Dhrubajyoti Sarma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Dhrubajyoti Sarma has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Sibasish Dutta
Tezpur University
3 shared publications Pabitra Nath
Department of PhysicsApplied Photonics and Nanophtonics Laboratory, Tezpur University, Tezpur, India
2 shared publications- Santanu Sharma
Tezpur University
2 shared publications Tapas Medhi
Department of Molecular Biology and Biotechnology, Tezpur University, Tezpur, India
2 shared publicationsAmal Chandra Kataki
Dr B Borooah Cancer Institute
1 shared publicationAnupam Sarma
Department of Oncopathology, Dr B Borooah Cancer Institute
1 shared publication
Latest Publications
- Open Access
SARS-CoV-2 infection risk in COVISHIELD (AstraZeneca-SII) Vaccinated Healthcare Workers in a Tertiary Cancer Care Centre of North-East India
COVID-19 vaccination of Healthcare workers and vulnerable groups remain priority in containing the spread of SARS-CoV-2 infection and health complications arising post COVID-19. In India, COVISHIELD is the major part of COVID-19 vaccination drive. post-vaccination SARS-CoV-2 infection risk and its impact on severity as well as mortality need to be assessed in vaccinated population. The study included 350 COVISHIELD vaccinated HCWs in tertiary cancer care centre of North-East India. A total of 16 symptomatic HCWs (4.57%) were confirmed as SARS-CoV-2 positive. Among SARS-CoV-2 positive FV HCWs none were positive within 14 days, 13.33 % within 15 to 30 days, 53.33% within 30 to 45 days, and 33.33% after 45 or more days. None of the SARS-CoV-2 positive HCWs required oxygen support or hospitalisation. We also found that 66.67% FV HCWs (n=10) had Ct values below 20, 20% (n=3) had Ct values in between 20-25 and 13.33% (n=2) had Ct values in between 30 to 35. In North-East India COVISHIELD FV HCWs HCW,SARS-CoV-2 infection and COVID-19 symptoms were mild. Majority of FV HCWs have RT-PCR COVID-19 positive Ct Value was below 20. SARS-CoV-2 infection occurred mostly after 15 days to 45 days or more post vaccination.
Open AccessSARS-CoV-2 infection risk in COVISHIELD (AstraZeneca-SII) Vaccinated Healthcare Workers in a Tertiary Cancer Care Centre of North-East India
COVID-19 vaccination of Healthcare workers and vulnerable groups remain priority in containing the spread of SARS-CoV-2 infection and health complications arising post COVID-19. In India, COVISHIELD is the major part of COVID-19 vaccination drive. post-vaccination SARS-CoV-2 infection risk and its impact on severity as well as mortality need to be assessed in vaccinated population. The study included 350 COVISHIELD vaccinated HCWs in tertiary cancer care centre of North-East India. A total of 16 symptomatic HCWs (4.57%) were confirmed as SARS-CoV-2 positive. Among SARS-CoV-2 positive FV HCWs none were positive within 14 days, 13.33 % within 15 to 30 days, 53.33% within 30 to 45 days, and 33.33% after 45 or more days. None of the SARS-CoV-2 positive HCWs required oxygen support or hospitalisation. We also found that 66.67% FV HCWs (n=10) had Ct values below 20, 20% (n=3) had Ct values in between 20-25 and 13.33% (n=2) had Ct values in between 30 to 35. In North-East India COVISHIELD FV HCWs HCW,SARS-CoV-2 infection and COVID-19 symptoms were mild. Majority of FV HCWs have RT-PCR COVID-19 positive Ct Value was below 20. SARS-CoV-2 infection occurred mostly after 15 days to 45 days or more post vaccination.
- 7 July 2018
- Published by Taylor & Francis in International Journal of Electronics
- Vol. 105 (11) , 1855-1865
Characterisation of a Schottky ISFET as Hg-MOSFET and as cytochrome P450-ENFET
A cost-effective and simple method is proposed wherein a Schottky ion sensitive field effect transistor (Schottky ISFET)-based sensor is characterised as metal oxide semiconductor and enzyme field effect transistor (ENFET). This technique involves deposition of mercury (Hg) as gate material over the sensing layer mitigating the complexity of fabrication process, thereby eliminating the need of refabricating an identical device. A Schottky-based ISFET simplifies the fabrication process as the requisite for doping of source and drain regions becomes redundant. Steps involved in lithography process for fabricating metal oxide semiconductor field effect transistor (MOSFET) are reduced with the use of liquid metal Hg as gate over layer. Such a device can be transformed back to an ISFET without any additional etching process. Furthermore, the same ISFET device can be utilised as an ENFET when the former is used in conjunction with a biological element. In this work, a Schottky-based ISFET has been characterised as Hg-MOSFET and as cytochrome P450-ENFET. Multiple tests on the device exhibit that the same ISFET sensor can be used both as a MOSFET and an ENFET with good repeatability and versatility without losing its sensitivity.
- 7 July 2018
- Published by Taylor & Francis in International Journal of Electronics
- Vol. 105 (11) , 1855-1865
Characterisation of a Schottky ISFET as Hg-MOSFET and as cytochrome P450-ENFET
A cost-effective and simple method is proposed wherein a Schottky ion sensitive field effect transistor (Schottky ISFET)-based sensor is characterised as metal oxide semiconductor and enzyme field effect transistor (ENFET). This technique involves deposition of mercury (Hg) as gate material over the sensing layer mitigating the complexity of fabrication process, thereby eliminating the need of refabricating an identical device. A Schottky-based ISFET simplifies the fabrication process as the requisite for doping of source and drain regions becomes redundant. Steps involved in lithography process for fabricating metal oxide semiconductor field effect transistor (MOSFET) are reduced with the use of liquid metal Hg as gate over layer. Such a device can be transformed back to an ISFET without any additional etching process. Furthermore, the same ISFET device can be utilised as an ENFET when the former is used in conjunction with a biological element. In this work, a Schottky-based ISFET has been characterised as Hg-MOSFET and as cytochrome P450-ENFET. Multiple tests on the device exhibit that the same ISFET sensor can be used both as a MOSFET and an ENFET with good repeatability and versatility without losing its sensitivity.
- 15 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 18 (15) , 6059-6069
Use of Cytochrome P450 Enzyme Isolated From Bacillus Stratosphericus sp. as Recognition Element in Designing Schottky-Based ISFET Biosensor for Hydrocarbon Detection
Cytochrome P450 enzyme isolated from an extremophile Bacillus Stratosphericus sp. was used as the recognition element for an ion-sensitive field effect transistor (ISFET)-based biosensor. The fabricated ISFET is Schottky-based and has silicon dioxide as a sensing layer. The cytochrome P450 component in its present purified form (pH-7.2) in 5% agarose was laid over the SiO2 gate to examine its capability of generating electronic response in the presence of n-hexadecane and reduced nicotinamide adenine dinucleotide phosphate. The partially purified preparation was obtained from the lysozyme treated spheroplast via ion exchange chromatography followed by the gel filtration chromatography. The variation of potential difference between the gate and the source with respect to pH for the bare ISFET and the variation of gate and source potential difference with respect to the concentration of the measurand at constant current have been recorded for analyses. The observed correlation showed good repeatability of the sensor output suggesting a potential functional sensing device for hydrocarbon detection. The sensitivity parameters for the device have been determined to be 50.65 mV/pH and 54.34 mV/molar for the bare ISFET and enzyme field-effect transistor, respectively.
- 15 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 18 (15) , 6059-6069
Use of Cytochrome P450 Enzyme Isolated From Bacillus Stratosphericus sp. as Recognition Element in Designing Schottky-Based ISFET Biosensor for Hydrocarbon Detection
Cytochrome P450 enzyme isolated from an extremophile Bacillus Stratosphericus sp. was used as the recognition element for an ion-sensitive field effect transistor (ISFET)-based biosensor. The fabricated ISFET is Schottky-based and has silicon dioxide as a sensing layer. The cytochrome P450 component in its present purified form (pH-7.2) in 5% agarose was laid over the SiO2 gate to examine its capability of generating electronic response in the presence of n-hexadecane and reduced nicotinamide adenine dinucleotide phosphate. The partially purified preparation was obtained from the lysozyme treated spheroplast via ion exchange chromatography followed by the gel filtration chromatography. The variation of potential difference between the gate and the source with respect to pH for the bare ISFET and the variation of gate and source potential difference with respect to the concentration of the measurand at constant current have been recorded for analyses. The observed correlation showed good repeatability of the sensor output suggesting a potential functional sensing device for hydrocarbon detection. The sensitivity parameters for the device have been determined to be 50.65 mV/pH and 54.34 mV/molar for the bare ISFET and enzyme field-effect transistor, respectively.
- 31 May 2016
- Published by Wiley in Journal of Biophotonics
- Vol. 10 (5) , 623-633
Protein, enzyme and carbohydrate quantification using smartphone through colorimetric digitization technique
In this paper the utilization of smartphone as a detection platform for colorimetric quantification of biological macromolecules has been demonstrated. Using V‐channel of HSV color space, the quantification of BSA protein, catalase enzyme and carbohydrate (using D‐glucose) have been successfully investigated. A custom designed android application has been developed for estimating the total concentration of biological macromolecules. The results have been compared with that of a standard spectrophotometer which is generally used for colorimetric quantification in laboratory settings by measuring its absorbance at a specific wavelength. The results obtained with the designed sensor is found to be similar when compared with the spectrophotometer data. The designed sensor is low cost, robust and we envision that it could promote diverse fields of bio‐analytical investigations. Schematic illustration of the smartphone sensing mechanism for colorimetric analysis of biomolecular samples. magnified image Schematic illustration of the smartphone sensing mechanism for colorimetric analysis of biomolecular samples.
- 31 May 2016
- Published by Wiley in Journal of Biophotonics
- Vol. 10 (5) , 623-633
Protein, enzyme and carbohydrate quantification using smartphone through colorimetric digitization technique
In this paper the utilization of smartphone as a detection platform for colorimetric quantification of biological macromolecules has been demonstrated. Using V‐channel of HSV color space, the quantification of BSA protein, catalase enzyme and carbohydrate (using D‐glucose) have been successfully investigated. A custom designed android application has been developed for estimating the total concentration of biological macromolecules. The results have been compared with that of a standard spectrophotometer which is generally used for colorimetric quantification in laboratory settings by measuring its absorbance at a specific wavelength. The results obtained with the designed sensor is found to be similar when compared with the spectrophotometer data. The designed sensor is low cost, robust and we envision that it could promote diverse fields of bio‐analytical investigations. Schematic illustration of the smartphone sensing mechanism for colorimetric analysis of biomolecular samples. magnified image Schematic illustration of the smartphone sensing mechanism for colorimetric analysis of biomolecular samples.
- 25 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 27 (22) , 2363-2366
Dye-Assisted pH Sensing Using a Smartphone
We report the working of a smartphone-based optical sensor for the measurement of pH level of colorless aqueous media. By integrating readily available laboratory optical components to the camera of the smartphone, we convert the smartphone into a visible spectrophotometer with spectral resolution of 0.345 nm/pixel. Evanescent light signal from the designed optical sensing setup is allowed to interact with a pH sensitive dye sample. The transmitted light signal from the sensing region is then captured by the camera of the smartphone in the form of modulated visible image spectrum. The designed sensor can detect change in pH level of medium with a resolution of 0.12 pH unit within range of 6-8 pH unit. We evaluate the repeatability of our sensor for eight consecutive trials and obtained a standard deviation $\sim 0.015$ in the transmission intensity within range of 6-8 pH units. We envision that our designed sensing technique could emerge as a low cost, portable, and robust pH sensor that has the ability to measure pH level of colorless aqueous medium with good accuracy and repeatability.- 25 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 27 (22) , 2363-2366
Dye-Assisted pH Sensing Using a Smartphone
We report the working of a smartphone-based optical sensor for the measurement of pH level of colorless aqueous media. By integrating readily available laboratory optical components to the camera of the smartphone, we convert the smartphone into a visible spectrophotometer with spectral resolution of 0.345 nm/pixel. Evanescent light signal from the designed optical sensing setup is allowed to interact with a pH sensitive dye sample. The transmitted light signal from the sensing region is then captured by the camera of the smartphone in the form of modulated visible image spectrum. The designed sensor can detect change in pH level of medium with a resolution of 0.12 pH unit within range of 6-8 pH unit. We evaluate the repeatability of our sensor for eight consecutive trials and obtained a standard deviation $\sim 0.015$ in the transmission intensity within range of 6-8 pH units. We envision that our designed sensing technique could emerge as a low cost, portable, and robust pH sensor that has the ability to measure pH level of colorless aqueous medium with good accuracy and repeatability.- Open Access
- 1 May 2015
- Published by AIP Publishing in AIP Advances
- Vol. 5 (5) , 057151
Ground and river water quality monitoring using a smartphone-based pH sensor
We report here the working of a compact and handheld smartphone-based pH sensor for monitoring of ground and river water quality. Using simple laboratory optical components and the camera of the smartphone, we develop a compact spectrophotometer which is operational in the wavelength range of 400-700 nm and having spectral resolution of 0.305 nm/pixel for our equipment. The sensor measures variations in optical absorption band of pH sensitive dye sample in different pH solutions. The transmission image spectra through a transmission grating gets captured by the smartphone, and subsequently converted into intensity vs. wavelengths. Using the designed sensor, we measure water quality of ground water and river water from different locations in Assam and the results are found to be reliable when compared with the standard spectrophotometer tool. The overall cost involved for development of the sensor is relatively low. We envision that the designed sensing technique could emerge as an inexpensive, compact and portable pH sensor that would be useful for in-field applications.
- 1 May 2015
- Published by AIP Publishing in AIP Advances
- Vol. 5 (5) , 057151
Open AccessGround and river water quality monitoring using a smartphone-based pH sensor
We report here the working of a compact and handheld smartphone-based pH sensor for monitoring of ground and river water quality. Using simple laboratory optical components and the camera of the smartphone, we develop a compact spectrophotometer which is operational in the wavelength range of 400-700 nm and having spectral resolution of 0.305 nm/pixel for our equipment. The sensor measures variations in optical absorption band of pH sensitive dye sample in different pH solutions. The transmission image spectra through a transmission grating gets captured by the smartphone, and subsequently converted into intensity vs. wavelengths. Using the designed sensor, we measure water quality of ground water and river water from different locations in Assam and the results are found to be reliable when compared with the standard spectrophotometer tool. The overall cost involved for development of the sensor is relatively low. We envision that the designed sensing technique could emerge as an inexpensive, compact and portable pH sensor that would be useful for in-field applications.
- 1 January 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Modeling the transient and steady state behaviour of a glucose oxidase based enzyme field effect transistor
Removed.
- 1 January 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Modeling the transient and steady state behaviour of a glucose oxidase based enzyme field effect transistor
Removed.