Information
- National Cancer Institute (U54 CA151819A)
- Biological and Environmental Research (DE-SC0001249)
- National Institute on Aging (R21AG049918)
This publication has 44 references indexed in Scilit:
- The Use ofF-FDG-PET/CT for Diagnosis and Treatment Monitoring of Inflammatory and Infectious DiseasesJournal of Immunology Research, 2013
- Simple preparation and purification of ethanol-free solutions of 3′-deoxy-3′-[18F]fluorothymidine by means of disposable solid-phase extraction cartridgesNuclear Medicine and Biology, 2012
- Hydrodynamic injection with pneumatic valving for microchip electrophoresis with total analyte utilizationElectrophoresis, 2011
- Sodium hydroxide treatment of PDMS based microfluidic devicesLab on a Chip, 2010
- A hybrid microdevice with a thin PDMS membrane on the detection window for UV absorbance detectionElectrophoresis, 2007
- Generation of Hydrophilic Poly(dimethylsiloxane) for High-Performance Microchip ElectrophoresisAnalytical Chemistry, 2006
- Design and Characterization of Poly(dimethylsiloxane)-Based Valves for Interfacing Continuous-Flow Sampling to Microchip ElectrophoresisAnalytical Chemistry, 2006
- Integrated Light Collimating System for Extended Optical-Path-Length Absorbance Detection in Microchip-Based Capillary ElectrophoresisAnalytical Chemistry, 2005
- Minimal dead-volume connectors for microfluidics using PDMS casting techniquesJournal of Micromechanics and Microengineering, 2004
- Microfluidic Devices Connected to Fused-Silica Capillaries with Minimal Dead VolumeAnalytical Chemistry, 1999