Influence of Electrode Configurations on the Interruption Capacity of Laser Triggered Vacuum Switch
- 27 April 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 48 (6) , 2180-2186
Abstract
The electrode configurations have an important effect on the interruption performances of laser triggered vacuum switch (LTVS), but few works pay attention to it so far. The objective of this article is to study the interruption capacity of LTVS with different electrode configurations. The 3-D simulation models of axial magnetic field (AMF) electrode and transverse magnetic field (TMF) electrode are built up, and the magnetic field distributions are calculated and compared. The test platform is set up based on a detachable vacuum chamber. The interruption capacity of LTVS with different electrode structures, electrode spacings, and polarity configurations is studied and analyzed. The test results prove that, compared to the AMF electrode, the interruption capacity of LTVS under the TMF electrode is obviously better, but it is more susceptible to the electrode spacing, and gradually decreases with the increase of electrode spacing. Influence of polarity configuration on the interruption capacity of LTVS is closely related to the target material. The LTVS with KCl + Ti under the positive polarity configuration shows better interruption capacity than negative polarity configuration. The works in this article provide references for the design of LTVS products.Keywords
Funding Information
- National Natural Science Foundation of China (51477024, 51777025)
- Fundamental Research Funds for the Central Universities (DUT19ZD219)
This publication has 9 references indexed in Scilit:
- Influences of Target Configurations on the Trigger Characteristics of Laser-Triggered Vacuum SwitchIEEE Transactions on Plasma Science, 2019
- Vacuum Arcs and Postarc Characteristic of Vacuum Interrupters With External AMF at Current ZeroIEEE Transactions on Plasma Science, 2018
- Influence of bias magnetic field on the vacuum arc in double‐break vacuum circuit breakersContributions to Plasma Physics, 2018
- Research on the Interaction of Primary Plasma and Main Electrode for Laser Triggered Vacuum SwitchIEEE Transactions on Plasma Science, 2014
- Initial Plasma Development of Field-Breakdown Triggered Vacuum SwitchIEEE Transactions on Plasma Science, 2010
- Operational Characteristics of a Field-Breakdown Triggered Vacuum SwitchIEEE Transactions on Magnetics, 2009
- Effects of electrode materials for arc-firing probability and switching time in UV-laser triggered vacuum gap1999
- A model for the operation of a laser-triggered vacuum low-inductance switchIEEE Transactions on Plasma Science, 1989
- Low-jitter laser-triggered vacuum switch using a composite targetIEEE Transactions on Plasma Science, 1988