Zhanqing Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zhanqing Chen has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Minfu Liao
School of Electrical Engineering, Dalian University of Technology, Dalian 116024, China
5 shared publications Xiongying Duan
5 shared publications- Zhipeng Lei
College of Electrical and Power Engineering, Taiyuan University of Technology, Taiyuan 030024, China
4 shared publications Ailiang Kang
3 shared publicationsBangfa Peng
3 shared publicationsJiyan Zou
School of Electrical Engineering, Dalian University of Technology, Dalian, China
3 shared publications
Latest Publications
- 2 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (4) , 1930-1939
Dynamic Behavior of Condensation and Its Influence on Properties of Epoxy Resin Insulation
In high-humidity environments, condensation can adhere to the surface of the epoxy resin, resulting in partial discharge or even flashover along the surface. To solve the deterioration of the insulation properties of epoxy resin caused by condensation discharge, the morphological change and flashover process of water droplets under different voltage waveforms are studied, the effects of water droplets on the electric field strength and electron density of the insulation surface are simulated, and the surface conductivity of the epoxy resin, Fourier transform infrared spectrum and microscopic morphology after condensation discharge are analyzed. The results show that the morphology of water droplets is closely related to the type and strength of the applied electric field. The flashover occurs along the surface of water droplets, which causes electrical tracking corrosion on the insulation surface, decomposes epoxy resin to form hydroxyl and carboxyl groups, and increases the surface conductivity. The maximum field strength is located at the junction of epoxy resin, the water droplet, and air. The damage under the impulse voltage is weaker than that under the sinusoidal voltage and the direct current voltage. The distortion of the electric field distribution and the electron accumulation on the epoxy resin surface result from the water droplets and their deformation, which accelerate the flashover and further lead to irreversible deterioration of epoxy resin.
- 2 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (4) , 1930-1939
Dynamic Behavior of Condensation and Its Influence on Properties of Epoxy Resin Insulation
In high-humidity environments, condensation can adhere to the surface of the epoxy resin, resulting in partial discharge or even flashover along the surface. To solve the deterioration of the insulation properties of epoxy resin caused by condensation discharge, the morphological change and flashover process of water droplets under different voltage waveforms are studied, the effects of water droplets on the electric field strength and electron density of the insulation surface are simulated, and the surface conductivity of the epoxy resin, Fourier transform infrared spectrum and microscopic morphology after condensation discharge are analyzed. The results show that the morphology of water droplets is closely related to the type and strength of the applied electric field. The flashover occurs along the surface of water droplets, which causes electrical tracking corrosion on the insulation surface, decomposes epoxy resin to form hydroxyl and carboxyl groups, and increases the surface conductivity. The maximum field strength is located at the junction of epoxy resin, the water droplet, and air. The damage under the impulse voltage is weaker than that under the sinusoidal voltage and the direct current voltage. The distortion of the electric field distribution and the electron accumulation on the epoxy resin surface result from the water droplets and their deformation, which accelerate the flashover and further lead to irreversible deterioration of epoxy resin.
- 30 September 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (14)
A coplanar-volume coupled discharge based on pre-ionization: Physical and chemical properties
A coplanar-volume coupled discharge utilizing a capillary coplanar dielectric barrier discharge (CDBD) as a pre-ionization source and employing a negative direct current (DC) voltage to prompt plasma propagation from the dielectric surface to the air gap is proposed and experimentally investigated. Optical-electrical properties, spatial-temporal evolution of plasma, and active species generation are systematically studied to provide in-depth insights into the plasma characteristics of coplanar-volume coupled discharge based on pre-ionization. Compared to traditional dielectric barrier discharge, this approach reduces the inception voltage and significantly enhances the discharge intensity. Spatial-temporal evolution of plasma morphology demonstrates two distinct discharge processes occurring in coplanar-volume coupled discharge: coupled primary discharge and coupled secondary discharge. These processes are developed from the coplanar primary discharge and coplanar secondary discharge in capillary CDBD, respectively. Through analyzing the effects of pulse voltage and negative DC voltage on the physical and chemical properties of plasma, coplanar-volume coupled discharge based on high pre-ionization exhibits strong plasma luminous intensity, elevated discharge energy, and heightened chemical activity.
- 30 September 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (14)
A coplanar-volume coupled discharge based on pre-ionization: Physical and chemical properties
A coplanar-volume coupled discharge utilizing a capillary coplanar dielectric barrier discharge (CDBD) as a pre-ionization source and employing a negative direct current (DC) voltage to prompt plasma propagation from the dielectric surface to the air gap is proposed and experimentally investigated. Optical-electrical properties, spatial-temporal evolution of plasma, and active species generation are systematically studied to provide in-depth insights into the plasma characteristics of coplanar-volume coupled discharge based on pre-ionization. Compared to traditional dielectric barrier discharge, this approach reduces the inception voltage and significantly enhances the discharge intensity. Spatial-temporal evolution of plasma morphology demonstrates two distinct discharge processes occurring in coplanar-volume coupled discharge: coupled primary discharge and coupled secondary discharge. These processes are developed from the coplanar primary discharge and coplanar secondary discharge in capillary CDBD, respectively. Through analyzing the effects of pulse voltage and negative DC voltage on the physical and chemical properties of plasma, coplanar-volume coupled discharge based on high pre-ionization exhibits strong plasma luminous intensity, elevated discharge energy, and heightened chemical activity.
- 1 March 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (3)
Deicing and status characteristics of dual-side pulsed surface dielectric barrier discharge
The deicing process and its status characteristics of dual-side pulsed surface dielectric barrier discharge (SDBD) are studied via electro-optical diagnostics, thermal properties, and numerical simulation. Experimental results show that the dual-side pulsed SDBD can remove the glaze ice compared to the traditional pulsed SDBD under the applied pulse voltage of 8 kV and a pulse frequency of 1 kHz. The maximal temperature of dual-side pulsed SDBD reaches 39.5 °C under the discharge time of 800 s, while the maximal temperature of traditional pulsed SDBD is still below ice point about −7.8 °C. Surface temperatures of dual-side pulsed SDBD demonstrate that the SDBD with a gap of 1 mm possesses prospects in deicing. The maximal surface temperature reaches 37.1 °C under the pulse of 8 kV after the discharge time of 90 s. Focusing on the thermal effect, a two-dimensional plasma fluid model is implemented, and the results also indicate that the dual-side pulsed SDBD with a gap of 1 mm produces a highest heat density among the three different configurations. Comparing the spatial-temporal evolutions of plasma on both dielectric sides, primary positive streamer has a longer propagation length of 8.6 mm than the secondary negative streamer, the primary negative streamer, and the secondary positive streamer, which induces a long heat covered area. Four stages of deicing process are analyzed through a series of electrical parameters under different covered ice conditions.
- 1 March 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (3)
Deicing and status characteristics of dual-side pulsed surface dielectric barrier discharge
The deicing process and its status characteristics of dual-side pulsed surface dielectric barrier discharge (SDBD) are studied via electro-optical diagnostics, thermal properties, and numerical simulation. Experimental results show that the dual-side pulsed SDBD can remove the glaze ice compared to the traditional pulsed SDBD under the applied pulse voltage of 8 kV and a pulse frequency of 1 kHz. The maximal temperature of dual-side pulsed SDBD reaches 39.5 °C under the discharge time of 800 s, while the maximal temperature of traditional pulsed SDBD is still below ice point about −7.8 °C. Surface temperatures of dual-side pulsed SDBD demonstrate that the SDBD with a gap of 1 mm possesses prospects in deicing. The maximal surface temperature reaches 37.1 °C under the pulse of 8 kV after the discharge time of 90 s. Focusing on the thermal effect, a two-dimensional plasma fluid model is implemented, and the results also indicate that the dual-side pulsed SDBD with a gap of 1 mm produces a highest heat density among the three different configurations. Comparing the spatial-temporal evolutions of plasma on both dielectric sides, primary positive streamer has a longer propagation length of 8.6 mm than the secondary negative streamer, the primary negative streamer, and the secondary positive streamer, which induces a long heat covered area. Four stages of deicing process are analyzed through a series of electrical parameters under different covered ice conditions.
- 29 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 50 (1) , 116-123
Influence of Trigger Pulse on the Trigger Characteristics of Surface Flashover Trigger Vacuum Switch
Surface flashover triggered vacuum switch (STVS) working performance mainly depends on the electrical characteristics of trigger pulse. This article presents an experimental investigation of the trigger process. The influence of the electrical properties of the trigger pulse on the trigger characteristics is focused. Based on the self-developed high-performance STVS product, the experimental test platform was established. The experimental results show that a shorter delay time of STVS can be obtained by heightening trigger voltage. However, the effect of trigger voltage on time jitter is not obvious. The slight increase in trigger current has evident influence on trigger delay time. It also does not affect the stability of trigger delay. With the increase in trigger voltage rise rate, the trigger delay time and time jitter can be optimized. Finally, the long-term stability of STVS is discussed. After 300 trigger times, the delay time changes from about 140 ns to more than 150 ns and the jitter changes from about 5 ns to more than 10 ns. In the design of STVS products, it is recommended to adopt a trigger system with a fast rise rate of trigger voltage and trigger current.
- 29 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 50 (1) , 116-123
Influence of Trigger Pulse on the Trigger Characteristics of Surface Flashover Trigger Vacuum Switch
Surface flashover triggered vacuum switch (STVS) working performance mainly depends on the electrical characteristics of trigger pulse. This article presents an experimental investigation of the trigger process. The influence of the electrical properties of the trigger pulse on the trigger characteristics is focused. Based on the self-developed high-performance STVS product, the experimental test platform was established. The experimental results show that a shorter delay time of STVS can be obtained by heightening trigger voltage. However, the effect of trigger voltage on time jitter is not obvious. The slight increase in trigger current has evident influence on trigger delay time. It also does not affect the stability of trigger delay. With the increase in trigger voltage rise rate, the trigger delay time and time jitter can be optimized. Finally, the long-term stability of STVS is discussed. After 300 trigger times, the delay time changes from about 140 ns to more than 150 ns and the jitter changes from about 5 ns to more than 10 ns. In the design of STVS products, it is recommended to adopt a trigger system with a fast rise rate of trigger voltage and trigger current.
- 24 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 49 (4) , 1357-1362
Effect of Arcing Time on Voltage Distribution of Double-Break Vacuum Circuit Breaker During the Transient Recovery Voltage Rising Phase
Grading capacitors are required to balance the voltage distribution of the double-break vacuum circuit breaker. However, large grading capacitors increase the magnitude and duration of the reignition current. To reduce grading capacitors, a synthetic circuit with double vacuum breaks was set up to study the effects of arcing time on voltage distribution. The voltage distribution of the upper break decreases from 61% to 52% with arcing times of two breaks decreasing from 6.6 to 3.4 ms synchronously. The experimental results demonstrate that reducing the arcing times can balance the voltage distribution during the transient recovery voltage (TRV) rising phase. The unbalance of TRV distribution can be further improved by adopting appropriate arcing times in the two breaks with grading capacitors having a capacitance of 3000 pF.
- 24 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 49 (4) , 1357-1362
Effect of Arcing Time on Voltage Distribution of Double-Break Vacuum Circuit Breaker During the Transient Recovery Voltage Rising Phase
Grading capacitors are required to balance the voltage distribution of the double-break vacuum circuit breaker. However, large grading capacitors increase the magnitude and duration of the reignition current. To reduce grading capacitors, a synthetic circuit with double vacuum breaks was set up to study the effects of arcing time on voltage distribution. The voltage distribution of the upper break decreases from 61% to 52% with arcing times of two breaks decreasing from 6.6 to 3.4 ms synchronously. The experimental results demonstrate that reducing the arcing times can balance the voltage distribution during the transient recovery voltage (TRV) rising phase. The unbalance of TRV distribution can be further improved by adopting appropriate arcing times in the two breaks with grading capacitors having a capacitance of 3000 pF.
- Open Access
- 21 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 17222-17228
Effect of Magnetic Field on Different Opening Processes of Multi-Break Vacuum Gaps
Vacuum gap saturation of single break can be solved by multiple breaks in series. In different breaking processes, the unbalanced energy and charges injected into the breaks lead to unbalanced voltage distribution. The purpose of this paper was to compare the voltage distribution under the regulation of magnetic field in different opening process. The magnetic fields with 3 ms width were applied at the point 3 ms before current through zero. Comparing with no axial magnetic field, the voltage distribution unbalances deceased both in synchronous and asynchronous opening processes. Under the condition that the arcing time of high-voltage break remained at 6.6 ms and the magnitude of axial magnetic fields was 60 mT, voltage distributions of high-voltage break were approximately proportional to the arcing times of the low-voltage break from 3.4 ms to 6.6 ms. It demonstrated that axial magnetic fields could effectively improve the voltage distribution of multi-break vacuum circuit breakers in synchronous and asynchronous opening processes.
- 21 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 17222-17228
Open AccessEffect of Magnetic Field on Different Opening Processes of Multi-Break Vacuum Gaps
Vacuum gap saturation of single break can be solved by multiple breaks in series. In different breaking processes, the unbalanced energy and charges injected into the breaks lead to unbalanced voltage distribution. The purpose of this paper was to compare the voltage distribution under the regulation of magnetic field in different opening process. The magnetic fields with 3 ms width were applied at the point 3 ms before current through zero. Comparing with no axial magnetic field, the voltage distribution unbalances deceased both in synchronous and asynchronous opening processes. Under the condition that the arcing time of high-voltage break remained at 6.6 ms and the magnitude of axial magnetic fields was 60 mT, voltage distributions of high-voltage break were approximately proportional to the arcing times of the low-voltage break from 3.4 ms to 6.6 ms. It demonstrated that axial magnetic fields could effectively improve the voltage distribution of multi-break vacuum circuit breakers in synchronous and asynchronous opening processes.
- 27 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 48 (6) , 2180-2186
Influence of Electrode Configurations on the Interruption Capacity of Laser Triggered Vacuum Switch
The electrode configurations have an important effect on the interruption performances of laser triggered vacuum switch (LTVS), but few works pay attention to it so far. The objective of this article is to study the interruption capacity of LTVS with different electrode configurations. The 3-D simulation models of axial magnetic field (AMF) electrode and transverse magnetic field (TMF) electrode are built up, and the magnetic field distributions are calculated and compared. The test platform is set up based on a detachable vacuum chamber. The interruption capacity of LTVS with different electrode structures, electrode spacings, and polarity configurations is studied and analyzed. The test results prove that, compared to the AMF electrode, the interruption capacity of LTVS under the TMF electrode is obviously better, but it is more susceptible to the electrode spacing, and gradually decreases with the increase of electrode spacing. Influence of polarity configuration on the interruption capacity of LTVS is closely related to the target material. The LTVS with KCl + Ti under the positive polarity configuration shows better interruption capacity than negative polarity configuration. The works in this article provide references for the design of LTVS products.
- 27 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 48 (6) , 2180-2186
Influence of Electrode Configurations on the Interruption Capacity of Laser Triggered Vacuum Switch
The electrode configurations have an important effect on the interruption performances of laser triggered vacuum switch (LTVS), but few works pay attention to it so far. The objective of this article is to study the interruption capacity of LTVS with different electrode configurations. The 3-D simulation models of axial magnetic field (AMF) electrode and transverse magnetic field (TMF) electrode are built up, and the magnetic field distributions are calculated and compared. The test platform is set up based on a detachable vacuum chamber. The interruption capacity of LTVS with different electrode structures, electrode spacings, and polarity configurations is studied and analyzed. The test results prove that, compared to the AMF electrode, the interruption capacity of LTVS under the TMF electrode is obviously better, but it is more susceptible to the electrode spacing, and gradually decreases with the increase of electrode spacing. Influence of polarity configuration on the interruption capacity of LTVS is closely related to the target material. The LTVS with KCl + Ti under the positive polarity configuration shows better interruption capacity than negative polarity configuration. The works in this article provide references for the design of LTVS products.