Diffusion tensor imaging and arterial tissue: establishing the influence of arterial tissue microstructure on fractional anisotropy, mean diffusivity and tractography
Open Access
- 26 November 2020
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-12
Abstract
This study investigates diffusion tensor imaging (DTI) for providing microstructural insight into changes in arterial tissue by exploring how cell, collagen and elastin content effect fractional anisotropy (FA), mean diffusivity (MD) and tractography. Five ex vivo porcine carotid artery models (n = 6 each) were compared—native, fixed native, collagen degraded, elastin degraded and decellularised. Vessels were imaged at 7 T using a DTI protocol with b = 0 and 800 s/mm2and 10 isotopically distributed directions. FA and MD were evaluated in the vessel media and compared across models. FA values measured in native (p < 0.0001), fixed native (p < 0.0001) and collagen degraded (p = 0.0018, p = 0.0016, respectively) were significantly higher than those in elastin degraded and decellularised arteries. Native and fixed native had significantly lower MD values than elastin degraded (p < 0.0001) and decellularised tissue (p = 0.0032, p = 0.0003, respectively). Significantly lower MD was measured in collagen degraded compared with the elastin degraded model (p = 0.0001). Tractography yielded helically arranged tracts for native and collagen degraded vessels only. FA, MD and tractography were found to be highly sensitive to changes in the microstructural composition of arterial tissue, specifically pointing to cell, not collagen, content as the dominant source of the measured anisotropy in the vessel wall.Keywords
All Related Versions
Funding Information
- European Research Council (Grant Agreement No. 637674)
This publication has 76 references indexed in Scilit:
- Fibre orientation of fresh and frozen porcine aorta determined non-invasively using diffusion tensor imagingMedical Engineering & Physics, 2012
- Effect of motion on the ADC quantification accuracy of whole-body DWIBSMagnetic Resonance Materials in Physics, Biology and Medicine, 2012
- Effects of intima stiffness and plaque morphology on peak cap stressBioMedical Engineering OnLine, 2011
- The Basic Science of Articular Cartilage: Structure, Composition, and FunctionSports Health: A Multidisciplinary Approach, 2009
- Aldehyde fixative solutions alter the water relaxation and diffusion properties of nervous tissueMagnetic Resonance in Medicine, 2009
- The three-dimensional micro- and nanostructure of the aortic medial lamellar unit measured using 3D confocal and electron microscopy imaging☆Matrix Biology, 2008
- An Ultrastructural Analysis of Collagen in Tissue Engineered ArteriesAnnals of Biomedical Engineering, 2007
- The Effect of Fixation and Histological Preparation on Coronary Artery DimensionsAnnals of Biomedical Engineering, 2005
- Inflammation in atherosclerosisNature, 2002
- Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imagingMagnetic Resonance in Medicine, 1999