Characterisation of a Schottky ISFET as Hg-MOSFET and as cytochrome P450-ENFET
- 7 July 2018
- journal article
- research article
- Published by Taylor & Francis in International Journal of Electronics
- Vol. 105 (11) , 1855-1865
Abstract
A cost-effective and simple method is proposed wherein a Schottky ion sensitive field effect transistor (Schottky ISFET)-based sensor is characterised as metal oxide semiconductor and enzyme field effect transistor (ENFET). This technique involves deposition of mercury (Hg) as gate material over the sensing layer mitigating the complexity of fabrication process, thereby eliminating the need of refabricating an identical device. A Schottky-based ISFET simplifies the fabrication process as the requisite for doping of source and drain regions becomes redundant. Steps involved in lithography process for fabricating metal oxide semiconductor field effect transistor (MOSFET) are reduced with the use of liquid metal Hg as gate over layer. Such a device can be transformed back to an ISFET without any additional etching process. Furthermore, the same ISFET device can be utilised as an ENFET when the former is used in conjunction with a biological element. In this work, a Schottky-based ISFET has been characterised as Hg-MOSFET and as cytochrome P450-ENFET. Multiple tests on the device exhibit that the same ISFET sensor can be used both as a MOSFET and an ENFET with good repeatability and versatility without losing its sensitivity.Keywords
This publication has 30 references indexed in Scilit:
- Design and development of a novel high-transconductance pH-ISFET (ion-sensitive field-effect transistor)-based glucose biosensorInternational Journal of Electronics, 2006
- Cytochrome P450 biosensors—a reviewBiosensors and Bioelectronics, 2005
- The Role of the Mercury-Si Schottky-Barrier Height in$Psi$-MOSFETsIEEE Transactions on Electron Devices, 2004
- Thirty years of ISFETOLOGYSensors and Actuators B: Chemical, 2003
- Schottky Barriers and the Reactivity of the InterfaceEurophysics Letters, 1994
- Urea sensor based on an ammonium-ion-sensitive field-effect transistorSensors and Actuators B: Chemical, 1991
- Glucose-sensitive field-effect transistor with a membrane containing co-immobilized gluconolactonase and glucose oxidaseAnalytica Chimica Acta, 1988
- Evaluating Clinical Accuracy of Systems for Self-Monitoring of Blood GlucoseDiabetes Care, 1987
- Design of ion-implanted MOSFET's with very small physical dimensionsIEEE Journal of Solid-State Circuits, 1974
- Normalized thermionic-field (T-F) emission in metal-semiconductor (Schottky) barriersSolid-State Electronics, 1969