A Fiber-Tip Laminar Flow Rate Sensor With Temperature Compensated Based on Three-Beam Interferometer
- 18 December 2024
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 43 (7) , 3316-3324
Abstract
The widespread utilization of microfluidics has increased the demand for flow rate precisely sensing in channel. In this paper, we propose a fiber-tip laminar flow rate sensor with temperature compensated based on three-beam interferometer, which is composed by a piece of polydimethylsiloxane (PDMS) and air in a section of hollow core fiber (HCF) sealed by graphene oxide (GO) film. Fluid with different flow rate will cause different impacts on the GO film, causing changes of the length of the air cavity. PDMS in the bottom of the cavity serves as a temperature-compensated portion because of the high thermo-optical coefficient (TOC) for testing the flow rate of microfluidics with different temperatures. The change of the length of the air cavity and the refractive index (RI) of the PDMS both will cause the shifting of the interference dips in the spectrum of the flow rate sensor. The ultra-thin GO film indicates that the sensor has a high-rate sensitivity, which can be used for the laminar flow rate measuring. The flow rate sensitivity can reach −44.679 nm/(mL/min) in the range of 0.01 to 0.1 mL/min. The actual flow field rate in the channel is obtained because the influence of the probe sensor embedding on the flow rate field is compensated during the calibration process. In addition, the sensor demonstrates a high-temperature compensated sensitivity of 30.963 nm/°C. This work provides a compact all-optical solution for laminar flow rate monitoring, which can also be applied to flow rate measuring in drug delivery, blood osmometry and bioanalysis.Keywords
Funding Information
- National Natural Science Foundation of China (62375058, 62405069, 62475060)
- China Postdoctoral Science Foundation (2024MD753925)
- Scientific Research and Technology Development Program of Guangxi Zhuang Autonomous Region (AD23026118)
- Natural Science Foundation of Guangxi Province (2021GXNSFAA220057, 2024GXNSFAA010428)
- Guangxi Key Laboratory of Optoelectroric Information Processing (GD22102, GD23103)
- 2024 Guangxi Young and middle-aged teachers research basic ability improvement project (2024KY0225, 2023KY0199)
This publication has 34 references indexed in Scilit:
- Experimental Measurement of Enhanced and Hindered Particle Settling in Turbulent Gas‐Particle Suspensions, and Geophysical ImplicationsJournal of Geophysical Research: Solid Earth, 2023
- Multiparameter measuring system using fiber optic sensors for hydraulic temperature, pressure and flow monitoringMeasurement, 2022
- A hot-wire flowmeter based on fiber Extrinsic Fabry–Pérot Interferometer with assistance of fiber Bragg gratingOptics Communications, 2021
- Air pressure measurement of circular thin plate using optical fiber multimode interferometerMeasurement, 2021
- Flow quantification in congenital heart disease with magnetic resonance imaging: A new tool in multimodality assessment of complex abnormalitiesArchives of Cardiovascular Diseases, 2020
- Cascaded bowknot-type taper based Mach–Zehnder interferometer for microfluidic flow rate sensingOptical Fiber Technology, 2019
- Monitoring water seepage velocity in dikes using distributed optical fiber temperature sensorsAutomation in Construction, 2017
- Theory and structure of a modified optical fiber turbine flowmeterFlow Measurement and Instrumentation, 2016
- Erratum to: Fetal blood flow velocimetry by phase-contrast MRI using a new triggering method and comparison with Doppler ultrasound in a sheep model: a pilot studyMagnetic Resonance Materials in Physics, Biology and Medicine, 2013
- A self-bended piezoresistive microcantilever flow sensor for low flow rate measurementSensors and Actuators A: Physical, 2010