Targeted and bilateral blood flow monitoring in middle cerebral artery using diffuse correlation spectroscopy
Preprint
Abstract
Objective: To develop and validate a dual-probe Diffuse Correlation Spectroscopy (DCS) system for non-invasive and simultaneous, monitoring of cerebral blood flow (CBF) in the bilateral Middle Cerebral Artery (MCA) territories, and expanding the utility of conventional DCS limited to cortical-volume-based CBF measurements to vessel-specific cerebral perfusion monitoring. Methods: A dual-probe DCS system was designed for non-invasive monitoring of MCA-specific perfusion. Probe placement and protocol optimization study has been performed using anatomical landmarks, motor and speech activation tasks in healthy volunteers. System stability and repeatability were further evaluated in a pilot cohort of 30 healthy (age, 25 ± 7 years) participants using optimized probe position and protocol. A bilateral MCA ischemic Lacunar Infract stroke case report also validated the feasibility of the system in clinical settings. Results: Measurements demonstrated superior sensitivity towards MCA-territory perfusion at targeted probe locations compared to off-MCA positions. In pilot cohort, significant increase of 30.34 ± 21.56% and 36.48 ± 21.22% in rCBF corresponding to hand squeeze and speech task respectively showed reproducible physiological responsiveness of the system (p << 0.001). Measurement done on a patient with bilateral MCA ischemic Lacunar Infract stroke showed a significant change of 30% during speech for both the MCAs but no significant change is observed for hand squeeze tasks. Conclusion: The custom built dual-probe DCS system enables non-invasive, operator-independent, targeted and continuous monitoring of rCBF within bilateral MCA territories. Significance: This approach enables the potential use of DCS system for bilateral and vessel-specific monitoring of cerebral perfusion in the MCA territories.Keywords
Funding Information
- Technology Innovation Hub, Indian Institute of Technology Bombay
- Wadhwani Research Centre of Bioengineering, Indian Institute of Technology Bombay
- HDFC ERGO India (DO/2024-HDRD002-007)
- Core Research Grant, Science and Engineering Research Board (RD/0122-SERB000-049)
This publication has 21 references indexed in Scilit:
- Individualized autoregulation-guided arterial blood pressure management in neurocritical careNeurotherapeutics, 2025
- Global, regional, and national burden of stroke and its risk factors, 1990–2021: a systematic analysis for the Global Burden of Disease Study 2021The Lancet Neurology, 2024
- A comprehensive overview of diffuse correlation spectroscopy: Theoretical framework, recent advances in hardware, analysis, and applicationsNeuroImage, 2024
- Scoping Review of Clinical Practice Guidelines for the Early Management of Stroke with Focus on Endovascular TreatmentWorld Neurosurgery, 2021
- A fNIRS Investigation of Speech Planning and Execution in Adults Who StutterNeuroscience, 2019
- Gray's Anatomy, the Anatomical Basis of Clinical Practice, Forty‐First Edition, by SusanStandring, Editor‐in‐Chief,Elsevier Limited, 2016, 1,562 Pages, Hardcover, $228.99 ($171.74), ISBN: 978‐0‐7020‐5230‐9.Clinical Anatomy, 2016
- Diffuse correlation spectroscopy for non-invasive, micro-vascular cerebral blood flow measurementNeuroImage, 2014
- Correlation of Near-Infrared Spectroscopy and Transcranial Magnetic Stimulation of the Motor Cortex in Overt Reading and Musical TasksMotor Control, 2009
- Cerebral and systemic hemodynamic changes during cognitive and motor activation paradigmsAmerican Journal of Physiology-Regulatory, Integrative and Comparative Physiology, 2005
- N‐back working memory paradigm: A meta‐analysis of normative functional neuroimaging studiesHuman Brain Mapping, 2005