YLYi Liu

Yi Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yi Liu has a total of 91 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Highly Sensitive Microdisplacement Sensor Based on Sidewall Resonance Effect of Optical Fiber Liquid Cladding

    by An Xia, Yi Zhang, Jinjian Li, Wenxue Li, Yi Liu, Jingfu Ye, Weijiang Xu, Shiliang Qu

    Optical fiber displacement sensors are extensively used in pre-warning of landslide and earthquake. Here, we propose a highly sensitive micro-displacement sensor based on side-wall (SR) resonance effect of optical fiber liquid cladding. The sensor structure has two single-mode fibers (SMF) fused at both ends of a no-core fiber (NCF), placed in a glass capillary filled with cedar oil. The effective refractive index (RI) of the cedar oil can be matched with the RI of optical fiber, which is conducive to the SR effect. The micro-displacement of the monitored object will cause the bending of the sensing structure, resulting in a change in the thickness of the liquid cladding and the shifting of the SR dips in output spectrum. Besides, we introduce a piece of tapered no-core fiber (TNCF) into the original structure. Experimental results demonstrate that the displacement sensitivity of improved structure is increased from 5.02 nm/μm to 9.02 nm/μm, compared to the sensor with NCF, while the compensated temperature sensitivity is increased from –3.69 nm/°C to –13.76 nm/°C. Due to the excellent performance of the micro-displacement sensing structure based on SR effect of optical fiber liquid cladding, it offers broad prospects for applications such as monitoring earthquake waves and building frame.


  • Controllable and Flexible 4D Fabrication Strategy for Expandable Micro-Sensor Elements on the Fiber

    by Chang-Xu Li, Qiao-Ling Chen, Xi-Lin Li, Jian Qu, Yi Liu, Shi-Liang Qu

    In the realm of high-precision integrated applications involving optical fiber sensor components and materials, conventional macro-processes such as fiber coating and tip dispensing lack precise control and flexibility. In this paper, a two-photon polymerization technique was employed to fabricate a microscopic F-P framework and a peripheral fence on the tip of a single-mode fiber. Subsequently, precision dispensing methods were utilized to introduce hydrogel into the fence. A concept of the “sensitization-fence” is introduced to enhance sensitivity. Finite element simulations revealed that as the height of the fence increased, the displacement of the F-P sensing cavity also increased, indicating heightened sensitivity. In the subsequent experimental exploration, acrylic acid hydrogels, PDMS, and polyvinyl alcohol were successively filled into the fence, and ideal experimental results were obtained. This proof of the sensitizing concept provides a new application idea for improving the function of micro-devices on the fiber.


  • A Fiber-Tip Laminar Flow Rate Sensor With Temperature Compensated Based on Three-Beam Interferometer

    by Wenxue Li, Jinjian Li, Jian Qu, Yi Zhang, Min Li, Jingfu Ye, Yi Liu, Shiliang Qu

    The widespread utilization of microfluidics has increased the demand for flow rate precisely sensing in channel. In this paper, we propose a fiber-tip laminar flow rate sensor with temperature compensated based on three-beam interferometer, which is composed by a piece of polydimethylsiloxane (PDMS) and air in a section of hollow core fiber (HCF) sealed by graphene oxide (GO) film. Fluid with different flow rate will cause different impacts on the GO film, causing changes of the length of the air cavity. PDMS in the bottom of the cavity serves as a temperature-compensated portion because of the high thermo-optical coefficient (TOC) for testing the flow rate of microfluidics with different temperatures. The change of the length of the air cavity and the refractive index (RI) of the PDMS both will cause the shifting of the interference dips in the spectrum of the flow rate sensor. The ultra-thin GO film indicates that the sensor has a high-rate sensitivity, which can be used for the laminar flow rate measuring. The flow rate sensitivity can reach −44.679 nm/(mL/min) in the range of 0.01 to 0.1 mL/min. The actual flow field rate in the channel is obtained because the influence of the probe sensor embedding on the flow rate field is compensated during the calibration process. In addition, the sensor demonstrates a high-temperature compensated sensitivity of 30.963 nm/°C. This work provides a compact all-optical solution for laminar flow rate monitoring, which can also be applied to flow rate measuring in drug delivery, blood osmometry and bioanalysis.


  • Open Access

    High‐fidelity optical fiber microphone based on graphene oxide and Au nanocoating

    by Liangtao Hou, Yan Li, Libin Sun, Chao Liu, Yichao Zheng, Yi Liu, Shiliang Qu

    A high‐fidelity optical fiber microphone (HF‐OFM) with hybrid frequency and fast response is theoretically and experimentally demonstrated by the nanofabrication techniques for real‐time communication, which consists of a graphene oxide (GO) film, an Au nanocoating, and an air cavity. The internal stress of the film is increased by the method of mechanical tensile preparation, and the microphone response flatness is improved. Meanwhile, the structural design of the 3 nm Au nanocoating improves the acoustic pressure detection sensitivity by 2.5 times by increasing the reflectivity. The experimental result shows that single, dual, and triple frequency acoustic signal detection in the frequency range of 0.1 kHz–20 kHz are achieved with acoustic pressure sensitivities of 9.64, 9.66, and 8.9 V/Pa, as well as flat frequency response (1/2 . In addition, the high‐fidelity real‐time transmission of audio signals over an angle range of −90° to 90° is verified by a self‐made acoustic pressure detection device. Such a compact, high sensitivity, and large measurement range HF‐OFM is very promising for applications of oil leakage exploration, acoustic source location, and real‐time communication.


  • Open Access

    Microfluidic Chip with Fiber-Tip Sensors for Synchronously Monitoring Concentration and Temperature of Glucose Solutions

    by Jian Qu, Yi Liu, Yan Li, Jinjian Li, Songhe Meng

    Monitoring the properties of fluids in microfluidic chips often requires complex open-space optics technology and expensive equipment. In this work, we introduce dual-parameter optical sensors with fiber tips into the microfluidic chip. Multiple sensors were distributed in each channel of the chip, which enabled the real-time monitoring of the concentration and temperature of the microfluidics. The temperature sensitivity and glucose concentration sensitivity could reach 314 pm/°C and −0.678 dB/(g/L), respectively. The hemispherical probe hardly affected the microfluidic flow field. The integrated technology combined the optical fiber sensor with the microfluidic chip and was low cost with high performance. Therefore, we believe that the proposed microfluidic chip integrated with the optical sensor is beneficial for drug discovery, pathological research and material science investigation. The integrated technology has great application potential for micro total analysis systems (μ-TAS).


  • Ultra-Sensitive Temperature Sensor of Cascaded Dual PDMS-Cavity Based on Enhanced Vernier Effect

    by Jinjin Liang, Jian Qu, Jingfu Ye, Yi Liu, Shiliang Qu

    In this paper, an ultra-sensitive temperature sensor based on enhanced vernier effect is presented. It consists of a double-groove cavity (DGC) and an open cavity (OC) filled with polydimethylsiloxane (PDMS). The length of DGC is limited by two single-mode fibers (SMF), and the length of OC is not limited. The two sensing cavities are affected by the thermal optic effect (TOE) and thermal expansion effect (TEE). Their interference dip of the spectra shifts to the opposite directions respectively, which realizes the enhanced vernier effect. The sensitivity of the sensor can be further improved, and the interference caused by the reference cavity can be also eliminated. The experimental results show that the sensor exhibits a high temperature sensitivity of 11.93 nm/°C. Compared to the traditional sensors based on vernier effect using TOE (3.33 nm/°C) or TEE (8.62 nm/°C) alone, the sensitivity increased by 264.8 % and 38.4 % respectively. As such, we believe that the proposed sensor has great application potential in biochemical detection, aeronautical engineering and environmental monitoring.


  • Highly Sensitive Curvature and Temperature Sensor Based on Double Groove Structure and Hollow Core Fiber

    by Xin Li, Jinjin Liang, Jinjian Li, Jingfu Ye, Yi Liu, Ming Chen, Zhenrong Zhang, Shiliang Qu

    In this paper, we propose a curvature and temperature sensor based on two symmetrical grooves and a hollow core fiber (HCF) filled with polydimethylsiloxane (PDMS). The two grooves are produced by splicing both ends of the polished HCF with two multimode fibers (MMFs). The proposed groove structure is sensitive to curvature, and the PDMS, with a high thermo-optical coefficient, makes the sensor highly sensitive to temperature. The experimental results show that the sensor exhibits a high sensitivity of −6.833 nm/m −1 in the curvature range of 0 m −1 to 45.97m −1 , and a high sensitivity of 4.278 nm/°C in the temperature range of 25°C to 95°C. The proposed sensor can monitor curvature and temperature simultaneously in real-time, and has potential application prospects in industrial production, biomedicine, structural health monitoring, and other fields.


  • An Ultra-Simple Microchannel-Free Fiber-Optic Gas-Pressure Sensor With Ultra-Fast Response

    by Yi Liu, Jinjian Li, Ming Chen, Shiliang Qu

    An ultra-simple microchannel-free fiber-optic gas-pressure sensor based on a section of quartz capillary is proposed. The resonance peaks and interference fringes can be both shown in the reflection spectrum and they are both sensitive to the variation of the gas refractive index and temperature. The gas-pressure can be demodulated by using sensing matrix. As the quartz capillary is open completely at its end, the pressure response time is reduced to 0.02s for the pressure variation of 0.1MPa. The proposed sensor can have actual applications in 24-hour gas-pressure monitoring and early warning in harsh environment, because of its ultra-simple and all-silica structure, ultra-fast response, good repeatability, and ultra-low fabrication cost.


  • Open Access

    On-Chip Optical Vortex Generation and Topological Charge Control by Methods of Wave Vector Manipulation

    by Jingfu Ye, Yan Li, Yi Liu, Shiliang Qu

    Optical vortices (OVs) have received much attention in recent years and are widely explored in communication applications. The on-chip vortex emitter/modulator is preferred when it comes to photonic integration and chip-scale communication. However, the existing emitters/modulators suffer from either narrow bandwidths or extensibility problems, which actually degrade their ability to improve communication capacity. Here, we propose a metasurface OV emitter based on wave vector synthesis for vortex generation and modulation. A thorough theoretical analysis of the OV generation by two approximate methods was carried out, which suggests the superiority of Wave Vector method over Phase method. Afterwards, the wave vector manipulation implemented by Phase gradient metasurfaces was studied for controlling the topological charges of generated OVs. Finite element method simulations showed that, in the topological charge range of −6 to 6 and the wavelength range of 1.45 μm to 1.55 μm, the effective vortex emission efficiency of the proposed emitter is around 45%. The on-chip vortex generation and control by wave vector manipulation is a very promising technology for high-capacity inter-chip optical communication.


  • Ultra-Sensitive Optical Fiber Humidity Sensor via Au-Film-Assisted Polyvinyl Alcohol Micro-Cavity and Vernier Effect

    by Liangtao Hou, Yan Li, Yiming Fu, Jiuru Yang, Weijiang Xu, Xiaokang Song, Jinjian Li, Yi Liu, Lingling Ran

    To enhance humidity sensitivity, a parallel Fabry–Perot interferometer (FPI)-based Vernier scheme is theoretically and experimentally developed via the parallel and separated micro-cavities of polyvinyl alcohol (PVA) and hollow core fiber (HCF). Through Au-film assistance and fine attenuation adjustment, the matched light energy of micro-cavities is obtained and high-contrast envelope with ~11-fold improvement is demonstrated within the 200-nm range. Centering the $\sim 77~\mu \text{m}$ length Au-PVA micro-cavity, the comprehensive tests in terms of humidity are conducted. The experimental results show that, owing to the magnification of Vernier effect, ultra-sensitive humidity response of −9.14 nm/%RH is gained. And the crosstalk of temperature is constrained within −0.0843%RH/°C. In addition, 0.505 s dynamic time-response is verified through field tests of breathing. With the merits of stability, compact size, and ease of operation, our scheme is very practical and has potential in the applications of humidity-related biochemical sensing and medical health monitoring.