NHNoel Seunghyun Ha

Noel Seunghyun Ha

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Noel Seunghyun Ha has a total of 174 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers

    Biocatalytic cascades enable manufacture of the macrocyclic peptide enlicitide

    by Artis Klapars, Anna Fryszkowska, Stephanie Galanie, Omer Ad, Ellen Y. Aguilera, Nnamdi Akporji, Chihui An, Stephanus Axnanda, Tewoderos M. Ayele, Richard S. Ayikpoe, et al.

    Historically, many compelling therapeutic targets have been accessible only by injectable biologic drugs. Macrocyclic peptides, such as the proprotein convertase subtilisin/kexin type 9 inhibitor enlicitide for the treatment of atherosclerotic cardiovascular disease, are beginning to unlock these targets to orally administered therapies to enable broader patient access. We report the convergent biocatalytic assembly of enlicitide from simple building blocks enabled by a suite of engineered enzymes to catalyze selective peptide fragment formation, coupling, and macrocyclization in a protecting group–free manner. Together with efficient crystallizations that obviate the need for chromatography, this approach reduces the number of steps by greater than half compared with prior state-of-the-art methods, addressing long-standing synthetic challenges and offering a sustainable blueprint for the scalable development of complex peptide therapeutics.


  • A combinatorial droplet microfluidic device integrated with mass spectrometry for enzyme screening

    by Noel S. Ha, Jenny R. Onley, Kai Deng, Peter Andeer, Benjamin P. Bowen, Kshitiz Gupta, Peter W. Kim, Nathaniel Kuch, Mark Kutschke, Alex Parker, et al.

    We describe Drop-NIMS, a novel combination of droplet microfluidics and the matrix-free nanostructure-initiator mass spectrometry (NIMS) technology, with applications in enzyme screening.


  • Open Access

    Faster, better, and cheaper: harnessing microfluidics and mass spectrometry for biotechnology

    by Noel S. Ha, Markus de Raad, La Zhen Han, Amber Golini, Christopher J. Petzold, Trent R. Northen

    The integration of mass spectrometry with microfluidics has the potential to create high-throughput, sensitivity, and specificity assays.


  • Integration of High-Resolution Radiation Detector for Hybrid Microchip Electrophoresis

    by Jason Jones, Noel Seunghyun Ha, Alec G. Barajas, Arion F. Chatziioannou, R. Michael van Dam

    For decades, there has been immense progress in miniaturizing analytical methods based on electrophoresis to improve sensitivity, and to reduce sample volumes, separation times, and/or equipment cost and space requirements, in applications ranging from analysis of biological samples, to environmental analysis to forensics. In the field of radiochemistry, where radiation-shielded laboratory space is limited, there has been great interest in harnessing the compactness, high efficiency, and speed of microfluidics to synthesize short-lived radiolabeled compounds. We recently proposed that analysis of these compounds could also benefit from miniaturization, and have been investigating capillary electrophoresis (CE) and hybrid microchip electrophoresis (hybrid-MCE) as alternatives to the typically-used high-performance liquid chromatography (HPLC). We previously showed separation of the positron-emission tomography (PET) imaging tracer 3′-deoxy-3′-fluorothymidine (FLT) from its impurities in a hybrid-MCE device with UV detection, with similar separation performance to HPLC, but with improved speed and lower sample volumes. In this paper, we have developed an integrated radiation detector to enable measurement of the emitted radiation from radiolabeled compounds. Though conventional radiation detectors have been incorporated into CE systems in the past, these approaches cannot be readily integrated into a compact hybrid-MCE device. We instead employed a solid-state avalanche photodiode (APD)-based detector for real-time, high-sensitivity beta particle detection. The integrated system can reliably separate [18F]FLT from its impurities and perform chemical identification via co-injection with non-radioactive reference standard. This system can quantitate samples with radioactivity concentrations as low as 114 MBq/mL (3.1 mCi/mL), which is sufficient for analysis of radiochemical purity of radiopharmaceuticals.


  • Toward miniaturized analysis of chemical identity and purity of radiopharmaceuticals via microchip electrophoresis

    by Jimmy Ly, Noel S. Ha, Shilin Cheung, R. Michael van Dam

    Miniaturized synthesis of positron emission tomography (PET) tracers is poised to offer numerous advantages including reduced tracer production costs and increased availability of diverse tracers. While many steps of the tracer production process have been miniaturized, there has been relatively little development of microscale systems for the quality control (QC) testing process that is required by regulatory agencies to ensure purity, identity, and biological safety of the radiotracer before use in human subjects. Every batch must be tested, and in contrast with ordinary pharmaceuticals, the whole set of tests of radiopharmaceuticals must be completed within a short-period of time to minimize losses due to radioactive decay. By replacing conventional techniques with microscale analytical ones, it may be possible to significantly reduce instrument cost, conserve lab space, shorten analysis times, and streamline this aspect of PET tracer production. We focus in this work on miniaturizing the subset of QC tests for chemical identity and purity. These tests generally require high-resolution chromatographic separation prior to detection to enable the approach to be applied to many different tracers (and their impurities), and have not yet, to the best of our knowledge, been tackled in microfluidic systems. Toward this end, we previously explored the feasibility of using the technique of capillary electrophoresis (CE) as a replacement for the “gold standard” approach of using high-performance liquid chromatography (HPLC) since CE offers similar separating power, flexibility, and sensitivity, but can readily be implemented in a microchip format. Using a conventional CE system, we previously demonstrated the successful separation of non-radioactive version of a clinical PET tracer, 3′-deoxy-3′-fluorothymidine (FLT), from its known by-products, and the separation of the PET tracer 1-(2′-deoxy-2′-fluoro-β-D-arabinofuranosyl)-cytosine (D-FAC) from its α-isomer, with sensitivity nearly as good as HPLC. Building on this feasibility study, in this paper, we describe the first effort to miniaturize the chemical identity and purity tests by using microchip electrophoresis (MCE). The fully automated proof-of-concept system comprises a chip for sample injection, a separation capillary, and an optical detection chip. Using the same model compound (FLT and its known by-products), we demonstrate that samples can be injected, separated, and detected, and show the potential to match the performance of HPLC. Addition of a radiation detector in the future would enable analysis of radiochemical identity and purity in the same device. We envision that eventually this MCE method could be combined with other miniaturized QC tests into a compact integrated system for automated routine QC testing of radiopharmaceuticals in the future. Miniaturized quality control (QC) testing of batches of radiopharmaceuticals via microfluidic analysis. The proof-of-concept hybrid microchip electrophoresis (MCE) device demonstrated the feasibility of achieving comparable performance to conventional analytical instruments (HPLC or CE) for chemical purity testing.


  • Open Access

    Recent Progress toward Microfluidic Quality Control Testing of Radiopharmaceuticals

    by Noel S. Ha, Saman Sadeghi, R. Michael Van Dam

    Radiopharmaceuticals labeled with short-lived positron-emitting or gamma-emitting isotopes are injected into patients just prior to performing positron emission tomography (PET) or single photon emission tomography (SPECT) scans, respectively. These imaging modalities are widely used in clinical care, as well as in the development and evaluation of new therapies in clinical research. Prior to injection, these radiopharmaceuticals (tracers) must undergo quality control (QC) testing to ensure product purity, identity, and safety for human use. Quality tests can be broadly categorized as (i) pharmaceutical tests, needed to ensure molecular identity, physiological compatibility and that no microbiological, pyrogenic, chemical, or particulate contamination is present in the final preparation; and (ii) radioactive tests, needed to ensure proper dosing and that there are no radiochemical and radionuclidic impurities that could interfere with the biodistribution or imaging. Performing the required QC tests is cumbersome and time-consuming, and requires an array of expensive analytical chemistry equipment and significant dedicated lab space. Calibrations, day of use tests, and documentation create an additional burden. Furthermore, in contrast to ordinary pharmaceuticals, each batch of short-lived radiopharmaceuticals must be manufactured and tested within a short period of time to avoid significant losses due to radioactive decay. To meet these challenges, several efforts are underway to develop integrated QC testing instruments that automatically perform and document all of the required tests. More recently, microfluidic quality control systems have been gaining increasing attention due to vastly reduced sample and reagent consumption, shorter analysis times, higher detection sensitivity, increased multiplexing, and reduced instrumentation size. In this review, we describe each of the required QC tests and conventional testing methods, followed by a discussion of efforts to directly miniaturize the test or examples in the literature that could be implemented for miniaturized QC testing.


  • Production of diverse PET probes with limited resources: 24 18 F-labeled compounds prepared with a single radiosynthesizer

    by Jeffrey Collins, Christopher M. Waldmann, Christopher Drake, Roger Slavik, Noel S. Ha, Maxim Sergeev, Mark Lazari, Bin Shen, Frederick T. Chin, Melissa Moore, et al.

    Significance: Molecular imaging with PET can provide a dynamic, whole-body picture of the rate of biological processes or distribution of biological targets by tracking the distribution of radiolabeled molecules or particles in the body over time. Continual efforts to develop new PET probes are expanding the variety of processes and targets that can be visualized, facilitating basic research, drug development, and patient care. However, access to these probes at all stages of their development is hindered by high costs arising, in large part, from the significant resources that are typically dedicated to production of a single probe. Emerging technologies with increased synthesis flexibility are allowing increased probe diversity with fewer resources and could significantly increase access to new molecular imaging agents.


  • Novel volumetric method for highly repeatable injection in microchip electrophoresis

    by Noel S. Ha, Jimmy Ly, Jason Jones, Shilin Cheung, R. Michael van Dam