Hari M. Varma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hari M. Varma has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Murali Krishnamoorthy
Harvard Medical School
8 shared publications Soumyajit Sarkar
Department of Biosciences and Bioengineering, Indian Institute of Technology Bombay, Mumbai, India
6 shared publicationsMurali K
Department of Biosciences and Bioengineering, Indian Institute of Technology – Bombay (IITB), Mumbai, MH, India
5 shared publications- Susweta Das
Department of Biosciences and Bioengineering, Indian Institute of Technology Bombay, Mumbai, India
5 shared publications K Murali
Department of Bioscieneces and Bioengineering, Indian Institute of Technology - Bombay, Mumbai, India
3 shared publicationsRia Paul
Department of Biosciences and Bioengineering, Indian Institute of Technology Bombay, Mumbai, India
3 shared publications
Latest Publications
- Open Access
- 17 October 2026
- Published by Springer Nature in Communications Biology
Vascular tree structure-based perfusion phantom fabrication using modified Hele-Shaw cell method
- 17 October 2026
- Published by Springer Nature in Communications Biology
Open AccessVascular tree structure-based perfusion phantom fabrication using modified Hele-Shaw cell method
- Open Access
Targeted and bilateral blood flow monitoring in middle cerebral artery using diffuse correlation spectroscopy
Objective: To develop and validate a dual-probe Diffuse Correlation Spectroscopy (DCS) system for non-invasive and simultaneous, monitoring of cerebral blood flow (CBF) in the bilateral Middle Cerebral Artery (MCA) territories, and expanding the utility of conventional DCS limited to cortical-volume-based CBF measurements to vessel-specific cerebral perfusion monitoring. Methods: A dual-probe DCS system was designed for non-invasive monitoring of MCA-specific perfusion. Probe placement and protocol optimization study has been performed using anatomical landmarks, motor and speech activation tasks in healthy volunteers. System stability and repeatability were further evaluated in a pilot cohort of 30 healthy (age, 25 ± 7 years) participants using optimized probe position and protocol. A bilateral MCA ischemic Lacunar Infract stroke case report also validated the feasibility of the system in clinical settings. Results: Measurements demonstrated superior sensitivity towards MCA-territory perfusion at targeted probe locations compared to off-MCA positions. In pilot cohort, significant increase of 30.34 ± 21.56% and 36.48 ± 21.22% in rCBF corresponding to hand squeeze and speech task respectively showed reproducible physiological responsiveness of the system (p << 0.001). Measurement done on a patient with bilateral MCA ischemic Lacunar Infract stroke showed a significant change of 30% during speech for both the MCAs but no significant change is observed for hand squeeze tasks. Conclusion: The custom built dual-probe DCS system enables non-invasive, operator-independent, targeted and continuous monitoring of rCBF within bilateral MCA territories. Significance: This approach enables the potential use of DCS system for bilateral and vessel-specific monitoring of cerebral perfusion in the MCA territories.
Open AccessTargeted and bilateral blood flow monitoring in middle cerebral artery using diffuse correlation spectroscopy
Objective: To develop and validate a dual-probe Diffuse Correlation Spectroscopy (DCS) system for non-invasive and simultaneous, monitoring of cerebral blood flow (CBF) in the bilateral Middle Cerebral Artery (MCA) territories, and expanding the utility of conventional DCS limited to cortical-volume-based CBF measurements to vessel-specific cerebral perfusion monitoring. Methods: A dual-probe DCS system was designed for non-invasive monitoring of MCA-specific perfusion. Probe placement and protocol optimization study has been performed using anatomical landmarks, motor and speech activation tasks in healthy volunteers. System stability and repeatability were further evaluated in a pilot cohort of 30 healthy (age, 25 ± 7 years) participants using optimized probe position and protocol. A bilateral MCA ischemic Lacunar Infract stroke case report also validated the feasibility of the system in clinical settings. Results: Measurements demonstrated superior sensitivity towards MCA-territory perfusion at targeted probe locations compared to off-MCA positions. In pilot cohort, significant increase of 30.34 ± 21.56% and 36.48 ± 21.22% in rCBF corresponding to hand squeeze and speech task respectively showed reproducible physiological responsiveness of the system (p << 0.001). Measurement done on a patient with bilateral MCA ischemic Lacunar Infract stroke showed a significant change of 30% during speech for both the MCAs but no significant change is observed for hand squeeze tasks. Conclusion: The custom built dual-probe DCS system enables non-invasive, operator-independent, targeted and continuous monitoring of rCBF within bilateral MCA territories. Significance: This approach enables the potential use of DCS system for bilateral and vessel-specific monitoring of cerebral perfusion in the MCA territories.
- Open Access
Targeted measurement of blood flow in the Anterior Cerebral Artery using Diffuse Correlation Spectroscopy
Significance : Diffuse Correlation Spectroscopy (DCS) is an established technique for non-invasive monitoring of Cerebral Blood Flow (CBF), but existing applications primarily measure CBF changes averaged over cortical tissue volumes. A method capable of targeting blood flow within a particular intracranial artery would expand the utility of DCS for vessel-specific cerebral perfusion monitoring and continuous bedside assessment. Aim : We aim to investigate the feasibility of targeted, non-invasive monitoring of blood flow in the Anterior Cerebral Artery (ACA) using DCS through optimization of probe geometry and placement. Approach : A custom-built DCS system operating at 785 nm was used to probe ACA from the glabellar region. Source-detector (SD) separation, probe orientation, and probe location were systematically optimized using lower-limb motor tasks and a mental arithmetic task. The optimized configuration was evaluated using an ACA-mimicking multilayer phantom and validated in forty healthy volunteers during lower-limb activation tasks and postural changes. Results : An SD separation of 17 mm, vertical probe orientation, and glabellar placement provided the highest sensitivity to ACA-related blood flow changes. Phantom experiments demonstrated sensitivity to flow changes in a vessel located 45 mm beneath the scalp and showed that the frontal sinus, cerebrospinal fluid, and the absence of cortical tissue beneath the glabella along the longitudinal fissure together provide the best optical window for probing deep ACA flow. Using the optimized probe configuration, significant increases in relative CBF were observed during standing leg marching (66.4 +/- 38.6%) and supine leg crunches (39.4 +/- 32.2%) (p < 0.01), with consistent responses during supine-to-stand postural transitions. Conclusion : The proposed DCS approach enables targeted measurement of blood flow within the ACA territory. This technique provides a framework for continuous, non-invasive monitoring of ACA perfusion and has potential applications in cerebrovascular monitoring and stroke care.
Open AccessTargeted measurement of blood flow in the Anterior Cerebral Artery using Diffuse Correlation Spectroscopy
Significance : Diffuse Correlation Spectroscopy (DCS) is an established technique for non-invasive monitoring of Cerebral Blood Flow (CBF), but existing applications primarily measure CBF changes averaged over cortical tissue volumes. A method capable of targeting blood flow within a particular intracranial artery would expand the utility of DCS for vessel-specific cerebral perfusion monitoring and continuous bedside assessment. Aim : We aim to investigate the feasibility of targeted, non-invasive monitoring of blood flow in the Anterior Cerebral Artery (ACA) using DCS through optimization of probe geometry and placement. Approach : A custom-built DCS system operating at 785 nm was used to probe ACA from the glabellar region. Source-detector (SD) separation, probe orientation, and probe location were systematically optimized using lower-limb motor tasks and a mental arithmetic task. The optimized configuration was evaluated using an ACA-mimicking multilayer phantom and validated in forty healthy volunteers during lower-limb activation tasks and postural changes. Results : An SD separation of 17 mm, vertical probe orientation, and glabellar placement provided the highest sensitivity to ACA-related blood flow changes. Phantom experiments demonstrated sensitivity to flow changes in a vessel located 45 mm beneath the scalp and showed that the frontal sinus, cerebrospinal fluid, and the absence of cortical tissue beneath the glabella along the longitudinal fissure together provide the best optical window for probing deep ACA flow. Using the optimized probe configuration, significant increases in relative CBF were observed during standing leg marching (66.4 +/- 38.6%) and supine leg crunches (39.4 +/- 32.2%) (p < 0.01), with consistent responses during supine-to-stand postural transitions. Conclusion : The proposed DCS approach enables targeted measurement of blood flow within the ACA territory. This technique provides a framework for continuous, non-invasive monitoring of ACA perfusion and has potential applications in cerebrovascular monitoring and stroke care.
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 31 (4: Adv. in) , 1-11
Spatio-Temporal Simulation of Laser Speckles Using Stochastic Differential Equations
Laser speckle imaging modalities are receiving considerable attention for applications in both superficial and deep tissue imaging. This growing interest arises from their straightforward and cost-effective instrumentation, as well as the ease of computational implementation. Recent developments in this field require the calibration of devices, which often necessitates the simulation of dynamic laser speckles in tissue. Previous simulation models have predominantly relied on statistical tools such as copulas or Fourier transform methods based on diffraction theory. In our recent work, we introduced the use of Stochastic Differential Equations (SDEs) to model the temporal evolution of speckles, utilizing a predetermined probability density function and temporal autocorrelation. We further extended this simulation to create a calibrating phantom by inputting the stochastic time series data generated by SDEs into a piezo actuator. In the previous studies, the time evolution of each pixel was modeled independently using multiple SDEs. In the current work, we introduce a method for generating spatio-temporal dynamics of speckles characterized by predefined spatial and temporal correlation structures. This approach integrates SDE with Cholesky decomposition and inverse sampling method to achieve the desired spatial correlation profiles. The simulation results are obtained for practically feasible experimental parameters, effectively generating speckles that closely approximate the values observed in experimental settings.
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 31 (4: Adv. in) , 1-11
Spatio-Temporal Simulation of Laser Speckles Using Stochastic Differential Equations
Laser speckle imaging modalities are receiving considerable attention for applications in both superficial and deep tissue imaging. This growing interest arises from their straightforward and cost-effective instrumentation, as well as the ease of computational implementation. Recent developments in this field require the calibration of devices, which often necessitates the simulation of dynamic laser speckles in tissue. Previous simulation models have predominantly relied on statistical tools such as copulas or Fourier transform methods based on diffraction theory. In our recent work, we introduced the use of Stochastic Differential Equations (SDEs) to model the temporal evolution of speckles, utilizing a predetermined probability density function and temporal autocorrelation. We further extended this simulation to create a calibrating phantom by inputting the stochastic time series data generated by SDEs into a piezo actuator. In the previous studies, the time evolution of each pixel was modeled independently using multiple SDEs. In the current work, we introduce a method for generating spatio-temporal dynamics of speckles characterized by predefined spatial and temporal correlation structures. This approach integrates SDE with Cholesky decomposition and inverse sampling method to achieve the desired spatial correlation profiles. The simulation results are obtained for practically feasible experimental parameters, effectively generating speckles that closely approximate the values observed in experimental settings.
- Open Access
- 1 April 2025
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 12 (02) , 1-16
Optimized laser speckle–based imaging system and methods for deep tissue cerebral blood flow imaging in small rodents
SignificanceThe imaging of cerebral blood flow in small rodents is crucial for a better understanding of brain functions in healthy and diseased conditions. Existing methods often struggle to provide both superficial and deep tissue blood flow measurements in a non-invasive, flexible, and reliable manner, creating a need for an integrated platform that addresses these limitations.AimWe aim to design and develop a multi-modal laser speckle–based imaging platform and associated algorithms to image superficial and deep tissue cerebral blood flow in small rodents.ApproachA modular design has been adopted to integrate laser speckle contrast imaging and multi-speckle diffuse correlation tomography to a single cerebral blood flow imaging platform for small rodents with an independent module for animal holding and handling. A topographic imaging method, equipped with a filter to remove surface artifacts, was incorporated to image cerebral blood flow changes in response to forepaw and olfactory stimuli activations, with the skull and scalp kept intact.ResultsA significant increase in blood flow was found in the olfactory bulbs of mice post-stimulation by various odors (p<0.01). Similarly, forepaw stimulation resulted in a significant increase in blood flow in the contralateral side of the somatosensory cortex with the application of the filter for skull and scalp intact, skull intact, and skull removed cases (p<0.01).ConclusionsWe have validated our system through functional studies, demonstrating its capability to detect enhanced blood flow changes across the olfactory bulbs and somatosensory cortex in rodents with potential for broad applications in preclinical research.
- 1 April 2025
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 12 (02) , 1-16
Open AccessOptimized laser speckle–based imaging system and methods for deep tissue cerebral blood flow imaging in small rodents
SignificanceThe imaging of cerebral blood flow in small rodents is crucial for a better understanding of brain functions in healthy and diseased conditions. Existing methods often struggle to provide both superficial and deep tissue blood flow measurements in a non-invasive, flexible, and reliable manner, creating a need for an integrated platform that addresses these limitations.AimWe aim to design and develop a multi-modal laser speckle–based imaging platform and associated algorithms to image superficial and deep tissue cerebral blood flow in small rodents.ApproachA modular design has been adopted to integrate laser speckle contrast imaging and multi-speckle diffuse correlation tomography to a single cerebral blood flow imaging platform for small rodents with an independent module for animal holding and handling. A topographic imaging method, equipped with a filter to remove surface artifacts, was incorporated to image cerebral blood flow changes in response to forepaw and olfactory stimuli activations, with the skull and scalp kept intact.ResultsA significant increase in blood flow was found in the olfactory bulbs of mice post-stimulation by various odors (p<0.01). Similarly, forepaw stimulation resulted in a significant increase in blood flow in the contralateral side of the somatosensory cortex with the application of the filter for skull and scalp intact, skull intact, and skull removed cases (p<0.01).ConclusionsWe have validated our system through functional studies, demonstrating its capability to detect enhanced blood flow changes across the olfactory bulbs and somatosensory cortex in rodents with potential for broad applications in preclinical research.
- 18 July 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (8) , 4737-4748
Tunable dynamical tissue phantom for laser speckle imaging
We introduce a novel method to design and implement a tunable dynamical tissue phantom for laser speckle-based in-vivo blood flow imaging. This approach relies on stochastic differential equations (SDE) to control a piezoelectric actuator which, upon illuminated with a laser source, generates speckles of pre-defined probability density function and auto-correlation. The validation experiments show that the phantom can generate dynamic speckles that closely replicate both surfaces as well as deep tissue blood flow for a reasonably wide range and accuracy.
- 18 July 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (8) , 4737-4748
Tunable dynamical tissue phantom for laser speckle imaging
We introduce a novel method to design and implement a tunable dynamical tissue phantom for laser speckle-based in-vivo blood flow imaging. This approach relies on stochastic differential equations (SDE) to control a piezoelectric actuator which, upon illuminated with a laser source, generates speckles of pre-defined probability density function and auto-correlation. The validation experiments show that the phantom can generate dynamic speckles that closely replicate both surfaces as well as deep tissue blood flow for a reasonably wide range and accuracy.
- Open Access
Tunable dynamical tissue phantom for laser speckle imaging
We introduce a novel method to design and implement a tunable dynamical tissue phantom for laser speckle-based in-vivo blood flow imaging. This approach relies on Stochastic Differential Equations (SDE) to control a piezoelectric actuator which, upon illuminated with a laser source, generates speckles of pre-defined probability density function and auto-correlation. The validation experiments show that the phantom can generate dynamic speckles that closely replicate both surfaces as well as deep tissue blood flow for a reasonably wide range and accuracy.
Open AccessTunable dynamical tissue phantom for laser speckle imaging
We introduce a novel method to design and implement a tunable dynamical tissue phantom for laser speckle-based in-vivo blood flow imaging. This approach relies on Stochastic Differential Equations (SDE) to control a piezoelectric actuator which, upon illuminated with a laser source, generates speckles of pre-defined probability density function and auto-correlation. The validation experiments show that the phantom can generate dynamic speckles that closely replicate both surfaces as well as deep tissue blood flow for a reasonably wide range and accuracy.
- 1 January 2024
- Published by Optica Publishing Group
- p. JTu2A.200
A Stochastic optimization approach to laser speckle contrast imaging for a better estimation of blood flow
We have recently proposed the use of stochastic differential equations to simulate speckle intensity with pre-defined probability density function and auto-correlation for applications in imaging tissue blood flow. Here, we extend the above-mentioned model to compute better estimates of blood flow from speckle measurements using a stochastic optimization approach. We validate the method using simulations, tissue-mimicking flow phantoms, and in − vivo human experiments.
- 1 January 2024
- Published by Optica Publishing Group
- p. JTu2A.200
A Stochastic optimization approach to laser speckle contrast imaging for a better estimation of blood flow
We have recently proposed the use of stochastic differential equations to simulate speckle intensity with pre-defined probability density function and auto-correlation for applications in imaging tissue blood flow. Here, we extend the above-mentioned model to compute better estimates of blood flow from speckle measurements using a stochastic optimization approach. We validate the method using simulations, tissue-mimicking flow phantoms, and in − vivo human experiments.
- 30 November 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (12) , 6745-6762
Laser speckle simulation tool based on stochastic differential equations for bio imaging applications
Laser speckle-based blood flow imaging is a well-accepted and widely used method for pre-clinical and clinical applications. Although it was introduced as a method to measure only superficial blood flow (< 1mm depth), several recently introduced variants resulted in measuring deep tissue blood flow (a few cm) as well. A means of simulating laser speckles is often necessary for the analysis and development of these imaging modalities, as evident from many such attempts towards developing simulation tools in the past. Such methods often employ Fourier transforms or statistical tools to simulate speckles with desired statistical properties. We present the first method to use a stochastic differential equation to generate laser speckles with a pre-determined probability density function and a temporal auto-correlation. The method allows the choice of apriori gamma distribution along with simple exponential or more complex temporal auto-correlation statistics for simulated speckles, making it suitable for different blood flow profiles. In contrast to the existing methods that often generate speckles associated with superficial flow, we simulate both superficial and diffuse speckles leading to applications in deep tissue blood flow imaging. In addition, we have also incorporated appropriate models for noise associated with the detectors to simulate realistic speckles. We have validated our model by comparing the simulated speckles with those obtained from in-vivo studies in mice and healthy human subject.
- 30 November 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (12) , 6745-6762
Laser speckle simulation tool based on stochastic differential equations for bio imaging applications
Laser speckle-based blood flow imaging is a well-accepted and widely used method for pre-clinical and clinical applications. Although it was introduced as a method to measure only superficial blood flow (< 1mm depth), several recently introduced variants resulted in measuring deep tissue blood flow (a few cm) as well. A means of simulating laser speckles is often necessary for the analysis and development of these imaging modalities, as evident from many such attempts towards developing simulation tools in the past. Such methods often employ Fourier transforms or statistical tools to simulate speckles with desired statistical properties. We present the first method to use a stochastic differential equation to generate laser speckles with a pre-determined probability density function and a temporal auto-correlation. The method allows the choice of apriori gamma distribution along with simple exponential or more complex temporal auto-correlation statistics for simulated speckles, making it suitable for different blood flow profiles. In contrast to the existing methods that often generate speckles associated with superficial flow, we simulate both superficial and diffuse speckles leading to applications in deep tissue blood flow imaging. In addition, we have also incorporated appropriate models for noise associated with the detectors to simulate realistic speckles. We have validated our model by comparing the simulated speckles with those obtained from in-vivo studies in mice and healthy human subject.
- 28 October 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (11) , 6081-6099
High-density diffuse correlation tomography with enhanced depth localization and minimal surface artefacts
A spatially weighted filter applied to both the measurement and the Jacobian is proposed for high-density diffuse correlation tomography (DCT) to remove unwanted extracerebral interferences and artefacts along with better depth localization in the reconstructed blood flow images. High-density DCT is implemented by appropriate modification of recently introduced Multi-speckle Diffuse Correlation Spectroscopy (M-DCS) system. Additionally, we have used autocorrelation measurements at multiple delay-times in an iterative manner to improve the reconstruction results. The proposed scheme has been validated by simulations, phantom experiments and in-vivo human experiments.
- 28 October 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (11) , 6081-6099
High-density diffuse correlation tomography with enhanced depth localization and minimal surface artefacts
A spatially weighted filter applied to both the measurement and the Jacobian is proposed for high-density diffuse correlation tomography (DCT) to remove unwanted extracerebral interferences and artefacts along with better depth localization in the reconstructed blood flow images. High-density DCT is implemented by appropriate modification of recently introduced Multi-speckle Diffuse Correlation Spectroscopy (M-DCS) system. Additionally, we have used autocorrelation measurements at multiple delay-times in an iterative manner to improve the reconstruction results. The proposed scheme has been validated by simulations, phantom experiments and in-vivo human experiments.